The BWT Aquameter LF (Low Flow) is designed to precisely monitor the volume of water that has passed through your water filter system. This device helps ensure timely filter replacement, maintaining optimal water quality for applications such as espresso machines. It features an LCD display for real-time capacity tracking and is compatible with various BWT water filters, including Bestmax and Besttaste series.

Produto rematadoview

BWT Aquameter LF control unit and flow sensor

Figura 1: BWT Aquameter LF control unit with LCD display and separate flow sensor, connected by a cable. This image shows the main components of the Aquameter LF system.

BWT Aquameter LF product packaging

Figura 2: The packaging for the BWT Aquameter LF, indicating its 3/8" connection and NSF certification. The packaging also displays the product number 812136 and GTIN 04250266700169.

Configuración e instalación

  1. Desempaquetar compoñentes: Carefully remove the BWT Aquameter LF control unit, flow sensor, and connecting cable from the packaging.
  2. Identify Flow Direction: The flow sensor has an arrow indicating the direction of water flow. Ensure this aligns with your water line.
  3. Connect Flow Sensor: Install the 3/8" flow sensor into the water line before your BWT water filter. Use appropriate plumbing fittings to ensure a secure, leak-free connection.
    BWT Aquameter LF installed with water filter

    Figura 3: The BWT Aquameter LF control unit mounted on a wall, connected to a BWT Bestmax water filter installed under a sink. This illustrates a typical installation setup.

  4. Conectar a Unidade de Control: Plug the cable from the flow sensor into the designated port on the BWT Aquameter LF control unit.
  5. Unidade de control de montaxe: Mount the control unit in a convenient location using the provided mounting hardware. Ensure the display is easily visible.
    Close-up of BWT Aquameter LF control unit installed

    Figura 4: Un primeiro plano view of the BWT Aquameter LF control unit mounted, showing the LCD display, "PROG." and "RESET" buttons, and the CE mark. The cable connecting to the flow sensor is visible.

  6. Programación inicial:
    • Press and hold the "PROG." button to enter programming mode.
    • Use the "PROG." button to cycle through settings (e.g., total filter capacity in liters).
    • Use the "RESET" button to adjust the values for each setting.
    • Confirm settings by pressing "PROG." again or waiting for the unit to exit programming mode automatically.
    • Set the filter capacity according to your specific BWT filter model and local water hardness.

Instrucións de funcionamento

Mantemento

Resolución de problemas

ProblemaCausa posibleSolución
A pantalla está en branco ou escura.Baterías baixas ou esgotadas.Contact BWT support for battery replacement.
Capacity not decreasing.Flow sensor incorrectly installed or faulty. No water flow detected.Check flow sensor installation, ensuring correct flow direction. Verify water flow through the system.
Incorrect capacity reading after filter change.Meter not reset after filter replacement.Press and hold the "RESET" button for 3 seconds to reset the meter.
Water leakage at connections.Loose fittings or improper sealing.Ensure all plumbing connections are tight and properly sealed with appropriate thread sealant or tape.

Especificacións

Información da garantía

For detailed warranty information regarding your BWT Aquameter LF, please refer to the warranty card included with your product or visit the official BWT websitio. Os termos e condicións da garantía poden variar segundo a rexión.

Apoio

If you require further assistance, technical support, or have questions about your BWT Aquameter LF, please contact BWT customer service or visit the official BWT store online.

Visit the BWT Store on Amazon

Documentos relacionados - 812195

Preview Manual de instalación e funcionamento do sistema de filtro de auga BWT R1 RSF e HWS
Manual completo de instalación, posta en servizo, funcionamento e mantemento dos sistemas de filtro de auga BWT R1 RSF e BWT R1 HWS. Inclúe especificacións técnicas, resolución de problemas e información de seguridade.
Preview Manual de instalación e funcionamento do filtro de punto de entrada BWT Multi C
Este manual proporciona instrucións de instalación e funcionamento para o filtro de punto de entrada BWT Multi C, incluídos os tipos 1000, 2000 e 3000. Abarca o alcance da subministración, o uso previsto, a función, os fallos de alimentación eléctrica, as condicións de instalación, os axustes de fábrica, os procedementos de posta en marcha, o mantemento, a garantía, as responsabilidades do operador e as especificacións técnicas.
Preview Manual do usuario da aspiradora recargable para piscinas e spas BWT FISPA VAC | Funcionamento, mantemento e resolución de problemas
Manual de usuario completo para o aspirador recargable para piscinas e spas BWT FISPA VAC. Inclúe información sobre a configuración, o funcionamento, o mantemento, os avisos de seguridade, a resolución de problemas e a garantía.
Preview BWT Multipur M Backwash Filter Installation and Operating Manual
This manual provides comprehensive instructions for the installation, operation, maintenance, and troubleshooting of the BWT Multipur M backwash filter, covering models DN 65 through DN 150.
Preview Instrucións de montaxe e funcionamento de BWT pro-soft 11
Guía completa para o descalcificador de auga BWT pro-soft 11, que abrangue a instalación, o funcionamento, o mantemento e a resolución de problemas. Aprende a descalcificar eficazmente o teu subministro de auga doméstico.
Preview BWT In-Line Drinking Water Filter Kit: Installation and Operating Guide
Comprehensive installation, operation, and troubleshooting guide for the BWT In-Line Drinking Water Filter Kit, including specifications, parts, precautions, and maintenance.