deleyCON MK899

Manual do usuario do detector de movemento infravermello deleyCON MK899

Modelo: MK899

1. Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of your deleyCON MK899 Infrared Motion Detector. This device is designed for indoor use to automatically control lighting based on detected movement and ambient light levels. Please read this manual thoroughly before installation and use to ensure proper function and safety.

2. Instrucións de seguridade

  • Installation must be performed by a qualified electrician in accordance with local electrical codes and regulations.
  • Disconnect power at the circuit breaker before installing or servicing the device.
  • Do not install in areas with high humidity or direct water exposure (IP20 rating: suitable for indoor, dry environments only).
  • Asegurar a subministración voltage matches the specifications of the motion detector.
  • Do not open the device housing or attempt to modify the internal components.

3. Contido do paquete

Verifica que todos os compoñentes estean presentes no paquete:

  • 1x deleyCON Infrared Motion Detector (MK899)
  • 1 x Manual de usuario
  • 2x Screws with dowels for mounting

4. Produto rematadoview

The deleyCON MK899 motion detector features a compact design for ceiling surface mounting. It includes adjustable settings for light duration and ambient light sensitivity.

Close-up of deleyCON MK899 motion detector showing sensor, TIME and LUX adjustment dials, and control LED.

Imaxe 1: Primeiro plano view of the motion detector's sensor, adjustment dials, and control LED. The dials are labeled 'TIME' for light duration and 'LUX' for light sensitivity.

  1. Sensor: Detects infrared radiation from moving objects.
  2. TIME Adjustment Dial: Controls the duration the light remains on after motion detection.
  3. LUX Adjustment Dial: Sets the ambient light threshold for activation.
  4. Control Lamp (LED): Indicates motion detection and operational status.

5. Especificacións

CaracterísticaEspecificación
Número de modeloMK899
MarcadeleyCON
Dimensións do produto (L x W x H)11.5 x 11.5 x 5.8 cm
Peso161 gramos
CorBranco
Tipo de potenciaAC (corrente alterna)
Tipo de montaxeMontaxe superficial (teito)
Ángulo de detección360°
Rango máximo de detección6 metros
Clase de protecciónIP20 (uso en interiores)
Adjustable Light Duration (TIME)10 segundos a 7 minutos
Adjustable Ambient Brightness (LUX)Si
Dispositivos compatiblesLights (Lamps, LEDs)
Rango de temperatura de funcionamento60 Degrees Celsius (Note: This value seems unusually high for an operating range. Please refer to product packaging for exact operating temperature limits.)

6. Configuración e instalación

The deleyCON MK899 is designed for surface mounting on ceilings. Ensure power is disconnected before proceeding.

6.1 Montaxe do dispositivo

  1. Separate the mounting plate from the main unit by twisting or unlatching as indicated by the device design.
  2. Position the mounting plate on the desired ceiling location. Mark the drilling points through the holes on the plate.
  3. Drill holes at the marked positions and insert the provided dowels.
  4. Secure the mounting plate to the ceiling using the provided screws.
Traseira view of the deleyCON MK899 motion detector showing the detachable mounting plate and wiring terminals.

Imaxe 2: Traseira view of the motion detector, illustrating the detachable mounting plate and the internal wiring terminals.

6.2 Diagrama de cableado

Follow the wiring diagram carefully. Incorrect wiring can damage the device or connected lights.

Wiring diagram for the deleyCON MK899 motion detector, showing connections for Live (L), Neutral (N), and Load (A) to a light bulb.

Imaxe 3: Wiring schematic for the motion detector. Connect the Live (L) and Neutral (N) input wires, and the Load (A) output wire to the light fixture. The diagram shows L (Phase/Hot), N (Neutral/Ground), and A (Consumer/Lamp).

  • Connect the Live (L) wire from your power supply to the 'IN~ L' terminal.
  • Connect the Neutral (N) wire from your power supply to the 'IN~ N' terminal.
  • Connect the Live wire of your light fixture (Load) to the 'OUT~ LOAD' terminal.
  • Connect the Neutral wire of your light fixture to the 'IN~ N' terminal (shared with incoming neutral).

After wiring, attach the main unit to the mounting plate, ensuring it is securely fastened.

