Everbilt PC00801G

Everbilt 1/8 HP Automatic Pool Cover Pump PC00801G Instruction Manual

Model: PC00801G

1. Introdución

This manual provides essential instructions for the safe and efficient operation, installation, and maintenance of your Everbilt 1/8 HP Automatic Pool Cover Pump, model PC00801G. Please read this manual thoroughly before use and retain it for future reference. This pump is designed to automatically remove standing water from pool covers and is suitable for various water removal applications.

2. Información importante de seguridade

WARNING: To reduce the risk of electrical shock or injury, always disconnect the pump from the power source before attempting to install or service the pump.

  • This pump should be installed in accordance with the National Electrical Code and all local codes and ordinances.
  • The pump must be connected to a 115V, GFCI protected, 10 AMP fusible ou interruptor automático.
  • Do not use an extension cord to power this pump.
  • This warranty only applies if the pump is installed in accordance with these instructions.
  • Do not pump flammable or explosive liquids. This pump is designed for water removal applications only.
  • Always wear safety glasses when installing or servicing this pump.

3. Contido do paquete

  • Everbilt 1/8 HP Automatic Pool Cover Pump
  • 1 in. NPT Discharge with Garden Hose Adapter
  • User and Care Guide (this manual)
Everbilt 1/8 HP Automatic Pool Cover Pump, garden hose adapter, and user manual

Image: The Everbilt 1/8 HP Automatic Pool Cover Pump, its included garden hose adapter, and the printed user manual.

4. Especificacións

CaracterísticaEspecificación
Potencia (HP)0.125 hp (1/8 HP)
Voltage115 V
Ampera1.8 Amps
Maximum Flow Rate (at 0 ft head)1800 GPH (galóns por hora)
Presión máxima de descarga9.27 psi
Maximum Vertical Lift21 pés
Conexión de descarga1 in. NPT with garden hose adapter
Lonxitude do cable de alimentación25 pés con enchufe GFCI
Dimensións do produto (P x A x A)10.25 polgadas x 10.25 polgadas x 9.25 polgadas
Peso do produto5.28 libras
MaterialPlástico
Garantía2 anos

Gráfico de rendemento

Discharge Head (ft)05101520Maximum Head (ft)
Caudal (GPH)1,8001,5601,20084012021

5. Configuración e instalación

5.1 Colocación

Position the pump on the pool cover in the area where water tends to accumulate. Ensure the pump is stable and upright. The pump's design allows it to sit securely on various pool cover surfaces.

5.2 Discharge Hose Connection

Connect a standard garden hose (not included) to the 1 in. NPT discharge with the provided garden hose adapter. Ensure the hose is routed away from the pool cover to a suitable drainage area, preventing water from returning to the cover or causing other issues.

5.3 Conexión de alimentación

Plug the pump's 25 ft power cord into a standard 115V GFCI-protected outlet. As per safety guidelines, do not use extension cords.

Diagram showing Everbilt pool cover pump installed on a pool cover with water being discharged

Image: An illustration demonstrating the proper placement and operation of the Everbilt pool cover pump on a pool cover, showing water being pumped away.

6. Funcionamento

The Everbilt PC00801G pump features microprocessor-controlled automatic operation. It utilizes probe sensors to detect the presence of water on the pool cover.

6.1 Funcionamento automático

  • When water accumulates on the pool cover and reaches the pump's sensors, the pump will automatically activate to remove the water.
  • The pump will continue to operate until the water level drops below the sensor level, at which point it will automatically shut off.

6.2 Debris and Ice Protection

The unit includes built-in protection against debris or ice locking the impeller, ensuring reliable operation in various conditions. However, regular inspection and cleaning are recommended.

7. Mantemento

7.1 Limpeza regular

Periodically inspect the pump and its intake screen for debris such as leaves, twigs, or other obstructions. Clean any accumulated debris to ensure optimal performance and prevent damage to the impeller. Disconnect power before cleaning.

7.2 Invernización

In freezing conditions, disconnect the pump and store it in a warm, dry place to prevent ice damage. Ensure all water is drained from the pump and hose before storage. Do not allow the pump to freeze with water inside.

8 Solución de problemas

ProblemaCausa posibleSolución
A bomba non acende.No power, GFCI tripped, clogged intake, sensor malfunction.Check power connection, reset GFCI, clear intake, ensure sensors are clean and submerged in water.
A bomba funciona pero non elimina auga.Clogged intake, air lock, discharge hose kinked or blocked.Clear intake, ensure pump is fully submerged, check discharge hose for obstructions.
Pump trips GFCI.Electrical fault, water ingress into pump housing.Disconnect pump immediately. Inspect power cord and pump housing for damage. If damage is suspected, discontinue use and contact customer support.

9. Garantía e soporte

9.1 Información da garantía

This Everbilt pump is covered by a 2-year manufacturer's warranty from the date of purchase. Please retain your proof of purchase for warranty claims.

9.2 Atención ao cliente

For technical assistance, replacement parts, or warranty inquiries, please contact Everbilt customer service. Refer to the contact information provided on the product packaging or the official Everbilt websitio.

UPC: 6948217024072

Documentos relacionados - PC00801G

Preview Guía de uso e coidado da bomba de cuberta de piscina submerxible Everbilt de 1/4 HP
Guía completa para a bomba submerxible para cubertas de piscina Everbilt de 1/4 HP (modelo HDPCP25), que abrangue o rendemento, a seguridade, a instalación, o funcionamento, o mantemento e a resolución de problemas. Aprende a usar e coidar eficazmente a bomba para cubertas de piscina.
Preview Bomba submerxible para cubertas de piscina Everbilt de 1/4 HP: guía de uso e coidado
Guía completa para a bomba de cobertura de piscina submerxible Everbilt de 1/4 HP, que abrangue a instalación, o funcionamento, o mantemento, a seguridade e a resolución de problemas. Aprende a usar e coidar eficazmente a túa bomba de piscina Everbilt.
Preview Guía de instalación de accesorios de impermeabilización Everbilt
Guía completa de instalación para accesorios de impermeabilización Everbilt, que detalla a preparación do subsolo, a creación de xuntas, o selado de esquinas e tubaxes e a aplicación final de tellas para instalacións impermeables.
Preview Everbilt 1/3 HP Submersible Automatic Utility Pump Use and Care Guide
Comprehensive use and care guide for the Everbilt 1/3 HP Submersible Automatic Utility Pump (Model EBAU33). Covers performance, safety, installation, operation, maintenance, and troubleshooting.
Preview Everbilt Variable Speed Pool Pump Use and Care Guide
Comprehensive guide for the Everbilt Variable Speed Pool Pump (PCP10001-VSP, PCP15001-VSP), covering installation, operation, maintenance, troubleshooting, and safety information.
Preview Everbilt 1 HP 4" Submersible Deep Well Pump Quick Start Guide
Quick start information and installation guide for the Everbilt 1 HP 4" submersible deep well pump (Model HDSUB10-102). Includes features, specifications, and installation recommendations.