Introdución
This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Información de seguridade
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Este produto está deseñado só para uso en interiores.
- Do not connect multiple power strips together.
- Ensure the power strip is properly grounded.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Manter lonxe da auga e de ambientes con alta humidade.
- Ensure proper ventilation when installed in a rack.
Contido do paquete
Verificar que todos os elementos estean presentes e sen danos:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Manual de usuario
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Produto rematadoview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Imaxe: Unha chea view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Características principais:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Imaxe: Unha detallada view of the angled Schuko power plug, which connects the power strip to the main power source.
Configuración e instalación
- Unpack the Power Strip: Retire con coidado a regleta da súa embalaxe. Inspeccione se hai algún sinal de danos.
- Escolla lugar de montaxe: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Conectar á fonte de enerxía: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Conectar dispositivos: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Image: A partial view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Operación
- Encendido: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Protección contra sobrecarga: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Apagado: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Mantemento
- Limpeza: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Inspección: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Ventilación: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Resolución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| Sen corrente nas tomas de corrente. | O interruptor automático disparou. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| Sen corrente nas tomas de corrente. | Power strip not plugged in. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Se o problema persiste despois de intentar estas solucións, póñase en contacto co servizo de atención ao cliente.
Especificacións
- Modelo: I-CASE STRIP-12SH
- Marca: Techly Professional
- Puntos de venda: 12 x Schuko (Type F) 45° angled with earth
- Plug de entrada: Angled Schuko (Type F)
- Cable: H05VV-F 3G 2.5 mm²
- Lonxitude do cable: 3 metros
- Valoración eléctrica: 16 A, 250 V CA
- Capacidade de carga máxima: 3.5 kW
- Dimensións (L x W x H): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Peso: 1795 gramos
- Material: Aluminum (body), Black (finish)
- Característica especial: Mountable (vertical rack installation)
- Certificacións: CE, RAEE
Información da garantía
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Política de devolución: O gañador da Buybox indica unha política de devolución de 30 días (reembolso/substitución).
Atención ao cliente
For technical assistance or further inquiries, please visit the official Techly websitio ou póñase en contacto co seu comerciante.
Fabricante: TECHLY PROFESSIONAL
Websitio: www.techly.com (Hypothetical link, as not provided in JSON)