Tektronix AFG1022

Manual do usuario do xerador de funcións arbitrarias Tektronix AFG1022

Model: AFG1022

1. Introdución

The Tektronix AFG1022 Arbitrary Function Generator is a versatile instrument designed for generating various waveforms required in laboratory and testing environments. With a bandwidth of 25 MHz or 60 MHz and dual output channels, it provides an output amplitude ranging from 1 mVpp to 10 Vpp across its full bandwidth. This device offers a comprehensive set of features for waveform generation, making it a valuable tool for a wide range of applications.

As características principais inclúen:

  • Dual-channel operation with 25 MHz bandwidth.
  • Saída amplitude from 1 mVpp to 10 Vpp.
  • 14-bit vertical resolution and 1 µHz frequency resolution.
  • 50 built-in arbitrary waveforms.
  • Support for continuous, modulation, sweep, and burst modes.
  • Dedicated 3.95-inch TFT LCD display for clear visualization.
  • User-friendly front panel and menu navigation.
Fronte view of the Tektronix AFG1022 Arbitrary Function Generator with its display showing waveform settings.
Figura 1.1: Fronte view of the Tektronix AFG1022 Arbitrary Function Generator. This image displays the front panel of the AFG1022, highlighting the large color display, control knobs, function buttons, and output connectors. The display shows settings for sweep time, amplitude, and offset, along with various waveform types like sine, square, ramp, pulse, arbitrary, and noise.

2. Información de seguridade

Before operating the Tektronix AFG1022, please read and understand all safety instructions to prevent injury and avoid damage to the instrument or other connected equipment. This device is designed for use by qualified personnel only.

Precaucións xerais de seguridade:

  • Conexión a terra: Always ensure the instrument is properly grounded. The power cord provided has a three-prong plug for this purpose. Do not defeat the grounding-type plug.
  • Fonte de enerxía: Connect the instrument to a power source that is within the specified voltage range (100-240V AC, 50/60 Hz). Verify the line selector switch on the rear panel is set correctly for your local voltage.
  • Ventilación: Ensure proper ventilation around the instrument. Do not block ventilation openings. Overheating can cause damage.
  • Ambiente: Operate the instrument in a clean, dry environment. Avoid exposure to moisture, extreme temperatures, or corrosive gases.
  • Servizo: Refer all servicing to qualified service personnel. Do not attempt to service the instrument yourself unless you are qualified to do so.
  • Cables e conectores: Use only specified cables and connectors. Ensure all connections are secure before applying power.
  • Limpeza: Desconecte a alimentación antes de limpar. Use un pano suave e seco. Non empregue produtos de limpeza líquidos nin en aerosol.

3. Que hai na caixa

Upon unpacking your Tektronix AFG1022 Arbitrary Function Generator, please verify that all the following items are included:

  • Tektronix AFG1022 Arbitrary Function Generator Unit
  • Declaración de conformidade
  • CD (containing software and documentation)
  • Manual de usuario (este documento)
  • Fuse (2 pieces, spare)
  • Cables (3 pieces, including USB and BNC cables)
  • Certificado de calibración
  • Cable de alimentación

If any items are missing or damaged, please contact your Tektronix supplier or customer support immediately.

4. Configuración

Follow these steps to set up your AFG1022 Arbitrary Function Generator for initial use.

4.1 Desembalaxe e inspección

  1. Carefully remove the instrument and all accessories from the packaging.
  2. Inspect the instrument for any signs of physical damage that may have occurred during transit. If damage is found, contact your supplier.
  3. Retain the original packaging materials for future transport or storage.

