Okin SP2-B

OEM Okin Power Supply Transformer with Power Cord

Modelo: SP2-B

Produto rematadoview

The Okin SP2-B AC/DC Switching Power Supply is designed to provide reliable power for 24V DC motors commonly found in lift chairs. This unit is compatible with various lift chair brands and motor types, including BetaDrive and DeltaDrive Okin Lift Chair Motors. It also features a battery backup compartment for 9-volt batteries (not included), ensuring continued operation during power outages.

Okin SP2-B Power Supply, AC Cord, and DC Cord

Figure 1: The Okin SP2-B power supply unit, accompanied by its detachable AC power cord and DC output cord.

Características clave

Especificacións

Número de modeloSP2-B (Version No: 3.00.209.014.00)
Vol. De entradatageCA 100-240V, 50 / 60Hz, 2.0A
Vol. De saídatageDC 29V, 2.0A
CompatibilidadeOkin, Limoss, Hmleaf, Tranquil Ease Lift Chair and Power Recline DeltaDrive and BetaDrive Motors
Conexión de motor2-pin (one flat, one round)
Copia de seguridade da bateríaRequires 9V batteries (not included)
Números de peza comúnsW52RA73-290018, KDDY001, KDDY008, ZB A290020-B
Back label of Okin SP2-B Power Supply showing specifications

Figura 2: Traseira view of the power supply unit, displaying the model number, input/output specifications, and safety certifications.

Configuración

  1. Desempaquetar compoñentes: Carefully remove the power supply unit, AC power cord, and DC output cord from the packaging.
  2. Connect AC Power Cord: Insert the included AC power cord into the designated AC input port on the power supply unit. Ensure a firm connection.
  3. Close-up of AC input port on Okin SP2-B Power Supply

    Imaxe 3: Primeiro plano view of the AC input port on the power supply, where the detachable AC power cord connects.

  4. Connect DC Output Cord: Plug the DC output cord into the corresponding DC output port on the power supply unit. This cord will connect to your lift chair motor.
  5. Close-up of DC output port on Okin SP2-B Power Supply

    Imaxe 4: Primeiro plano view of the DC output port on the power supply, which connects to the lift chair motor.

  6. Install Battery Backup (Optional): For battery backup functionality, open the battery compartment on the side of the power supply unit. Insert two 9-volt batteries, observing the correct polarity (+/-). Close the compartment securely.
  7. Okin SP2-B Power Supply with battery compartment open

    Figure 5: The power supply unit with its battery backup compartment open, ready for 9-volt battery installation.

  8. Connect to Lift Chair: Connect the 2-pin DC output cord from the power supply to the corresponding input on your lift chair's motor.
  9. Enchufe na toma de parede: Finally, plug the AC power cord into a standard 120V wall outlet.

Instrucións de funcionamento

Once the power supply is correctly connected to the lift chair and plugged into a wall outlet, the lift chair should be ready for operation. Use the chair's standard remote control or integrated buttons to control its movement. The power supply will convert the AC household current to the necessary DC voltage para o motor.

If 9-volt batteries are installed in the battery backup compartment, the lift chair will retain limited functionality during a power outage, typically allowing for one or two full cycles (raise/lower) depending on battery charge and motor load. This feature is intended for emergency use to return the chair to a seated position.

Mantemento

Resolución de problemas

If your lift chair is not operating correctly, review os seguintes problemas e solucións comúns:

Garantía e Soporte

This Okin power supply is manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided at the time of purchase or contact the retailer. In many cases, replacement parts like this power supply are covered by a limited manufacturer's warranty against defects in materials and workmanship.

For technical support or inquiries regarding replacement parts, please contact the manufacturer, Okin, or the authorized seller from whom you purchased the product. You may also visit the Tenda Okin en Amazon para obter información e recursos adicionais sobre o produto.

Documentos relacionados - SP2-B

Preview Guía de resolución de problemas de Okin Systems: Reparación e mantemento da cadeira elevadora
Guía completa de resolución de problemas para os sistemas Okin empregados en cadeiras elevadoras. Aprende a diagnosticar e solucionar problemas comúns con controis manuais, transformadores, motores e porcas do eixo. Inclúe consellos de instalación.
Preview Manual de funcionamento do sistema de control remoto OKIN Refined Electric Technology
Este manual proporciona instrucións de funcionamento detalladas para o sistema de control remoto OKIN Refined Electric Technology, que abarcan descricións dos botóns, axustes de posición especiais e procedementos de emparellamento sen fíos.
Preview Guía de substitución do control remoto OKIN HSW306 de 5 a 7 pines
Instrucións paso a paso para substituír un control remoto para cadeira reclinable OKIN HSW306 de 5 pines por un modelo de 7 pines, incluíndo a derivación do cableado, os pasos de instalación e os accesorios recomendados.
Preview Guía de instalación e funcionamento de OKIN POWER PACK 1800
Instrucións detalladas de instalación e funcionamento para o OKIN POWER PACK 1800, unha fonte de alimentación independente da rede para aplicacións electromecánicas axustables. Inclúe datos técnicos, avisos de seguridade e resolución de problemas.
Preview Manual do usuario do sistema de control remoto OKIN RF.31.24.01
Manual de usuario completo para o sistema de control remoto de 22 teclas OKIN RF.31.24.01, que detalla as funcións dos botóns, os procedementos de axuste da posición e os compoñentes do sistema para camas axustables.
Preview OKIN RF401B System Instruction Manual
This document provides system instructions for the OKIN RF401B remote control, detailing the function of each button and its operation.