Pedrollo UPm2/4

Pedrollo UPm2/4-GE 1Hp 240V Multi-StagManual do usuario da bomba de auga eléctrica submerxible

Model: UPm2/4 | Brand: Pedrollo

1. Introdución

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump. Please read this manual thoroughly before installation and use, and retain it for future reference.

The Pedrollo UP series of multi-stage submersible pumps features an innovative design that prevents impellers from blocking, even after extended periods of inactivity. This design ensures high efficiency and reliability, making these pumps suitable for clean water applications in domestic, civil, and agricultural settings. Typical uses include water distribution with pressure sets, garden and allotment irrigation, and pressure boosting.

2. Información de seguridade

Always observe the following safety precautions to prevent personal injury and damage to the pump:

  • Asegúrate de que a fonte de alimentación coincida co volume da bombatage requisitos (240V).
  • Desconecte a alimentación antes de realizar calquera traballo de instalación, mantemento ou reparación.
  • Do not operate the pump with damaged cables or if the pump itself is visibly damaged.
  • The pump is designed for clean water only. Do not use it for flammable, corrosive, or abrasive liquids.
  • Ensure proper grounding of the electrical system.
  • Keep children and unauthorized personnel away from the pump's operating area.
  • Do not lift the pump by its electrical cable. Use a rope or chain attached to the pump's lifting eye.

3. Configuración e instalación

Proper installation is crucial for the pump's performance and longevity. Refer to the diagram below for a typical installation setup.

Pedrollo UPm2/4-GE Submersible Pump Installation Diagram and Performance Data

Figura 1: Typical installation diagram, performance curves, and dimensional data for Pedrollo UPm2/4-GE submersible pumps. This image illustrates how the pump should be submerged in a water source, connected to a discharge pipe, and includes technical specifications and performance characteristics.

  • Inmersión: The pump must be fully submerged in clean water. Ensure the water level is always above the pump's intake.
  • Montaxe: Secure the pump using a suitable rope or chain attached to the designated lifting point. Do not let the pump rest directly on the bottom if it's muddy or sandy.
  • Tubo de descarga: Connect a discharge pipe of appropriate diameter to the pump's outlet. Ensure all connections are watertight.
  • Conexión eléctrica: Connect the pump to a 240V power supply with proper grounding and a residual current device (RCD) for safety. Consult a qualified electrician if unsure.
  • Interruptor flotante: If equipped with a float switch (as shown in Figure 1), ensure it can move freely to control the pump's on/off cycles based on water level.

4. Instrucións de funcionamento

Once installed correctly, operating the Pedrollo UPm2/4-GE pump is straightforward:

  • Posta en marcha inicial: Ensure the pump is fully submerged and all connections are secure. Turn on the power supply. The pump will start automatically if the float switch is in the 'on' position (water level high enough).
  • Funcionamento continuo: The pump is designed for continuous operation within its specified limits. Monitor the water level to prevent dry running, especially if not using a float switch.
  • Apagado: To stop the pump, turn off the power supply. If using a float switch, the pump will stop automatically when the water level drops below the minimum operating level.
  • Calidade da auga: The pump is intended for clean water. Pumping water with excessive sediment or debris can damage the impellers and motor.

5. Mantemento

Regular maintenance ensures optimal performance and extends the pump's lifespan. Always disconnect power before maintenance.

  • Limpeza: Periodically inspect the pump's intake screen for blockages from debris. Clean as necessary.
  • Inspección do impulsor: While the pump's design resists blocking, occasional inspection of the impellers for wear or damage is recommended, especially if performance degrades. This typically requires professional service.
  • Inspección de cables: Check the power cable for any signs of damage, cuts, or fraying. Replace immediately if damaged.
  • Invernización: In freezing climates, remove the pump from the water source and store it in a frost-free environment if it will not be used during winter. Drain all water from the pump and pipes.

