Elitech WJL-6000

Elitech WJL-6000S Freon Leak Detector User Manual

Model: WJL-6000S

Marca: Elitech

Introdución

The Elitech WJL-6000S is a highly sensitive halogen refrigerant gas leak detector designed for HVAC systems. It is capable of detecting all halogenated refrigerants, including HFCs, CFCs, HCFCs, and blends such as R22, R134A, R404A, R410A, and R1234YF. This manual provides detailed instructions for the proper setup, operation, and maintenance of your leak detector to ensure accurate and reliable performance.

Elitech WJL-6000S Freon Leak Detector

Figure 1: Elitech WJL-6000S Freon Leak Detector with flexible probe.

Configuración

1. Instalación da batería

The WJL-6000S requires four AAA Lithium Metal batteries (not included). To install the batteries:

  1. Locate the battery compartment on the back of the detector.
  2. Deslice para abrir a tapa da batería.
  3. Insira catro pilas AAA, asegurándose de manter a polaridade correcta (+/-) como se indica no interior do compartimento.
  4. Pecha a tapa da batería de forma segura.
Battery Compartment of Elitech WJL-6000S

Figura 2: Compartimento para pilas AAA.

2. Initial Power On and Calibration

Before first use, or after prolonged storage, allow the detector to warm up and self-calibrate in a clean, refrigerant-free environment.

  1. Turn the sensitivity knob from 'off' to 'on'. The detector will begin a warm-up sequence.
  2. The warm-up time is approximately 6 seconds. The unit will beep to indicate it is ready for use.
  3. Ensure the probe tip is in an area free of refrigerants during this calibration phase to ensure accurate readings.

Video 1: Demonstrates the beeping sound of the WJL-6000 leak detector when it detects a leakage, also shows initial power on and calibration.

Instrucións de funcionamento

1. Adjusting Sensitivity

The WJL-6000S features 7 adjustable sensitivity levels. Turn the knob to select the appropriate sensitivity for your detection needs. Higher sensitivity levels (e.g., 7) are for detecting very small leaks, while lower levels (e.g., 1) are for larger leaks or to avoid false positives in contaminated areas.

Sensitivity Adjustment Knob on Elitech WJL-6000S

Figure 3: Sensitivity adjustment knob.

2. Leak Detection Process

Once calibrated, slowly move the flexible probe tip around suspected leak areas. The detector responds within 3 seconds to the presence of halogenated refrigerants.

  • Indicador sonoro: The ticking sound will increase in frequency and turn into a sharp siren in the presence of a refrigerant leak.
  • Indicador visual: The LED indicator lights will flash increasingly as the concentration of refrigerant increases.
  • Sonda flexible: The 7.9-inch flexible probe allows for easy access to difficult and hard-to-reach areas.
Audible and Visual Alarms of Elitech WJL-6000S

Figure 4: Detector showing audible and visual alarms during operation.

3. Refrigerant Types Detected

The WJL-6000S is designed to detect a wide range of halogenated refrigerants, including:

  • HFCs: R134A, R404A, R410A, R1234YF, R407C, R417A, R507, R23, R508A, R508B, R152a, R32, etc.
  • HCFCs: R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A, etc.
  • CFC: R11, R12, R13, R502, R503, etc.
  • PFCs: PFC-14, PFC-116, PFC-218, etc.
  • HFO: R-1234YF
Types of Halogenated Refrigerants Detected by Elitech WJL-6000S

Figure 5: Comprehensive list of detectable refrigerants.

4. UV Light Functionality

The detector includes a UV light feature, useful for identifying leaks when a fluorescent agent has been added to the refrigerant system. It also functions as a white flashlight for illuminating dark and small spaces.

UV Light and White Flashlight Feature of Elitech WJL-6000S

Figure 6: UV light and white flashlight capabilities.

Mantemento

1. Cleaning the Sensor Tip

To ensure optimal performance and prevent false alarms, keep the sensor tip clean and free from contaminants such as compressor oil, dirt, moisture, or other solvents. Avoid touching the sensor tip with bare hands.

