1. Introdución
The Renogy LCD Remote Control Module is designed for exclusive use with specific Renogy 1000W, 2000W, and 3000W pure sine wave inverter chargers. This module enables remote monitoring of your inverter charger's performance, displaying critical information such as AC input and output voltage, output frequency, and battery voltage. Its flush-mountable design allows for convenient placement, providing easy access to the power saver switch without needing to access the main inverter charger unit directly.
Nota de compatibilidade: This LCD remote is compatible with Renogy inverter charger ASINs: B01MS9EI8Q, B01MUCN1WJ, B07CZQC22R. It is non compatible with newer Renogy inverter chargers that feature an integrated LCD display (e.g., ASINs: B07PQR8HVQ, B07PNGVMZK).
2. Información de seguridade
AVISO: This unit contains high internal voltage. Read and understand all instructions thoroughly before operating or installing this unit. Do not open or disassemble the unit to avoid serious injury or death from fire, explosion, or electrical shock. For any troubleshooting needs, contact the Renogy technical support team at 1-800-330-8678.
3. Produto rematadoview
The Renogy LCD Remote Control Module provides essential monitoring and control functions for your compatible inverter charger. Key features include:
- Remote on/off switch for Renogy 1000W, 2000W, and 3000W pure sine wave inverter chargers.
- Flush-mountable design for clean and simple installation.
- Displays AC input and AC output voltage, output frequency, and battery voltage.
- LED indicator light and control knobs for easy readability and operation.
- Includes a 10-meter (32.8 ft) long RJ45 connector cable for remote hookup.

Figura 3.1: Fronte view of the Renogy LCD Remote Control Module, showing the display, power switch, and warning label.

Figura 3.2: Lateral view of the Renogy LCD Remote Control Module, highlighting the RJ45 communication port.
4. Configuración e instalación
The Renogy LCD Remote Control Module is designed for flush mounting, providing a clean and integrated appearance. Follow these steps for installation:
- Escolle unha localización: Select a convenient, dry, and well-ventilated location for flush mounting the remote module. Ensure the chosen location is within 10 meters of your compatible Renogy inverter charger.
- Preparar a apertura: Carefully cut an opening in the mounting surface that matches the dimensions of the remote module for a flush fit. Refer to the product dimensions in the Specifications section for precise measurements.
- Connect the RJ45 Cable: Connect one end of the provided 10-meter RJ45 communication cable to the RJ45 port on the back of the remote control module.
- Connect to Inverter Charger: Route the other end of the RJ45 cable to your compatible Renogy inverter charger and plug it into the designated remote port. Ensure a secure connection at both ends.
- Asegurar o módulo: Insert the remote module into the prepared opening and secure it using appropriate fasteners (not included) through the mounting holes on the module's faceplate.

Figure 4.1: The 10-meter RJ45 communication cable included with the remote module.
5. Instrucións de funcionamento
Once installed and connected, the Renogy LCD Remote Control Module provides real-time monitoring and control:
- Interruptor de alimentación: The remote features a three-position switch:
- Power Saver On: Activates the power saver mode on the inverter charger, reducing standby power consumption.
- Unit Off: Turns off the inverter charger.
- Power Saver Off: Disables the power saver mode, allowing the inverter charger to operate at full capacity.
- Pantalla LCD: The LCD screen will display various operational parameters of your inverter charger, including:
- Vol. De entrada CAtage
- Saída CA Voltage
- Frecuencia de saída
- Batería Voltage
- Indicador LED: An LED indicator light provides quick visual status of the inverter charger's operation.
- Mandos de control: Use the control knobs (if present on your specific remote version) to navigate through display menus or adjust settings as per your inverter charger's capabilities.
6. Mantemento
The Renogy LCD Remote Control Module requires minimal maintenance. To ensure optimal performance and longevity:
- Limpeza: Keep the module clean by wiping it with a soft, dry cloth. Avoid using abrasive cleaners or solvents.
- Comprobación de conexión: Periodically inspect the RJ45 cable and its connections to ensure they are secure and free from damage.
- Condicións ambientais: Ensure the module is not exposed to extreme temperatures, direct sunlight, or excessive moisture, which could affect its performance and lifespan.
7 Solución de problemas
If you encounter issues with your Renogy LCD Remote Control Module, consider the following troubleshooting steps:
- Sen pantalla/alimentación:
- Verify that the RJ45 cable is securely connected to both the remote module and the inverter charger.
- Ensure the inverter charger itself is powered on and functioning correctly.
- Comprobe o cable por se hai danos visibles.
- Lecturas incorrectas:
- Confirm that the remote module is compatible with your specific inverter charger model (refer to the Introduction section).
- Ensure the inverter charger is operating within its normal parameters.
- O control remoto non responde:
- Cycle the power on the inverter charger (turn off, wait a few minutes, then turn back on).
- Ensure the remote's power switch is in the desired position.
If problems persist after attempting these steps, please contact Renogy technical support for further assistance.
8. Especificacións
| Característica | Especificación |
|---|---|
| Número de modelo | RNG-INVT-C-RC |
| Dimensións do produto | 7.85 x 3.75 x 1.25 polgadas (19.9 x 9.5 x 3.2 cm) |
| Peso do elemento | 13.6 onzas (385.6 g) |
| Lonxitude do cable de comunicación | 10 metros (32.8 pés) |
| Parámetros de visualización | Vol. De entrada CAtage, Vol. de saída de CAtage, Output Frequency, Battery Voltage |
| Compatibilidade | Renogy 1000W, 2000W, 3000W Pure Sine Wave Inverter Chargers (specific models) |
9. Garantía e soporte
For warranty information regarding your Renogy LCD Remote Control Module, please refer to the user manual of your main Renogy inverter charger or visit the official Renogy websitio. Os termos e condicións da garantía poden variar.
Soporte técnico: If you require technical assistance, have questions about installation, operation, or troubleshooting, please contact Renogy's customer support team:
- Teléfono: 1-800-330-8678
- Websitio: Visita o sitio web oficial de Renogy website for additional resources, FAQs, and contact options.