4.2 Conexión de alimentación

  1. Locate the power inlet on the rear panel of the AFG1022.
  2. Verifica o Selector de liña o interruptor do panel traseiro está axustado ao volume correctotage for your region (110V AC or 220V AC). Adjust if necessary.
  3. Connect the provided power cord to the instrument's power inlet and then to a grounded AC power outlet.
Traseira view of the Tektronix AFG1022 Arbitrary Function Generator showing input/output ports and power connections.
Figura 4.1: Traseira view of the Tektronix AFG1022. The rear panel shows the Ref Clk Out, Ext Trig/Burst/Fsk In, Ext Mod In, and USB ports. It also includes the AC power inlet with fuse, and a line selector switch for 110V/220V AC operation. A warning about proper grounding is visible.

4.3 Conexión de saídas

  1. Identify the two output channels (Out1 and Out2) on the front panel. These are BNC connectors.
  2. Connect appropriate BNC cables from the desired output channel(s) to your test circuit or device under test.
  3. Ensure the impedance setting on the AFG1022 matches the impedance of your load (typically 50Ω or high impedance).

5. Instrucións de funcionamento

Esta sección ofrece un sobreview of the basic operation of the Tektronix AFG1022. For detailed instructions on specific functions, refer to the comprehensive user manual provided on the included CD.

5.1 Acendido e pantalla inicial

  1. Prema o botón de acendido situado no panel frontal para acender o instrumento.
  2. The display will show the Tektronix logo and then transition to the main waveform generation interface.

5.2 Xeración básica de formas de onda

The AFG1022 can generate various standard waveforms and arbitrary waveforms.

  • Selecting Waveform Type: Use the dedicated buttons below the display (Sine, Square, Ramp, Pulse, Arb, Noise) to select the desired waveform.
  • Frecuencia de configuración: Use the numeric keypad and the rotary knob to input the desired frequency. The display will update in real-time.
  • Configuración Amplitude and Offset: Axustar o amplitude (Vpp) and DC offset (V) using the corresponding soft keys and the rotary knob.
  • Activación da saída: Preme o On/Off button for Channel 1 (Out1) or Channel 2 (Out2) to enable the waveform output. The button will illuminate when the output is active.
Fronte angulada view of the Tektronix AFG1022 Arbitrary Function Generator on a workbench.
Figura 5.1: Fronte angulada view of the Tektronix AFG1022. This image provides an angled view of the AFG1022 on a workbench, emphasizing its compact design and the clarity of its display. The display shows a sweep time setting of 25 billion seconds, indicating its wide range of capabilities. Various tools and other lab equipment are visible in the background.

5.3 Funcións avanzadas

  • Modulación: Preme o Mod button to access modulation settings (AM, FM, PM, FSK, PWM).
  • Varrer: Configure frequency sweeps by pressing the Varrer tecla de función.
  • Explosión: Generate burst waveforms by pressing the Rebentar tecla de función.
  • Formas de onda arbitrarias: The AFG1022 supports user-defined arbitrary waveforms. Refer to the full manual for instructions on creating and loading custom waveforms.

6. Mantemento

Proper maintenance ensures the longevity and optimal performance of your Tektronix AFG1022.

6.1 Limpeza

  • Always disconnect the power cord before cleaning the instrument.
  • Use a soft, dry cloth to wipe the exterior surfaces. For stubborn dirt, a cloth lightly dampened with mild detergent and water may be used.
  • Do not use abrasive cleaners, solvents, or strong chemicals, as these can damage the plastic parts and labels.
  • Avoid spraying liquids directly onto the instrument.

6.2 Substitución de fusibles

If the instrument does not power on, check the fuse located in the power inlet on the rear panel. Ensure the replacement fuse matches the specified type and rating (e.g., 250V, 2A). Refer to the full manual for detailed instructions on fuse replacement.

6.3 Calibración

For continued accuracy, periodic calibration by qualified service personnel is recommended. Refer to the calibration certificate for the recommended calibration interval.

7 Solución de problemas

This section provides solutions to common issues you might encounter with your AFG1022. If the problem persists, contact Tektronix customer support.

