Yellow Jacket 16260

Yellow Jacket 16260 Plus II 3/8" Heavy Duty Charging Hose User Manual

Modelo: 16260

1. Introdución

This manual provides essential instructions for the safe and effective use, setup, maintenance, and troubleshooting of your Yellow Jacket 16260 Plus II 3/8" Heavy Duty Charging Hose. Please read this manual thoroughly before operating the product to ensure proper function and longevity.

2. Produto rematadoview

The Yellow Jacket 16260 Plus II is a heavy-duty charging hose designed for various industrial and HVAC applications, particularly for vacuum and charging tasks. Its 3/8" diameter allows for faster vacuum pulling compared to standard 1/4" hoses.

Yellow Jacket 16260 Plus II 3/8 inch Heavy Duty Charging Hose with brass fittings

An image showing the Yellow Jacket 16260 Plus II 3/8 inch Heavy Duty Charging Hose. The hose is black with 'YELLOW JACKET' printed on it, and features brass flare fittings on both ends, one with a knurlagarre ed.

3. Información de seguridade

Always adhere to the following safety guidelines when using the charging hose:

4. Configuración

Follow these steps to properly set up your charging hose:

  1. Inspect the Hose: Before each use, visually inspect the entire length of the hose and its fittings for any signs of wear, cracks, cuts, or damage. Ensure the flare connections are clean and free of debris.
  2. Conectar ao equipo:
    • Connect the 3/8" flare end of the hose to the appropriate port on your vacuum pump or manifold gauge set.
    • Connect the 1/4" flare end of the hose to the system port (e.g., service port on an HVAC/R system) or another component as required for your application.
  3. Conexións seguras: Hand-tighten all connections, then use a wrench to tighten them an additional quarter to half turn to ensure a leak-free seal. Do not overtighten, as this can damage the flare fittings.
  4. Compatibilidade do sistema: Ensure the hose is compatible with the refrigerants or gases being used and that the pressure ratings of all connected equipment meet or exceed the system's operating pressure.

5. Instrucións de funcionamento

This hose is primarily used for vacuuming and charging refrigeration and air conditioning systems. Always refer to the specific instructions for your vacuum pump, manifold gauge set, and the system being serviced.

  1. Para aspirar:
    • Ensure all connections are secure as described in the "Setup" section.
    • Open the appropriate valves on your manifold gauge set to allow the vacuum pump to pull a vacuum through the hose and into the system.
    • Monitor the vacuum level using a vacuum gauge. The 3/8" diameter of this hose facilitates faster evacuation.
    • Once the desired vacuum is achieved, close the manifold valves and turn off the vacuum pump.
  2. Para cargar:
    • After vacuuming, connect the charging hose to the refrigerant cylinder and the system's service port via your manifold gauge set.
    • Purge air from the hose by slightly cracking the valve on the refrigerant cylinder and then the manifold valve, allowing a small amount of refrigerant to escape before fully opening.
    • Carefully open the manifold valves to allow refrigerant to flow into the system. Follow the manufacturer's guidelines for the specific system being charged.
    • Monitor the charge amount using a scale or by observing system pressures.
  3. Desconexión:
    • Always ensure the system is depressurized or isolated before disconnecting the hose.
    • Slowly loosen the fittings to release any residual pressure, then fully disconnect.

6. Mantemento

Proper maintenance ensures the longevity and reliable performance of your charging hose.

7 Solución de problemas

If you encounter issues while using your charging hose, consider the following:

8. Especificacións

CaracterísticaDetalle
Número de modelo16260
Diámetro da mangueira3/8"
Accesorios3/8" Flare x 1/4" Flare, 45 Degree
Lonxitude60 polgadas (5 pés)
MaterialGoma
Temperatura de funcionamento-22 °F a 176 °F (-30 °C a 80 °C)
Presión máxima de traballo600 psi
Minimum Burst Pressure3000 psi
Raio de curvatura mínimo8 polgadas
Peso do elemento1.14 libras

9. Garantía e soporte

For information regarding warranty coverage, technical support, or replacement parts for your Yellow Jacket 16260 Plus II Heavy Duty Charging Hose, please contact Yellow Jacket customer service or visit their official websitio. Conserve o recibo de compra para reclamacións de garantía.

Fabricante: Fotronic Corporation

Documentos relacionados - 16260

Preview Yellow Jacket P51-870 TITAN Digital Manifold Quick Start Guide
A quick start guide for the Yellow Jacket P51-870 TITAN Digital Manifold, covering operation modes, settings, and data management.
Preview Yellow Jacket BULLET®DC Vacuum Pump Operation and Maintenance Manual
Comprehensive operation and maintenance manual for the Yellow Jacket BULLET®DC Vacuum Pump, covering features, setup, troubleshooting, diagnostics, and replacement parts for models 93870, 93872, 93873, 93874, and 93877.
Preview Yellow Jacket Omni Digital Vacuum Gauge Operating Instructions
Comprehensive guide to operating the Yellow Jacket Omni Digital Vacuum Gauge (model 69020), detailing setup, button functions, display readings, and setting adjustments for accurate vacuum measurement.
Preview YJACK MANO™ Dual Port Manometer Quick Start Guide | YELLOW JACKET 67068
Quick start guide for the YELLOW JACKET YJACK MANO™ Dual Port Manometer (Model 67068), featuring Bluetooth® sensing technology. Learn how to power on, connect, view static pressure readings, use the YJACK VIEW™ app, and understand measurement ranges for HVAC applications.
Preview YELLOW JACKET YJACK® Series Bluetooth® Sensing Technology User Manual & Product Guide Rev. C
This comprehensive user manual and product guide for the YELLOW JACKET® YJACK® Series Bluetooth® Sensing devices details their advanced features, integration with the P51-870 TITAN® Digital Manifold and YJACK VIEW® app, and specifications for HVAC/R professionals.
Preview Yellow Jacket 3 Ton Super-Duty Jack Owner's Manual (Model 56647)
Comprehensive owner's manual for the Yellow Jacket 3 Ton Super-Duty Jack (Model 56647), covering safety, operation, assembly, maintenance, troubleshooting, and warranty information. Learn how to safely use and maintain your hydraulic jack.