1. Introdución
This manual provides essential information for the safe and efficient operation, installation, and maintenance of your Everbilt 1-1/2 Hp Thermoplastic Sprinkler Pump. This high-capacity pump is engineered to boost water pressure from city water sources or draw water from lakes and streams for various sprinkling and irrigation applications. It features a robust 1-1/2 HP dual voltage motor and a corrosion-resistant thermoplastic construction, ensuring durability and reliable performance. The pump is self-priming after its initial fill with water, simplifying setup.

Image 1.1: The Everbilt 1-1/2 Hp Thermoplastic Sprinkler Pump, showcasing its compact design and durable thermoplastic housing.
2. Información de seguridade
Lea e comprenda todos os avisos e instrucións de seguridade antes de instalar ou facer funcionar esta bomba. O incumprimento destas instrucións pode provocar descargas eléctricas, incendios, lesións graves ou a morte.
- Seguridade eléctrica: Always disconnect power before servicing the pump. Ensure the pump is properly grounded. All electrical wiring should be performed by a qualified electrician and comply with local codes. Do not operate the pump with a damaged cord or plug.
- Seguridade na auga: Never run the pump dry, as this can cause severe damage. Protect the pump and plumbing from freezing temperatures to prevent cracking and leaks.
- Seguridade xeral: Wear safety glasses when working with the pump. Keep children and unauthorized persons away from the operating area. Do not use this pump for flammable or corrosive liquids.
3. Contido do paquete
Ao desembalar, comprobe que todos os compoñentes estean presentes e sen danos. O paquete debe conter:
- Everbilt 1-1/2 Hp Thermoplastic Sprinkler Pump (1 unit)
- Manual de usuario (este documento)
4. Configuración
Unha instalación axeitada é crucial para o rendemento e a lonxevidade da bomba.
4.1 Localización
- Install the pump on a firm, level surface to minimize vibration.
- Choose a location that is protected from direct sunlight, rain, and freezing temperatures.
- Ensure adequate ventilation around the motor for cooling.
4.2 Conexións de tubaxes
- Use appropriate pipe sizes for the inlet and outlet to ensure optimal flow and prevent cavitation.
- Apply thread sealant to all pipe connections to prevent air leaks, especially on the suction side.
- Install a foot valve with a strainer on the end of the suction line if drawing water from a lake or stream to prevent debris from entering the pump and to maintain prime.
- Install a check valve on the discharge side if necessary to prevent backflow.
4.3 Conexión eléctrica
- The pump features a dual voltage motor (115V or 230V). Ensure the motor is wired for the correct voltage supply available. Refer to the motor's wiring diagram for specific instructions.
- Connect the pump to a dedicated, properly fused electrical circuit.
- Ensure the pump is properly grounded to prevent electrical shock hazards.
4.4 Cebado da bomba
Before initial operation, the pump must be primed:
- Remove the priming plug located on top of the pump casing.
- Encha a bomba casing completely with water until it overflows.
- Volva colocar o tapón de cebado de forma segura.
- Ensure all valves on the suction and discharge lines are open.
5. Instrucións de funcionamento
Once installed and primed, the pump is ready for operation.
5.1 Arranque da bomba
- Verify that all connections are tight and there are no visible leaks.
- Ensure the suction line is submerged in water (if drawing from a source) and the discharge line is open.
- Turn on the electrical power to the pump. The pump should start and begin moving water.
- Monitor the pump for the first few minutes of operation for any unusual noises or vibrations.
5.2 Parar a bomba
To stop the pump, simply turn off the electrical power supply.
6. Mantemento
Un mantemento regular garante un rendemento óptimo e prolonga a vida útil da bomba.
6.1 Comprobacións periódicas
- Periodically inspect the pump and piping for any signs of leaks, corrosion, or damage.
- Clean any debris from the suction strainer (if applicable) to maintain proper flow.
- Ensure the motor's ventilation openings are clear of obstructions.
6.2 Invernación (para climas fríos)
If the pump will be exposed to freezing temperatures, it must be drained to prevent damage:
- Desconecte a alimentación da bomba.
- Remove the drain plug(s) from the pump casing and any low points in the piping system.
- Deixar que toda a auga escorra por completo.
- Store the pump in a dry, protected area if possible, or ensure all plugs are reinstalled loosely to allow for air circulation.
7 Solución de problemas
Esta sección ofrece solucións a problemas comúns cos que podes atoparte.
| Problema | Causa posible | Solución |
|---|---|---|
| A bomba non arranca | No power; tripped circuit breaker; incorrect wiring; motor issue. | Check power supply and circuit breaker. Verify wiring. Consult a qualified electrician if motor issues are suspected. |
| Baixo caudal ou presión de auga | Pump not primed; air leak in suction line; clogged strainer/impeller; incorrect pipe size. | Re-prime the pump. Check all suction line connections for leaks. Clean strainer and impeller. Ensure appropriate pipe sizing. |
| Pump runs but no water moves | Pump not primed; suction line not submerged; air lock. | Ensure pump is fully primed. Verify suction line is adequately submerged. Bleed air from the system if an air lock is suspected. |
| Ruído ou vibración excesivos | Air in system; loose mounting; worn bearings; cavitation. | Check for air leaks and re-prime. Tighten mounting bolts. If bearings are worn, professional service may be required. Ensure adequate water supply to prevent cavitation. |
| Fugas da bomba | Loose connections; damaged seals/gaskets; cracked casing. | Tighten all pipe connections. Inspect and replace damaged seals or gaskets. If casing is cracked, the pump may need replacement. |
8. Especificacións
Technical details for the Everbilt 1-1/2 Hp Thermoplastic Sprinkler Pump.
- Fabricante: Everbilt
- Número de modelo: EFLS15-HD
- Número de peza: EFLS15-HD
- Cor: Negro
- Estilo: Sobre Terra
- Material: Plástico, Polipropileno (PP)
- Tipo de fonte de alimentación: AC/DC
- Voltage: 115 Volts (AC) / 230 Volts (AC) (Dual Voltage)
- Potencia: 1-1/2 HP
- Capacidade de bombeo: Up to 4020 GPH (Gallons Per Hour)
- Maximum Lifting Height (Suction Depth): Ata 20 pés
- Cantidade do paquete do artigo: 1
- Peso do artigo: 19.5 kg
- Dimensións do produto: 76.2 x 40.64 x 40.64 cm (Lonxitude x Ancho x Alto)
- UPC: 856594003961
- Data de primeira dispoñibilidade: 22 de xuño de 2015
9. Garantía e soporte
For warranty information, technical support, or replacement parts, please contact Everbilt customer service. Keep your purchase receipt as proof of purchase for any warranty claims. Detailed contact information can typically be found on the product packaging or the official Everbilt websitio.