ProblemaCausa posibleSolución
O instrumento non se acende.No power, faulty power cord, blown fuse.Check power cord connection. Verify power outlet. Check and replace fuse if necessary. Ensure line selector is correct.
Sen saída de forma de onda.Output channel not enabled, incorrect amplitude/offset settings, faulty cable, incorrect load impedance.Press the On/Off button for the desired channel. Verify amplitude and offset settings. Check BNC cable connections. Ensure load impedance matches instrument setting.
A pantalla está en branco ou conxelada.Software error, internal fault.Power cycle the instrument (turn off, wait 10 seconds, turn on). If issue persists, contact support.
Incorrect waveform shape/frequency.Incorrect settings, external interference.Double-check all waveform parameters (frequency, amplitude, offset, modulation settings). Ensure proper shielding of cables.

8. Especificacións

The following table lists the key specifications for the Tektronix AFG1022 Arbitrary Function Generator. All specifications are typical unless otherwise noted.

ParámetroValor
Nome do modeloAFG1022
Ancho de banda25 MHz
CanlesDobre canle
Saída Amplititude1 mVpp a 10 Vpp
Resolución vertical14 bits
Resolución de frecuencia1 µHz
Built-in Waveforms50 Arbitrary Waveforms
MostrarLCD TFT de 3.95 polgadas
Fonte de enerxíaElectricity Powered
Voltage100-240V AC (selectable)
Peso do elemento4.9 quilogramos (10.8 libras)
Dimensións do paquete17.2 x 14 x 11.4 polgadas
FabricanteTektronix
Data de primeira dispoñibilidade15 de xullo de 2015

9. Garantía e soporte

Tektronix products are designed for reliability and performance. For specific warranty terms and conditions applicable to your AFG1022, please refer to the warranty information provided with your purchase or visit the official Tektronix websitio.

Atención ao cliente:

If you require technical assistance, have questions about your instrument, or need to arrange for service, please contact Tektronix customer support. Support contact information can typically be found on the Tektronix websitio web ou na documentación incluída co produto.

When contacting support, please have your instrument's model number (AFG1022) and serial number ready. The serial number is located on the rear panel of the instrument.

For the latest information, drivers, software, and additional resources, please visit the official Tektronix websitio: www.tek.com

Documentos relacionados - AFG1022

Preview Tektronix AFG3000 Series: 25 Applications of Arbitrary/Function Generators
Explore 25 practical applications for Tektronix AFG3000 Series Arbitrary/Function Generators, covering embedded systems, RF, automotive, medical, industrial, and research fields. Enhance your electronic testing and design workflows.
Preview Tektronix KickStart Software Datasheet: Accelerate Measurement Efficiency
Explore the Tektronix KickStart software, a powerful PC application designed for quick instrument setup, data visualization, and analysis. Discover its various apps for DMMs, AFGs, data logging, I-V characterization, power supplies, oscilloscopes, battery simulation, and high resistivity measurements. Streamline your testing workflow and gain faster insights into your data.
Preview AWG70001A および AWG70002A 任意波形ジェネレータ インストールおよび安全に関する取扱説明書
Tektronix AWG70001A および AWG70002A 任意波形ジェネレータの設置と安全に関する取扱説明書。セットアップ、安全上の注意、および基本的な操作ガイダンスを網羅しています。
Preview AWG70001A および AWG70002A 任意波形ジェネレータ インストールおよび安全に関する取扱説明書
Tektronix AWG70001A および AWG70002A 任意波形ジェネレータの安全な設置、操作、および保守に関する包括的なガイド。安全上の注意、セットアップ手順、およびデバイス機能の概要を提供します。
Preview Tektronix PPG4001 PatternPro Programmable Pattern Generator User Manual
User manual for the Tektronix PPG4001 PatternPro Programmable Pattern Generator, detailing features, specifications, operation, safety, and remote programming for advanced signal generation.
Preview Tektronix 1410 NTSC Generator Instruction Manual
Comprehensive instruction manual for the Tektronix 1410 NTSC Generator, detailing operation, specifications, installation, theory of operation, maintenance, and troubleshooting for this video test equipment.