1. Introdución
This manual provides essential information for the proper installation, operation, and maintenance of the AKO D-14323 230V Universal Digital Temperature Controller. Designed for industrial and commercial refrigeration applications, this controller offers precise temperature management and adjustable defrost cycles. Please read this manual thoroughly before installation and use to ensure safe and efficient operation.
2. Información de seguridade
Observe sempre as seguintes precaucións de seguridade para evitar lesións persoais ou danos no dispositivo:
- A instalación e o mantemento só deben ser realizados por persoal cualificado.
- Disconnect power to the unit before performing any wiring or maintenance.
- Asegúrese de que a fonte de alimentación voltage matches the controller's specifications (230V).
- Protect the device from water, moisture, and extreme temperatures.
- Do not open the controller housing unless specifically instructed.
3. Produto rematadoview
The AKO D-14323 is a versatile digital temperature controller equipped with a clear digital display and intuitive controls. It is suitable for a wide range of refrigeration and freezer units.
Características principais:
- Digital thermostat for industrial and commercial freezers.
- Temperature range from -50.0 °C to +99.9 °C (-58°F to +210.2°F).
- Three relays for compressor, fan, and auxiliary functions.
- Two temperature sensors included.
- Panel mounting design.
- Programmable defrost cycles.
- Fahrenheit and Celsius readings.
- Programmable digital inputs for door switch, alarm, remote defrost, energy saving, or continuous cycle.
Controller Front Panel:

Imaxe 3.1: Fronte view of the AKO D-14323 controller, showing the digital display and control buttons. The display shows temperature readings, and buttons include ESC, SET, Power, and up/down arrows (often used for defrost and parameter adjustment).
The front panel features a digital display for temperature readings and status indicators. Control buttons allow for setting parameters, initiating defrost cycles, and navigating menus.
4. Instalación e configuración
Proper installation is crucial for the controller's performance and longevity.
4.1 Montaxe en panel
The AKO D-14323 is designed for panel mounting. Ensure adequate space for ventilation and access to wiring terminals.
4.2 Conexións eléctricas
Refer to the wiring diagram on the back of the unit for correct electrical connections. All wiring must comply with local electrical codes.

Imaxe 4.1: De volta view of the AKO D-14323 controller, displaying the wiring diagram and product specifications. This diagram illustrates connections for power (230V), sensors (S1, S2), compressor (COOL), fan, and auxiliary outputs, along with digital inputs (D1, D2).
Wiring Key Points:
- Fonte de alimentación: Connect 230V AC to the designated terminals.
- Sensores: Connect the two temperature sensors (S1, S2) to their respective terminals.
- Saídas de relé: Connect the compressor, fan, and auxiliary loads to their corresponding relay terminals. The diagram specifies maximum current ratings for each output (e.g., COOL: 12(9)A 250V~, FAN: 5(4)A 250V~, AUX: 8(4)A 250V~).
- Entradas dixitais: Utilize terminals for programmable digital inputs such as door switches or external alarms.
4.3 Encendido inicial
After wiring, apply power to the controller. The display should illuminate, showing the current temperature or an initial setup prompt.
5. Instrucións de funcionamento
The AKO D-14323 offers various programmable parameters to suit different refrigeration needs.
5.1 Funcionamento básico
- Visualización da temperatura: The main display shows the current temperature measured by the primary sensor.
- Botón SET: Preme para view or modify the setpoint temperature. Hold to enter parameter programming mode.
- Botón ESC: Used to exit menus or cancel changes.
- Frechas cara arriba/abaixo: Used to adjust values in programming mode or manually initiate defrost (if configured).
- Botón de encendido: Turns the unit on/off or acts as a reset in some configurations.
5.2 Setting the Temperature Setpoint
- Preme o SET button briefly. The current setpoint will flash.
- Usa o Up or Abaixo botóns de frecha para axustar a temperatura desexada.
- Preme SET again to confirm and save the new setpoint, or ESC para saír sen gardar.
5.3 Advanced Parameter Programming
To access advanced parameters (e.g., defrost cycles, differential, auxiliary relay functions), hold the SET button for several seconds until the first parameter code appears. Navigate using the arrow buttons and press SET to enter/confirm values. Refer to the detailed programming guide (usually provided separately or available from AKO) for a complete list of parameters and their functions.
5.4 Defrost Cycle Management
The controller supports various defrost methods, including controlling the compressor, resistance heaters, or fans. Defrost parameters can be adjusted to optimize performance based on the application. An optional probe allows defrosting by temperature.
6. Mantemento
Regular maintenance ensures optimal performance and extends the lifespan of your temperature controller.
- Limpeza: Limpe periodicamente o panel frontal cun pano suave eamp pano. Non use produtos de limpeza ou disolventes abrasivos.
- Inspeccións: Regularly check wiring connections for tightness and signs of wear or corrosion.
- Comprobación do sensor: Ensure temperature sensors are securely in place and free from damage.
For any internal maintenance or repairs, contact a qualified technician.
7 Solución de problemas
If you encounter issues with your AKO D-14323 controller, refer to the following common problems and solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| A pantalla está en branco | Sen subministración de enerxía; cableado incorrecto | Check power connections and ensure 230V supply. Verify wiring according to the diagram. |
| Lectura incorrecta da temperatura | Faulty sensor; sensor not properly connected or placed | Check sensor connections. Replace sensor if damaged. Ensure sensor is correctly positioned in the controlled environment. |
| Compressor/Fan not operating | Setpoint issue; relay fault; wiring error; parameter misconfiguration | Verify setpoint and differential settings. Check wiring to the compressor/fan. Review advanced parameters for correct configuration. |
| Defrost not initiating | Defrost parameters incorrect; manual defrost not triggered | Check defrost cycle settings (interval, duration, temperature). Attempt manual defrost if configured. |
If the problem persists after attempting these solutions, contact AKO technical support or a qualified service technician.
8. Especificacións
Detailed technical specifications for the AKO D-14323 controller:
- Modelo: AKO D-14323
- Voltage: 230 voltios
- Rango de temperatura: -50.0 °C to +99.9 °C (-58°F to +210.2°F)
- Relés: 3 (Compressor, Fan, Auxiliary)
- Sensores: 2 temperature sensors included
- Montaxe: Montaxe en panel
- Material: Plástico
- Peso do artigo: 0.01 onzas (aproximadamente)
- Estilo de visualización: Dixital
- Características especiais: Programable
- Uso: Comercial / Residencial
- Certificacións: ETL, CE, IP65, GAMA
- Fabricante: AKOCONTROL
9. Garantía e soporte
For warranty information and technical support, please contact AKO directly or refer to their official websitio. Conserve o recibo de compra para reclamacións de garantía.
Fabricante: AKOCONTROL
Websitio: www.ako.com