Yaskawa CIMR-VU2A0006FAA

Yaskawa V1000 AC Drive Instruction Manual

Model: CIMR-VU2A0006FAA

1. Produto rematadoview

The Yaskawa V1000 is a compact, high-performance AC microdrive designed for a wide range of industrial applications. It offers precise motor control, energy efficiency, and ease of use. This manual provides essential information for the safe and effective operation of your V1000 AC Drive.

Yaskawa V1000 AC Drive, front view

Figura 1: Fronte view of the Yaskawa V1000 AC Drive (Model CIMR-VU2A0006FAA). This image shows the drive's compact design, control panel with display and buttons, and ventilation fins on the side.

2. Información de seguridade

WARNING: Risk of electric shock. Ensure power is disconnected before installation or maintenance.

Read this manual thoroughly before installing, operating, or performing maintenance on the V1000 AC Drive. Failure to follow these instructions may result in serious injury or equipment damage.

2.1 Precaucións xerais de seguridade

2.2 Consideracións ambientais

3. Configuración

Proper installation and wiring are crucial for the safe and reliable operation of the V1000 AC Drive.

3.1 Montaxe

Mount the drive vertically on a flat, stable surface. Ensure adequate clearance for ventilation around the drive (minimum 50mm above and below, 25mm on sides).

3.2 Cableado

Refer to the wiring diagram provided in the full product manual for detailed connections. Key connections include:

  1. Power Input (R/L1, S/L2, T/L3): Connect the 3-phase 200-240V AC power supply.
  2. Saída do motor (U, V, W): Connect to the motor terminals.
  3. Terra (PE): Connect to a reliable earth ground.
  4. Terminais de control: For external control signals (e.g., run/stop, speed reference, fault output).

Always use appropriate wire gauges and circuit protection devices as specified in local electrical codes and the drive's technical specifications.

4. Operating the V1000 AC Drive

The V1000 drive can be operated via its integrated control panel or external control signals.

4.1 Panel de control rematadoview

O panel de control inclúe unha pantalla dixital e varios botóns:

4.2 Pasos básicos de funcionamento

  1. Encendido: Conecte a alimentación á unidade. A pantalla iluminarase.
  2. Configuración de parámetros: Configure essential parameters such as motor data (voltage, current, frequency), acceleration/deceleration times, and control mode (V/f, vector control). Refer to the parameter list in the detailed manual.
  3. Start Command: Preme o CORRER button on the control panel or activate the external run command.
  4. Axuste de velocidade: Adjust the motor speed using the UP/DOWN arrows (if in local control mode) or via external speed reference.
  5. Stop Command: Preme o PARA button or deactivate the external stop command.

5. Mantemento

Regular maintenance ensures the longevity and optimal performance of your V1000 AC Drive.

5.1 Comprobacións de rutina

5.2 Limpeza

Use a soft, dry cloth to clean the exterior of the drive. For internal cleaning (only by qualified personnel with power disconnected), use compressed air to remove dust from heat sinks and circuit boards.

Always disconnect power and wait for the charge lamp to extinguish before performing any maintenance.

6 Solución de problemas

This section provides common issues and their potential solutions. For complex problems, consult a qualified technician or Yaskawa support.

ProblemaCausa posibleSolución
Drive does not power on.No input power; Blown fuse.Check power supply; Replace fuse (after identifying cause).
O motor non funciona.No run command; Incorrect wiring; Motor fault.Verify run command; Check motor and drive wiring; Inspect motor.
Overcurrent fault (OC).Motor overload; Short circuit; Rapid acceleration.Reduce load; Check motor/cables for shorts; Increase acceleration time.
Sobrevoltage fault (OV).Volumen de entrada elevadotage; Rapid deceleration.Comprobar o vol. de entradatage; Increase deceleration time; Install braking resistor if needed.

7. Especificacións

Key technical specifications for the Yaskawa V1000 AC Drive (CIMR-VU2A0006FAA):

8. Garantía e soporte

For detailed warranty information, please refer to the official Yaskawa warranty statement or contact your authorized Yaskawa distributor.

For technical support, service, or to obtain a full copy of the V1000 technical manual, please visit the official Yaskawa websitio ou póñase en contacto co seu departamento de atención ao cliente.

Yaskawa Electric Corporation
Websitio: www.yaskawa.com

Documentos relacionados - CIMR-VU2A0006FAA

Preview YASKAWA AC Drive L1000A: Quick Start Guide for Elevator Applications
This Yaskawa AC Drive L1000A Quick Start Guide provides essential information for the safe and effective installation, wiring, and initial setup of AC drives for elevator applications. It covers critical safety precautions, mechanical and electrical installation, keypad operation, and startup procedures.
Preview Yaskawa AC Drive - A1000 High Frequency Custom Software Supplement
This document supplements the Yaskawa A1000 Quick Start Guide and Technical Manual, detailing modifications and new functions for the High Frequency Custom Software. It covers changes to parameters, functions, and application notes for high-speed motor applications.
Preview YASKAWA AC Drive A1000 Quick Start Guide
Quick Start Guide for the YASKAWA AC Drive A1000 series, a high-performance vector control drive. This manual provides essential information for safe installation, wiring, initial setup, operation, and troubleshooting of industrial AC drives.
Preview Yaskawa V1000 to GA500 AC Drive Transition Guide
A comprehensive guide for OEMs, integrators, and end-users transitioning from Yaskawa V1000 series AC drives to the Yaskawa GA500 AC drives. This document covers model identification, drive selection, dimensions, wiring, and branch circuit protection.
Preview Yaskawa V7 & V74X Drives Modbus Communication Manual
Guide to Modbus communication for Yaskawa V7 and V74X AC drives, covering network setup (RS-232, RS-422, RS-485), parameter access, message formats, and troubleshooting for industrial automation.
Preview Yaskawa AC Drive V1000 Option BACnet MS/TP Installation & Technical Manual
Detailed installation and technical guide for the Yaskawa AC Drive V1000 SI-B3/V BACnet MS/TP option, covering setup, networking, and troubleshooting for industrial automation.