Goodman HKR-05

Goodman HKR-05 Auxiliary Heat Strip 5Kw User Manual

Model: HKR-05

1. Introdución

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Goodman HKR-05 Auxiliary Heat Strip 5Kw. Please read this manual thoroughly before attempting any installation or service to ensure proper function and to prevent potential hazards.

1.1 Información de seguridade

  • AVISO: Installation and servicing of this equipment must be performed by qualified, experienced technicians. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or death.
  • PERIGO: Disconnect all electrical power to the unit before installing or servicing. Failure to do so may result in electrical shock, injury, or death.
  • Use sempre equipos de protección individual (EPI) adecuados durante a instalación e o mantemento.
  • Asegúrese de que se cumpran todos os códigos eléctricos locais e nacionais durante a instalación.

2. Produto rematadoview

The Goodman HKR-05 is a 5Kw auxiliary electric heat strip designed for use with compatible Goodman HVAC systems. It provides supplemental heating, typically used in conjunction with a heat pump during colder temperatures or as an emergency heat source. The unit features pre-tested, pre-wired components for single-phase models, an electric heat limit control, and rust-resistant nickel chromium heating elements.

Goodman HKR-05 Auxiliary Heat Strip

Figure 1: Goodman HKR-05 Auxiliary Heat Strip. This image shows the compact design of the 5Kw electric heat strip, featuring its electrical connections and heating elements.

2.1 Características principais

  • 5 Kilowatt (Kw) heating capacity.
  • Pre-tested and pre-wired for single-phase applications.
  • Integrated electric heat limit control for safety.
  • Durable, rust-resistant nickel chromium heating elements.
  • Suitable for rooftop or ground-level horizontal installation.
  • Approved for manufactured or modular homes.

3. Especificacións

AtributoValor
Número de modeloHKR-05
Capacidade de calefacción5 Kilowatts (Kw)
FaseFase única
Elementos calefactoresNickel Chromium, Rust Resistant
Características de seguridadeElectric Heat Limit Control
Tipo de instalaciónRooftop or Ground-Level Horizontal
Dimensións (L x W x H)14.5 x 9.5 x 8.25 polgadas
Peso do elemento3.03 libras
Interruptor de circuítoNon incluído
FabricanteGoodman

4. Instalación/Configuración

Installation of the HKR-05 Auxiliary Heat Strip should only be performed by a qualified HVAC technician. Refer to the specific Goodman air handler or furnace installation manual for detailed wiring diagrams and compatibility information. The following steps are general guidelines.

4.1 Comprobacións previas á instalación

  1. Verify that the HKR-05 is compatible with your existing HVAC system.
  2. Ensure the electrical supply matches the requirements of the heat strip (5Kw, single phase).
  3. Confirm that the installation location (e.g., air handler cabinet) has adequate space and proper airflow.
  4. Turn off all power to the HVAC system at the main electrical panel before proceeding.

4.2 Pasos da instalación

  1. Montaxe: Securely mount the HKR-05 heat strip within the designated compartment of the air handler or furnace, following the manufacturer's instructions for the specific HVAC unit. Ensure it is positioned for optimal heat distribution and airflow.
  2. Conexións eléctricas: Connect the pre-wired leads of the heat strip to the corresponding terminals in the HVAC unit's control board or power distribution block. Refer to the wiring diagram provided with your air handler/furnace. Ensure all connections are tight and secure.
  3. Conexión a terra: Ensure the heat strip is properly grounded according to local electrical codes.
  4. Interruptor: Install the appropriate circuit breaker(s) in your electrical panel, sized correctly for a 5Kw electric heater. Note: The HKR-05 does not include a circuit breaker.
  5. Comprobacións finais: Double-check all wiring connections for correctness and security. Ensure no wires are pinched or exposed.

5. Funcionamento

The Goodman HKR-05 Auxiliary Heat Strip operates automatically in conjunction with your HVAC system's thermostat and control board. It is designed to provide supplemental heat when the primary heating source (e.g., heat pump) cannot meet the heating demand, or when the system is set to "Emergency Heat" mode.

5.1 Operación normal

  • When the thermostat calls for heat and the outdoor temperature is below the heat pump's efficient operating range, or if the heat pump cannot maintain the set temperature, the auxiliary heat strip will be energized.
  • The heat strip will cycle on and off as needed to maintain the desired indoor temperature.

5.2 Emergency Heat Mode

  • If your HVAC system has an "Emergency Heat" setting, selecting this mode on your thermostat will typically disable the heat pump and rely solely on the auxiliary heat strip for heating. This mode is generally used if the heat pump is malfunctioning.

Note: Electric auxiliary heat consumes more electricity than a heat pump. Use it judiciously to manage energy costs.

6. Mantemento

Regular maintenance ensures the longevity and efficient operation of your auxiliary heat strip. It is recommended that a qualified technician perform annual inspections and maintenance.

