Wilo TWU4-0409-C-EM

Wilo SUB TWU 4 Submersible Pump Instruction Manual

Model: TWU4-0409-C-EM

1. Introdución

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Wilo SUB TWU 4 submersible pump, model TWU4-0409-C-EM. Please read these instructions carefully before installation and use to ensure proper function and to prevent damage or injury. Keep this manual for future reference.

2. Información de seguridade

Avisos xerais de seguridade:

  • Always disconnect the power supply before performing any work on the pump or its electrical components.
  • Installation and maintenance should only be performed by qualified personnel in accordance with local regulations and standards.
  • Ensure the pump is correctly grounded to prevent electrical shock.
  • Do not operate the pump dry. Running without water will cause severe damage.
  • Protexa a bomba de temperaturas de conxelación.
  • Use only genuine Wilo spare parts for repairs.

3. Configuración e instalación

3.1 Desembalaxe

Carefully remove the pump from its packaging. Inspect the pump for any visible damage that may have occurred during transit. Report any damage to your supplier immediately.

Wilo SUB TWU 4 Submersible Pump

Figure 1: Wilo SUB TWU 4 Submersible Pump. This image shows the pump unit, highlighting its compact design suitable for well installation.

3.2 Pump Selection Guide (TWU Series)

The following table provides a guide for selecting the appropriate TWU series pump based on required head (H) and flow rate (Q). This helps ensure optimal performance for your specific application.

Table 1: Wilo TWU Pump Selection Guide
H/Q<2.5 m³/h2.5 a 3 m³/h3 a 3.5 m³/h3.5 a 4 m³/h4 a 4.5 m³/h4.5 a 5 m³/h5 a 5.5 m³/h
110 mTWU 4-0418-C
100 mTWU 4-0418-CTWU 4-0418-C
90 mTWU 4-0418-CTWU 4-0418-CTWU 4-0418-C
80 mTWU 4-0414-CTWU 4-0418-CTWU 4-0418-CTWU 4-0418-C
70 mTWU 4-0414-CTWU 4-0414-CTWU 4-0414-CTWU 4-0418-CTWU 4-0418-C
60 mTWU 4-0414-CTWU 4-0414-CTWU 4-0414-CTWU 4-0414-CTWU 4-0418-C
50 mTWU 4-0409-CTWU 4-0414-CTWU 4-0414-CTWU 4-0414-CTWU 4-0414-CTWU 4-0418-CTWU 4-0418-C
40 mTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0414-CTWU 4-0414-CTWU 4-0418-C
30 mTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0414-CTWU 4-0414-C
20 mTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0409-CTWU 4-0409-C

Note: H represents the total head in meters, and Q represents the flow rate in cubic meters per hour. The colors in the table correspond to different pump models (e.g., light blue for TWU 4-0418-C, orange for TWU 4-0414-C, grey for TWU 4-0409-C).

3.3 Conexión eléctrica

Connect the pump to a suitable power supply according to the pump's specifications and local electrical codes. Ensure the voltage and frequency match the pump's requirements. A residual current device (RCD) with a tripping current of no more than 30 mA is recommended for additional safety.

3.4 Conexión de tubos

Connect the discharge pipe to the pump outlet. Ensure all connections are watertight and free from leaks. Use appropriate sealing materials. The pipe diameter should be sufficient to minimize pressure loss.

4. Instrucións de funcionamento

4.1 Posta en marcha inicial

Before starting the pump, ensure it is fully submerged in water. Connect the power supply. The pump should start automatically if equipped with a float switch, or manually if controlled by an external switch. Monitor the pump for unusual noises or vibrations during the first few minutes of operation.

4.2 Funcionamento continuo

The Wilo SUB TWU 4 is designed for continuous operation within its specified performance range. Avoid operating the pump outside these limits to prevent premature wear or damage. Regularly check the water level to ensure the pump remains submerged.

4.3 Apagado

To shut down the pump, disconnect the power supply. If the pump is to be out of service for an extended period, follow the maintenance and storage guidelines.

5. Mantemento

Regular maintenance ensures the longevity and reliable operation of your pump.

5.1 Comprobacións periódicas

  • Inspeccione o cable de alimentación para detectar calquera sinal de danos ou desgaste.
  • Check the pump's intake for blockages from debris.
  • Ensure all pipe connections remain secure and leak-free.

