1. Introdución
This manual provides essential instructions for the safe and effective use of your ExpertPower 12V 4 AMP Sealed Lead Acid Battery Charger, Model BLMCH12_4. This device is designed to charge and maintain 12V Valve-Regulated Lead Acid (VRLA) batteries, including Absorbent Glass Mat (AGM) and Gel battery types, with capacities ranging from 20 to 50 Amphoras anteriores (AH).
Please read this manual thoroughly before operating the charger to ensure proper function and to prevent damage to the charger or battery.
2. Instrucións de seguridade
ADVERTENCIA: O incumprimento destas instrucións de seguridade pode provocar descargas eléctricas, incendios ou lesións graves.
- Dry Location Use Only: This charger is designed for indoor use in dry environments. Do not expose it to rain, moisture, or wet conditions.
- Risco de descarga eléctrica: Non abra o cargador casing. There are no user-serviceable parts inside. Opening the unit voids the warranty and poses a risk of electric shock.
- Desconectar despois do uso: Always unplug the charger from the AC outlet after each use and before making or breaking connections to the battery.
- Ventilación: Asegúrese de que haxa unha ventilación axeitada arredor do cargador durante o funcionamento. Non cubra o cargador.
- Tipo de batería: This charger is specifically designed for 12V VRLA (AGM and GEL) batteries. Do not attempt to charge other battery types, such as Ni-Cd, Ni-MH, Li-ion, or non-rechargeable batteries, as this may cause explosion or damage.
- Polaridade: Always connect the charger to the battery with correct polarity (red to positive, black to negative). Reverse polarity can damage the charger and battery.
- Nenos e animais: Manteña o cargador e a batería fóra do alcance dos nenos e das mascotas.
- Unidade danada: Do not operate the charger if it has been dropped, damaged, or if the power cord or clips are compromised. Contact ExpertPower support for assistance.
3. Contido do paquete
Ao desembalar, comproba que todos os artigos estean presentes e sen danos:
- ExpertPower 12V 4 AMP Unidade de carga de batería
- Cable de alimentación de CA
- Battery Connection Cables with Alligator Clips

Image 1: ExpertPower 12V 4 AMP Battery Charger showing the main unit, AC power cord, and battery connection cables with red and black alligator clips.
4. Produto rematadoview
The ExpertPower 12V 4 AMP Battery Charger features a compact design with an integrated LED indicator for charging status.

Imaxe 2: Primeiro plano view of the charger's label, detailing input/output specifications and LED indications.
Indicador LED:
- VERMELLO: Indicates the battery is currently charging.
- VERDE: Indicates the battery is fully charged and the charger has switched to float maintenance mode.
5. Configuración e conexión
- Prepare a batería: Asegúrate de que os terminais da batería estean limpos e libres de corrosión.
- Conectar á batería:
- Conecta o VERMELLO pinza de cocodrilo á batería POSITIVO (+) terminal.
- Conecta o NEGRO pinza de cocodrilo á batería NEGATIVA (-) terminal.
Ensure a secure connection. Do not allow the clips to touch each other once connected to the battery.
- Conectar á enerxía: Plug the charger's AC power cord into a standard 100-240V AC wall outlet.
- Verificar a conexión: Once plugged in, the LED indicator on the charger should illuminate. If the battery requires charging, the LED will be VERMELLO.

Image 3: The ExpertPower charger with its AC plug and battery clips, illustrating the connection points.
6. Instrucións de funcionamento
The ExpertPower 12V 4 AMP Smart Charger is designed for automatic operation, providing a safe and efficient charging process.
- Ciclo de carga: When connected correctly and powered, the charger will automatically begin charging the battery. The LED indicator will display VERMELLO during the active charging phase.
- Indicación de carga completa: Once the battery reaches a full charge, the charger will automatically switch from the full charge mode to a float charging mode. The LED indicator will turn VERDE to signify that the battery is fully charged and is now being maintained.
- Mantemento do flotador: The float charging mode maintains the battery at its proper storage voltage without overcharging, preventing damage and extending battery life. You can leave the charger connected for extended periods to keep the battery optimally charged.
7. Mantemento
Proper care ensures the longevity and reliability of your ExpertPower charger.
- Limpeza: Disconnect the charger from both the AC outlet and the battery before cleaning. Use a dry, soft cloth to wipe the exterior. Do not use liquid cleaners or solvents.
- Almacenamento: Store the charger in a cool, dry place when not in use. Keep cables neatly coiled to prevent damage.
- Inspección: Periodically inspect the charger, power cord, and alligator clips for any signs of damage or wear. Do not use if any damage is observed.
- Maintenance Plus Feature: This charger is designed to keep the battery fully charged indefinitely without overcharging, thanks to its automatic float charging mode.
8 Solución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| O indicador LED non se acende. | No AC power; Loose battery connection; Severely discharged battery (below minimum voltage). | Check AC outlet and power cord connection. Ensure battery clips are securely attached with correct polarity. If battery is extremely low, it may not register; try a different battery to test charger. |
| LED indicator remains GREEN when connected to a discharged battery. | Battery is already fully charged; Faulty battery; Incorrect connection. | Confirm the battery actually needs charging. Recheck connections for correct polarity. Test the battery with a voltmeter to confirm its state. If the battery is below 10V, it might be too deeply discharged for the charger to initiate charging. |
| LED indicator remains RED for an extended period. | Battery is large or deeply discharged; Faulty battery. | Charging time varies with battery size and discharge level. Allow sufficient time. If charging takes excessively long or never turns green, the battery may be faulty and unable to hold a charge. |
| O cargador quéntase durante o funcionamento. | Funcionamento normal. | It is normal for the charger to become warm during charging. Ensure adequate ventilation and do not cover the unit. If it becomes excessively hot or emits smoke/odor, disconnect immediately. |
9. Especificacións
- Modelo: BLMCH12_4
- Entrada: 100-240 V CA, 50-60 Hz, 1.0 A
- Saída: 12.0 V CC, 4.0 A
- Tipos de batería compatibles: 12V VRLA (AGM and GEL)
- Capacidade recomendada da batería: 20-50 AH (max 60AH)
- Dimensións do produto: 4.7 x 2.3 x 1.5 polgadas
- Peso do artigo: Aproximadamente 11 onzas
10. Garantía e soporte
ExpertPower products are manufactured to high-quality standards. For warranty information, technical support, or service inquiries, please contact ExpertPower directly. Keep your purchase receipt as proof of purchase.
For more information, visit the official ExpertPower websitio ou póñase en contacto co seu departamento de atención ao cliente.
ExpertPower é unha marca rexistrada.