2. Substitución da batería

When the battery indicator shows low power, replace all four AAA batteries following the installation steps in the Setup section.

Resolución de problemas

1. False Alarms or Inconsistent Readings

  • Contaminantes: Ensure the sensor tip is clean and not in contact with any liquids, oils, or dirt.
  • Recalibración: If the ticking tone becomes inconsistent or you suspect false readings, move the detector to a clean, fresh air environment and allow it to recalibrate. Adjust the sensitivity knob to a suitable degree.
  • Airflow Obstruction: Avoid pressing the probe tip directly against surfaces that might block airflow to the sensor, as this can cause false alarms.

2. No Detection

  • Comprobación da batería: Verifique que as baterías estean instaladas correctamente e que teñan a carga suficiente. Substitúaas se é necesario.
  • Configuración da sensibilidade: Ensure the sensitivity is set to an appropriate level for the expected leak size. For very small leaks, use the highest sensitivity setting.
  • Colocación da sonda: Ensure the probe is moved slowly and methodically around the suspected leak area to allow the sensor sufficient time to detect the refrigerant.

Especificacións

CaracterísticaDetalle
MarcaElitech
ModeloWJL-6000S
Fonte de enerxía4 AAA Lithium Metal batteries (not included)
Sensibilidade máxima0.21 oz/yr
Tempo de prequecemento6 segundos
Tempo de resposta3 segundos
Temperatura de traballo0 °C a 52 °C (32 °F a 125.6 °F)
Humidade de funcionamento95% RH (sen condensación)
Lonxitude da sonda7.9 inches (flexible)
Peso do elemento7.2 onzas
Dimensións do produto1.37" D x 1.37" W x 5.9" H
AlarmaAudible, visual
Elitech WJL-6000S Specifications and Dimensions

Figure 7: Detailed specifications and dimensions of the detector.

Garantía e soporte

Elitech provides 24/7 US Technician Support via Email and Phone for any inquiries or issues you may encounter with your WJL-6000S Freon Leak Detector. Please refer to the product packaging or Elitech's official websitio web para obter detalles específicos da garantía e información de contacto.

Documentos relacionados - WJL-6000

Preview Manual de usuario del detector de corona Elitech WJL-6000S
Manual de usuario do detector de corona Elitech WJL-6000S, que proporciona instrucións detalladas sobre o funcionamento, a detección, a resolución de problemas e o mantemento para a detección de fugas de refrixerante en varios sistemas.
Preview Manual de usuario del detector de fugas de refrigerante por infravermellos Elitech ILD Series
Manual de usuario completo para os detectores de fugas de refrixerante por infravermellos da serie Elitech ILD (ILD-100, ILD-200, ILD-300), que abrangue as especificacións, o funcionamento, o mantemento e as características. Aprenda a detectar eficazmente as fugas de refrixerante con este dispositivo avanzado.
Preview Elitech HLD-200 Manual de usuario del detector de fugas halógenas
This user manual provides comprehensive instructions for operating and maintaining the Elitech HLD-200 Halogen Leak Detector. It covers technical specifications, operation procedures, leak detection methods, troubleshooting, and maintenance tips for effective use in refrigeration and HVAC systems.
Preview Manual do usuario do detector de fugas de refrixerante con diodo calefactado Elitech LD-100
Manual de usuario do detector de fugas de refrixerante por díodo calefactado Elitech LD-100, que detalla as súas características, funcionamento e mantemento.
Preview Manual do usuario do detector de fugas por diodos infravermellos e calefactados Elitech IR-200
Manual de usuario completo para o Elitech IR-200, un detector de fugas de dobre sensor con tecnoloxía de infravermellos e díodos calefactados. Coñece as súas especificacións, funcionamento, mantemento e características para detectar fugas de refrixerante.
Preview Manual do usuario do detector de fugas por infravermellos Elitech ILD-100/ILD-200/ILD-300
Manual de usuario para os detectores de fugas de refrixerante por infravermellos da serie Elitech ILD (ILD-100, ILD-200, ILD-300). Ofrece información detallada sobre o funcionamento, as especificacións, as características e o mantemento para unha detección precisa das fugas de refrixerante.