Cooper Lighting SDC15

SDC15-W Skye Fan/Light Control

Model: SDC15 | Brand: Cooper Lighting

Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of your Cooper Lighting SDC15-W Skye Fan/Light Control. Please read all instructions carefully before beginning installation or use to ensure proper function and safety.

Información de seguridade

AVISO: To avoid fire, shock, or death; turn off power at circuit breaker or fuse box and test that the power is off before wiring. This device is intended for installation in accordance with the National Electric Code and local regulations. It is recommended that a qualified electrician perform this installation.

PRECAUCIÓN: For indoor use only. Do not exceed the maximum wattage ou amperage ratings. This device is designed for incandescent light fixtures up to 300W and ceiling fans up to 1.5A. Not for use with fluorescent lights, LED lights, or exhaust fans.

Configuración e instalación

Before installation, ensure the power to the circuit is turned off at the circuit breaker. This control is designed for single-gang wall box installation and supports 3-way circuit configurations.

Instrucións de cableado

  1. Identify the Line (hot), Load (to fan/light), and Ground wires from your wall box.
  2. Connect the green ground wire from the SDC15 to the bare copper or green ground wire in the wall box.
  3. Connect the black wire labeled 'BK' (Common/Line) from the SDC15 to the incoming Line (hot) wire.
  4. Connect the yellow wire labeled 'YL Light' from the SDC15 to the wire leading to your light fixture.
  5. Connect the yellow wire labeled 'YL Fan' from the SDC15 to the wire leading to your ceiling fan.
  6. Secure all wire connections with appropriate wire nuts.
De volta view of the SDC15-W Fan/Light Control showing wiring terminals

Imaxe: Traseira view of the SDC15-W control, illustrating the screw terminals for wiring connections. Labels for 'YL Light', 'BK', 'YL Fan', and 'GND' are visible, indicating connections for light, common/line, fan, and ground respectively. This view is crucial for correct electrical installation.

Lado view of the SDC15-W Fan/Light Control

Imaxe: Side profile of the SDC15-W control, showing its depth and mounting bracket. This view helps in understanding the physical dimensions for fitting into a standard wall box.

Montaxe

  1. Carefully push the wired control into the wall box.
  2. Secure the control to the wall box using the provided mounting screws.
  3. Attach the wall plate (not included) over the control.
  4. Restablecer a enerxía no interruptor automático.

Instrucións de funcionamento

The SDC15-W features two independent slider controls: one for the ceiling fan speed and one for the light dimmer.

Fronte view of the SDC15-W Fan/Light Control

Imaxe: Fronte view of the SDC15-W Fan/Light Control, showcasing the two vertical slider controls. The left slider has a fan icon, and the right slider has a light bulb icon, with an 'OFF' position clearly marked between them. This is the primary user interface for controlling fan speed and light intensity.

Control de velocidade do ventilador

  • To turn the fan ON, slide the left control lever upwards from the 'OFF' position.
  • Slide the lever further upwards to increase fan speed.
  • Slide the lever downwards to decrease fan speed.
  • To turn the fan OFF, slide the lever all the way down to the 'OFF' position.

Control de atenuación de luz

  • To turn the light ON, slide the right control lever upwards from the 'OFF' position.
  • Slide the lever further upwards to increase light brightness.
  • Slide the lever downwards to decrease light brightness.
  • To turn the light OFF, slide the lever all the way down to the 'OFF' position.

Mantemento

The SDC15-W Fan/Light Control requires minimal maintenance. Ensure the power is off before cleaning.

  • Clean the surface of the control with a soft, damp pano. Non use produtos de limpeza ou disolventes abrasivos.
  • Periodically check the mounting screws for tightness.
  • Non hai pezas que o usuario poida reparar no interior. Non intente desmontar a unidade.

Resolución de problemas

ProblemaCausa posibleSolución
Fan/Light does not turn ON.No power to the control; Incorrect wiring; Blown fuse/tripped breaker.Check circuit breaker/fuse. Verify wiring connections. Ensure power is restored.
Fan speed or light brightness does not change.Incorrect wiring; Incompatible fan/light type; Control is faulty.Verify wiring. Ensure fan/light is compatible (incandescent for light, standard ceiling fan for fan). Replace control if necessary.
Fan hums or wobbles.Fan motor incompatibility; Fan balance issue.Ensure fan is compatible with solid-state speed controls. Check fan blade balance.
A luz tremeluza ou zunida.Incompatible bulb type; Loose bulb; Overloaded circuit.Ensure incandescent bulbs are used. Tighten bulb. Reduce total wattage if exceeding 300W.

Especificacións

CaracterísticaDetalle
Número de modeloSDC15
Modo de operaciónManual
Clasificación actual (ventilador)1.5 Amps
Wattage (luz)300 Watts (Incandescent Max)
Vol. Operativotage120 voltios
Frecuencia60 Hz
Tipo de circuíto3 vías
Tipo de contactoNormalmente aberto
Tipo de conectorParafuso
Tipo de actuadorPush Button (Slider)
Método de controlTouch (Slider)
CorBranco
Dimensións (L x W x H)4.25 x 1.75 x 2 polgadas
Peso do elemento4.8 onzas
Clasificación de protección internacionalIP44
FabricanteIndustrias Cooper

Información da garantía

Warranty information for the Cooper Lighting SDC15-W Fan/Light Control is typically provided with your purchase or can be obtained directly from the manufacturer. Please retain your proof of purchase for warranty claims.

Atención ao cliente

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact Cooper Lighting customer support. Refer to the packaging or the official Cooper Lighting websitio para obter a información de contacto máis actualizada.

Documentos relacionados - SDC15

Preview Cooper Lighting Occupancy and Vacancy Sensors Catalog
Product catalog from Cooper Lighting featuring a range of ultrasonic, PIR, and dual technology occupancy and vacancy sensors for various applications, including wall, ceiling, and fixture mount. Details include catalog numbers, descriptions, UPC codes, weights, quantities, and country of origin.
Preview LENSGO 15A COB LED Light: Instruction Manual & Specifications
Comprehensive instruction manual for the LENSGO 15A COB LED light. Learn about setup, operation, features, specifications, and safety precautions for this portable photography lighting solution.
Preview Documento técnico de Eaton xDetect: Migración dos paneis de incendios CF3000 a xDetect
A white paper from Eaton exploring the migration path from the discontinued CF3000 fire control panel range to the new xDetect system, focusing on safety, compliance, cost efficiency, and business continuity. It details the challenges of discontinuation and the benefits of upgrading.
Preview GL LED US Lighting OMP-300W-12V LED Driver - 300W, 12V DC, IP68
Detailed specifications for the GL LED US Lighting OMP-300W-12V LED Driver. Features 300W max output, 12V DC, 90-277VAC input, IP68 rating, 5-year warranty, and constant voltage operation for various lighting applications.
Preview PROLIGHTS EclExpo Flood300VW User Manual: 300W Asymmetric LED Floodlight
Comprehensive user manual for the PROLIGHTS EclExpo Flood300VW, a 300W asymmetric LED floodlight with variable white CCT (2,700K - 6,500K). Covers safety, installation, DMX control, RDM functions, maintenance, and troubleshooting.
Preview Manual de instalación e funcionamento do transformador de iluminación de xardíns Harbor Breeze de 300 W
Guía completa para instalar e operar o transformador de iluminación de xardíns Harbor Breeze de 300 W, que inclúe instrucións de seguridade, pasos de montaxe, guía de cableado, modos de funcionamento, resolución de problemas e información sobre a garantía.