LASCO 24V Heat Only Thermostat

Manual de instrucións do termostato só para calefacción de 24 V de White Rodgers

Model: 24V Heat Only Thermostat

1. Introdución

This manual provides comprehensive instructions for the installation, operation, and maintenance of your White Rodgers 24V Heat Only Thermostat. This device is designed to control heating systems by maintaining a desired temperature within a range of 50 to 90 degrees Fahrenheit (10 to 32 degrees Celsius). Please read these instructions carefully before proceeding with installation or operation to ensure safe and efficient use.

2. Información de seguridade

Observe sempre as seguintes precaucións de seguridade:

  • Risco eléctrico: Disconnect power to the heating system at the main fuse or circuit breaker panel before installing or servicing the thermostat. Failure to do so may result in electrical shock or equipment damage.
  • Voltage Compatibilidade: This thermostat is designed for 24V heating systems only. Do not use it with line voltage (120V or 240V) systems.
  • Instalación profesional: If you are unfamiliar with electrical wiring, it is recommended to have a qualified electrician or HVAC technician install this thermostat.
  • Eliminación axeitada: Dispose of old thermostats and packaging materials according to local regulations.

3. Instalación e configuración

Siga estes pasos para a instalación correcta:

3.1 Localización de montaxe

Install the thermostat on an inside wall, approximately 5 feet (1.5 meters) above the floor. Avoid locations:

  • Near windows, outside doors, or vents.
  • Near heat-generating appliances (e.g., televisions, lamps, refrigerators).
  • In direct sunlight or areas with poor air circulation.

3.2 Cableado

Before wiring, ensure power to the heating system is OFF.

  1. Remove the cover of the old thermostat and note the wire connections. Typically, a heat-only system will have two wires: 'R' (power) and 'W' (heat call).
  2. Disconnect the wires from the old thermostat.
  3. Mount the new White Rodgers thermostat base to the wall using the provided screws.
  4. Connect the 'R' wire to the 'R' terminal and the 'W' wire to the 'W' terminal on the new thermostat. Ensure connections are secure.
  5. Coloque a tapa do termostato.

3.3 Encendido inicial

Restore power to the heating system at the main fuse or circuit breaker panel. The thermostat is now ready for operation.

White Rodgers Heat Only Thermostat with temperature dial and OFF/ON switch

Figura 1: Fronte view of the White Rodgers Heat Only Thermostat. The upper slider controls the OFF/ON function, while the lower slider sets the desired temperature, indicated in both Fahrenheit (50-90) and Celsius (10-32).

4. Instrucións de funcionamento

The White Rodgers Heat Only Thermostat features simple manual controls.

4.1 Control de potencia

The upper slider on the thermostat controls the power to the heating system:

  • Desliza ata DESACTIVADO: Disables the heating system.
  • Desliza ata ON: Enables the heating system to operate based on the set temperature.

4.2 Axustar a temperatura

The lower slider on the thermostat is used to set your desired room temperature:

  1. Ensure the upper slider is set to ON.
  2. Move the lower slider to the desired temperature setting. The scale indicates temperatures in both Fahrenheit (50-90°F) and Celsius (10-32°C).
  3. The heating system will activate when the room temperature falls below your set point and will turn off when the room temperature reaches or exceeds your set point.

5. Mantemento

This thermostat requires minimal maintenance.

  • Limpeza: Limpe periodicamente o exterior do termostato cun pano suave eamp pano. Non use produtos de limpeza ou disolventes abrasivos.
  • Eliminación de po: Gently remove any dust accumulation from the vents or internal components using a soft brush or compressed air. Ensure power is off before cleaning internal components.
  • This model does not require battery replacement as it is a mechanical, 24V wired thermostat.

6 Solución de problemas

If you encounter issues with your thermostat, refer to the following table:

ProblemaCausa posibleSolución
Sen calor
  • Thermostat set to OFF.
  • A temperatura definida demasiado baixa.
  • Fusible fundido ou interruptor automático.
  • Cableado solto.
  • Avaría do sistema de calefacción.
  • Set thermostat to ON.
  • Increase set temperature above room temperature.
  • Check and replace fuse or reset breaker.
  • Check wiring connections (ensure power is OFF).
  • Contact an HVAC technician.
Lectura de temperatura inexacta
  • Localización do termostato afectada por correntes de aire ou fontes de calor.
  • Acumulación de po.
  • Relocate thermostat if possible, or shield from drafts/heat sources.
  • Clean thermostat (ensure power is OFF).
Heating system runs continuously
  • Termostato demasiado alto.
  • Mal funcionamento do termostato.
  • Temperatura fixada máis baixa.
  • If problem persists, contact an HVAC technician.

7. Especificacións

  • Marca: White Rodgers (Manufactured by LASCO)
  • Modelo: 24V Heat Only Thermostat
  • Voltage: 24 voltios
  • Actual: 1.2 Amps
  • Rango de temperatura: De 50 a 90 °C (10 a 32 °F)
  • Tipo de visualización: Manual Slider
  • Tipo de control: Button Control (Slider)
  • Retroiluminación: Non
  • Dimensións: Approximately 20 x 7 x 8.8 inches (Product packaging dimensions, actual unit smaller)
  • Peso do artigo: 6.4 onzas
  • UPC: 786710545658

8. Garantía e soporte

Specific warranty information for this White Rodgers thermostat is not provided in the product details. For warranty claims or technical support, please refer to the contact information provided with your purchase or visit the official White Rodgers websitio. Garde o comprobante de compra para calquera consulta relacionada coa garantía.

Documentos relacionados - 24V Heat Only Thermostat

Preview Larsen Supply Co. Ceramic Stems Catalog
Comprehensive catalog of ceramic faucet stems and related repair parts from Larsen Supply Co. (LASCO), featuring detailed specifications, model numbers, and compatibility information for various brands.
Preview Termostato programable Braeburn 2020NC: características e especificacións
Información detallada sobre os sinxelos de Braeburn 2020NCtagTermostato programable convencional ou de bomba de calor para calefacción/refrixeración, incluíndo características, especificacións arquitectónicas e do produto e compatibilidade.
Preview Instrucións de instalación do termostato de bomba de calor non programable White Rodgers 1F79
Guía completa de instalación para o termostato da bomba de calor non programable White Rodgers 1F79, que abrangue a fiación, a montaxe e o funcionamento dos sistemas de calefacción e aire acondicionado.
Preview Branco Rodgers Azul Individual 1/1 StagInstrucións de instalación e funcionamento do termostato electrónico
Este documento proporciona instrucións de instalación e funcionamento para o White Rodgers Blue Single 1/1 StagTermostato e, modelos 1F80-0471 e 1F86-0471. Abarca aplicacións, especificacións, pasos de instalación, funcionamento do termostato, programación e resolución de problemas.
Preview White-Rodgers 1F95-0671 Universal Thermostat Installation and Operation Guide
Comprehensive installation and operating instructions for the White-Rodgers 1F95-0671 Universal Thermostat. Learn about its features, applications, specifications, wiring, programming, and troubleshooting.
Preview Guía de instalación e usuario do termostato White Rodgers 1F95EZ-0671
Guía completa de instalación, configuración e usuario do termostato White Rodgers 1F95EZ-0671. Aprende a instalar, conectar, programar e solucionar problemas do teu termostato para un control óptimo da calefacción e a refrixeración.