5.2 Limpeza

If the pump's performance decreases, it may be due to blockages. Disconnect power, remove the pump, and clean the intake screen and impeller area. Use clean water and a soft brush. Do not use harsh chemicals.

5.3 Invernización

If the pump is installed in an area subject to freezing temperatures and will not be used, it must be removed from the water and stored in a frost-free environment. Drain all water from the pump and pipes to prevent damage from ice expansion.

6 Solución de problemas

Antes de contactar co servizo de atención ao cliente, volva aview os seguintes problemas comúns e as súas posibles solucións:

ProblemaCausa posibleSolución
A bomba non arrancaNo power supply; tripped circuit breaker; faulty float switch; motor fault.Check power connection; reset breaker; inspect float switch; contact service.
Pump runs but no water deliveryAir in system; clogged intake/impeller; low water level; discharge pipe blockage.Bleed air; clean intake/impeller; ensure pump is submerged; check discharge pipe.
Caudal reducidoPartial blockage; worn impeller; excessive head loss in piping.Clean pump; inspect impeller; check pipe sizing and condition.
Ruído ou vibración excesivosDebris in pump; worn bearings; improper installation.Clean pump; contact service for bearing replacement; verify stable installation.

7. Especificacións

Key technical specifications for the Wilo SUB TWU 4 submersible pump, model TWU4-0409-C-EM:

  • Marca: Wilo
  • Número de modelo: TWU4-0409-C-EM (also referred to as 'sub twu 4')
  • Estilo: Sumerxible
  • Potencia: 0.75 kW
  • GTIN: 04044966515679
  • Dimensións do paquete: 22.8 x 18.8 x 13 cm
  • Peso do artigo: 1.21 kg
  • Fabricante: Wilo
  • Primeira data dispoñible: 16 de maio de 2017

Note: For detailed performance curves and specific electrical data, refer to the official Wilo product documentation or contact Wilo technical support.

8. Garantía e soporte

For warranty information, please refer to the warranty card included with your product or visit the official Wilo website. Technical support and spare parts can be obtained through authorized Wilo dealers or directly from Wilo customer service. Please have your model number (TWU4-0409-C-EM) and purchase date available when contacting support.

Documentos relacionados - TWU4-0409-C-EM

Preview Wilo-Sub TWU 3 & TWU 3-...-P&P: Installation and Operating Instructions
Official installation and operating manual for Wilo-Sub TWU 3 and TWU 3-...-P&P submersible motor pumps. Learn about safe setup, operation, and maintenance for water supply and irrigation.
Preview Каталог насосов Wilo для бытового применения: отопление, водоснабжение, водоотведение
Обзор высокоэффективных циркуляционных насосов Wilo для систем отопления, водоснаботи ведодения. Информация для продавцов e монтажников.
Preview Wilo TWI & TWU 4" Submersible Well Pumps: Installation and Operating Instructions
Comprehensive installation and operating instructions for Wilo TWI & TWU 4-inch submersible well pumps. Covers general information, safety precautions, product description, assembly, installation, electrical connections, operation, maintenance, and troubleshooting.
Preview Wilo-EMU FA + FK 17.1, FK 202, FK 34, FK 42 Installation and Operating Instructions
This document provides comprehensive installation and operating instructions for the Wilo-EMU FA and FK series submersible sewage pumps, including models FK 17.1, FK 202, FK 34, and FK 42. It covers essential safety guidelines, product details, installation procedures, commissioning steps, maintenance, and troubleshooting for reliable operation.
Preview Bombas de motor mergullábeis Wilo: Instrucións de instalación e funcionamento
Instrucións detalladas de instalación e funcionamento para as bombas de motor mergullables Wilo, incluíndo modelos como Wilo-EMU, Wilo-Sub TWI e Wilo-Actun ZETOS-K. Abarca a seguridade, a descrición do produto, o transporte, a instalación, a posta en marcha, o mantemento, a parada e a resolución de problemas.
Preview Instrucións de instalación e funcionamento de Wilo-Plavis ...-C
Wilo-Plavis ...-C condensate lifting station for boilers, air conditioning, cooling, and dehumidification systems. Provides installation, operation, and maintenance instructions.