6.1 Recommended Maintenance Tasks

  1. Desconexión de alimentación: Always disconnect all electrical power to the HVAC system at the main electrical panel before performing any maintenance.
  2. Inspección visual: Annually inspect the heating elements for any signs of damage, corrosion, or excessive dust accumulation.
  3. Limpeza: Gently clean any dust or debris from the heating elements and surrounding area using a soft brush or vacuum cleaner. Ensure no foreign objects are lodged within the unit.
  4. Conexións eléctricas: Check all electrical connections for tightness and signs of overheating or corrosion. Tighten any loose connections.
  5. Filtro de ar: Ensure the air filter in your HVAC system is clean and replaced regularly as per your system's recommendations. A dirty filter can restrict airflow and reduce heating efficiency.

7 Solución de problemas

If you experience issues with your Goodman HKR-05 Auxiliary Heat Strip, refer to the following common troubleshooting steps. For complex issues, contact a qualified HVAC technician.

7.1 Problemas comúns e solucións

ProblemaCausa posibleSolución
No heat from auxiliary strip
  • Alimentación apagada
  • Disyuntor disparado
  • Faulty thermostat setting
  • Blown fuse or tripped limit switch
  • Problema de cableado
  • Check main electrical panel for power.
  • Restablecer o interruptor automático.
  • Ensure thermostat is set to "Heat" or "Emergency Heat" and temperature is above ambient.
  • Inspect fuses and limit switches (qualified technician only).
  • Have a qualified technician inspect wiring.
Calor insuficiente
  • Filtro de aire sucio
  • Fluxo de aire restrinxido
  • Undersized unit for space
  • Elemento de calefacción avariado
  • Replace or clean air filter.
  • Check for obstructions in ductwork or vents.
  • Consult with an HVAC professional.
  • Have a qualified technician inspect and replace elements if necessary.
Cheiro a queimado
  • Dust accumulation on elements (common for first use after long period)
  • Compoñentes de sobrequecemento
  • The smell should dissipate quickly. If it persists, turn off power and contact a technician.
  • Immediately turn off power and contact a qualified technician.

8. Garantía e soporte

Goodman products are manufactured to high standards and are typically covered by a limited warranty. Specific warranty terms and conditions may vary. Please refer to the warranty documentation included with your complete HVAC system or contact Goodman customer support for details.

8.1 Atención ao cliente

For technical assistance, warranty claims, or to locate a qualified service technician, please visit the official Goodman website or contact their customer service department. Always provide your model number (HKR-05) and serial number when seeking support.

Goodman Oficial Websitio: www.goodmanmfg.com

Documentos relacionados - HKR-05

Preview Goodman AVPTC**14** Air Handler Installation and Operating Instructions
Detailed installation and operating manual for the Goodman AVPTC**14** Air Handler. Covers safety precautions, installation procedures, electrical wiring, maintenance, troubleshooting, and system configurations.
Preview Especificacións do produto de bomba de calor con sistema dividido Goodman CPLE serie 10 SEER
Especificacións detalladas do produto para a bomba de calor de sistema dividido Goodman CPLE serie 10 SEER. Este documento inclúe información completa sobre as características estándar, a construción do armario, as compatibilidades do controlador de aire e da serpentina, os accesorios dispoñibles, as especificacións detalladas, os datos eléctricos, as dimensións da unidade e as amplas clasificacións de rendemento de refrixeración e calefacción para modelos que van desde 1½ ata 5 toneladas.
Preview Sistema inversor de descarga lateral Goodman SD: climatización eficiente e silenciosa
Descubra o sistema inversor de descarga lateral Goodman SD, que ofrece unha eficiencia enerxética superior, un funcionamento silencioso e unha instalación flexible para un confort óptimo no fogar. Descubra as súas características avanzadas.tage, e especificacións.
Preview Goodman Digital Thermostats for Residential Applications: Features, Specifications, and Accessories
Rematada integralview of Goodman digital thermostats for residential use, detailing features of premium and standard lines, model specifications, and available accessories. Includes models like TSTATG2111, TSTATG3272, TSTATG1100, and more.
Preview Instrucións de instalación de serpentín bidireccional horizontal | Goodman, Daikin, Amana HVAC
Guía de instalación completa para serpentinas de evaporador horizontais bidireccionais fabricadas por Goodman Manufacturing Company, LP, para o seu uso con sistemas HVAC Goodman, Daikin e Amana. Abarca precaucións de seguridade esenciais, comprobacións previas á instalación, detalles da aplicación, fixación de bridas de condutos, tubaxes de drenaxe de condensados, instalación da liña de refrixerante, axustes do caudalímetro e procedementos de limpeza da serpentina interior. Inclúe consellos para a resolución de problemas e información de contacto.
Preview Manual de servizo do aire acondicionado e bomba de calor Goodman R-22 con sistema dividido
Este manual de servizo proporciona información técnica detallada e instrucións para os sistemas de aire acondicionado divididos e as bombas de calor con R-22 das marcas Goodman, Amana e Value. Abarca a identificación do produto, o funcionamento do sistema, a resolución de problemas e os procedementos de mantemento para os técnicos de climatización.