7. Instrucións de funcionamento

Once installed and powered, the motion detector will enter a warm-up period (typically 30-60 seconds) during which it may activate randomly. After this, it will be ready for operation and adjustment.

7.1 Adjusting Light Duration (TIME)

The 'TIME' dial controls how long the connected light remains on after motion is detected and the detection zone is clear. Rotate the dial to set the desired duration:

  • '-' (Minimum): Aproximadamente 10 segundos.
  • '+' (Maximum): Aproximadamente 7 minutos.

7.2 Adjusting Ambient Light Sensitivity (LUX)

The 'LUX' dial determines the ambient light level at which the motion detector will activate. This prevents the light from turning on during daylight hours when not needed.

  • '☼' (Sun Symbol - Maximum): The detector will activate regardless of ambient light (day and night).
  • '☽' (Moon Symbol - Minimum): The detector will only activate in very low light conditions (dusk/night).

Adjust the dial to your preferred setting. For testing, set it to the 'Sun' symbol to ensure functionality during daylight.

7.3 Área de detección

The deleyCON MK899 offers a 360° detection angle with a maximum range of 6 meters, ideal for comprehensive coverage in indoor spaces.

Illustration showing the 360-degree detection area and 6-meter range of the motion detector.

Imaxe 4: Visual representation of the motion detector's 360° detection angle and maximum 6-meter range, suitable for indoor environments.

8. Mantemento

The deleyCON MK899 motion detector requires minimal maintenance.

  • Limpeza: Limpe o dispositivo cun pano suave e seco. Non empregue produtos de limpeza abrasivos nin disolventes.
  • Inspección: Periodically check for any visible damage or loose connections.
  • The device contains no user-serviceable parts. Do not attempt to disassemble it.

9 Solución de problemas

If you encounter issues with your motion detector, refer to the following common problems and solutions:

ProblemaCausa posibleSolución
A luz non se acende cando se detecta movemento.
  • Incorrect LUX setting (too high).
  • Non hai enerxía para o dispositivo.
  • Cableado defectuoso.
  • Motion outside detection range.
  • Adjust LUX dial towards the 'Moon' symbol.
  • Comprobe o disxuntor e as conexións de alimentación.
  • Verify wiring according to the diagram.
  • Ensure motion occurs within 6m range and 360° angle.
A luz permanece acesa continuamente.
  • Movemento constante na área de detección.
  • Incorrect TIME setting (too long).
  • Mal funcionamento do dispositivo.
  • Ensure no continuous movement or heat sources (e.g., heating vents) are within the detection zone.
  • Adjust TIME dial towards the '-' symbol.
  • If problem persists, disconnect power and consult a professional.
Light turns on too frequently or randomly.
  • LUX setting too sensitive.
  • Small animals or objects causing detection.
  • Drafts or temperature fluctuations.
  • Adjust LUX dial towards the 'Sun' symbol.
  • Relocate the detector or adjust its position to avoid unwanted triggers.
  • Ensure stable environmental conditions.

10. Garantía e soporte

For warranty information and technical support, please refer to the documentation provided with your purchase or visit the official deleyCON websitio. Garda o comprobante de compra para calquera reclamación de garantía.

Documentos relacionados - MK899

Preview deleyCON HDMI Wanddose 4K Benutzerhandbuch
Umfassendes Benutzerhandbuch für die deleyCON HDMI Wanddose 4K. Enthält Installationsanleitungen, technische Daten, Sicherheitshinweise und Informationen zur Produktkonformität für Modelle wie MK3164.
Preview deleyCON Mini Infrarød Bevægelsesdetektor Quickstart Guide
Denne quickstart guide giver en oversigt over deleyCON's mini infrarøde bevægelsesdetektor, inklusive installationsvejledning, sikkerhedsinstruktioner og tekniske specifikationer. Lær hvordan du korrekt installerer og bruger din bevægelsesdetektor til optimal ydeevne.
Preview deleyCON Audio Cinch Kabel: Benutzerhandbuch und technische Informationen
Umfassendes Benutzerhandbuch für deleyCON Audio Cinch Kabel (RCA-Kabel). Erfahren Sie mehr über Produktdetails, technische Spezifikationen, Sicherheitshinweise und Konformitätserklärungen für Modelle wie MK4085. Enthält Informationen zur Installation, Verwendung und Entsorgung.