6 Solución de problemas

Se tes problemas coa bomba, consulta os seguintes problemas e solucións comúns:

ProblemaCausa posibleSolución
A bomba non arrancaNo power; Float switch in 'off' position; Motor overload; Damaged cable.Check power supply and circuit breaker; Ensure float switch is free and water level is sufficient; Reset thermal overload protector (if present); Inspect and replace cable if damaged.
A bomba funciona pero non hai auga ou o caudal é baixoIntake blocked; Air in system; Discharge pipe blocked or kinked; Low water level; Worn impellers.Clean intake screen; Bleed air from the system; Check and clear discharge pipe; Ensure pump is fully submerged; Contact service for impeller inspection.
A bomba para de forma inesperadaOverheating; Low water level (float switch activated); Electrical fault.Allow pump to cool; Check water level; Inspect electrical connections and power supply.

If troubleshooting steps do not resolve the issue, contact a qualified technician or Pedrollo customer support.

7. Especificacións

The following table details the technical specifications for the Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump:

Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump

Figura 2: Fronte view of the Pedrollo UPm2/4-GE Multi-Stage Submersible Electric Water Pump, showcasing its stainless steel body, blue power cable, and orange float switch.

EspecificaciónValor
MarcaPedrollo
Número de modeloUPm2/4 (48SP2120A1)
Poder1 hp
Voltage240 voltios
MaterialAceiro inoxidable
Fonte de enerxíaCable eléctrico
Caudal máximo80 litros por minuto
Altura máxima de elevación62 metros
ASINB018W45YV0

8. Garantía e soporte

Specific warranty details for the Pedrollo UPm2/4-GE pump are not provided in this manual. For warranty information, please refer to the documentation included with your purchase or contact the seller (cemstore) or Pedrollo directly. For technical support or service, please reach out to the authorized Pedrollo service center in your region.

Documentos relacionados - UPm2/4

Preview Pedrollo UP Series Multi-stage Submersible Pumps: Performance, Specifications, and Installation
Detailed information on Pedrollo UP Series multi-stage submersible pumps, including performance range, application limits, construction details, characteristic curves, dimensions, and installation guidelines. Ideal for domestic, civil, and agricultural use.
Preview Istruzioni per l'uso: Pompe Elettriche Pedrollo Serie TOP MULTI
Guida completa alle istruzioni per l'uso, l'installazione, la sicurezza e la manutenzione delle pompe elettriche Pedrollo, incluse le serie TOP MULTI, UP, NK e altre.
Preview Bombas de auga submerxibles automáticas Pedrollo TOP MULTI-TECH e TOP MULTI-EVOTECH - Manual de funcionamento
Este documento proporciona unha guía operativa para os multimerxibles automáticos Pedrollo TOP MULTI-TECH e TOP MULTI-EVOTECH.tagbombas de auga e. Abarca información xeral, funcionamento, proteccións e consellos típicos de instalación.
Preview Manual de funcionamento da bomba de auga sumerxible automática Pedrollo TOP MULTI-TECH / TOP MULTI-EVOTECH
Este documento proporciona instrucións de funcionamento para os multimerxíbeis automáticos Pedrollo TOP MULTI-TECH e TOP MULTI-EVOTECH.tage water pumps. It covers general information, operating principles, installation advice, and protection features for optimal performance and longevity.
Preview Bombas submerxibles automáticas Pedrollo TOP MULTI-TECH: especificacións e rendemento
Especificacións técnicas detalladas, curvas de rendemento, guía de instalación e características da serie de multifunción Pedrollo TOP MULTI-TECHtagBombas submerxibles automáticas, deseñadas para aplicacións de auga limpa.
Preview Pompe Elettrosommergibili Pedrollo: DAVIS, 4-BLOCK, SALI, PRO 100AR - Istruzioni d'Uso
Guida completa alle pompe elettrosommergibili Pedrollo, inclusi i modelli DAVIS, 4-BLOCK, SALI, PRO 100AR, 3SR, 4SR, 4HR, 6SR, 6ST, 6HR, 4PD, 4PS, 6PD, 6PSR. Fornisce dettagli su installazione, uso sicuro, limiti operativi e manutenzione per un efficiente approvvigionamento idrico.