Extech ET60

Extech ET60 Seven Range Vol.tagManual do usuario do comprobador de continuidade e electrólise con NCV

1. Introdución

This manual provides detailed instructions for the safe and effective operation of the Extech ET60 Seven Range Voltage & Continuity Tester with Non-Contact Voltage (NCV) detection. The ET60 is a versatile tool designed for electrical testing, featuring AC/DC voltage indication, continuity testing, and a built-in flashlight.

Lea este manual detidamente antes de usalo e consérvelo para futuras consultas.

2. Información de seguridade

AVISO: Electrical testing can be hazardous. Always follow safety precautions to avoid injury or damage to the device.

  • Ensure the tester is in good working condition before each use.
  • Do not use the tester if it appears damaged or if the test leads are compromised.
  • Always wear appropriate personal protective equipment (PPE), such as safety glasses and insulated gloves.
  • Verify the tester's operation on a known live circuit before testing an unknown circuit.
  • The ET60 is rated for CAT III-600V. Do not exceed these voltage límites.
  • Do not attempt to repair or modify the device. Refer servicing to qualified personnel.

3. Produto rematadoview

The Extech ET60 is a handheld voltage and continuity tester. It features a robust, rubberized double-molded housing for durability and grip. Key components include:

  • Unidade principal: Houses the display, controls, and NCV sensor.
  • Pistas de proba: Integrated black and red test leads with probe tips.
  • Voltage Indication LEDs: Display AC and DC voltage niveis.
  • Indicador de continuidade: Audible and visual alert for continuity.
  • Sensor NCV: Para non contacto voltage detección.
  • Lanterna: Integrated for illumination in dark areas.
Extech ET60 Voltage and Continuity Tester with NCV and test leads

Figura 1: Extech ET60 Voltage and Continuity Tester. The image shows the main unit with its display indicating voltage ranges and NCV sensor, along with the attached black and red test leads.

4. Configuración e instalación da batería

The Extech ET60 requires 2 AAA batteries for operation. These are typically included with the device.

  1. Localice a tapa do compartimento das baterías na parte traseira do probador.
  2. Use a suitable tool (e.g., a small screwdriver) to open the battery compartment.
  3. Insira 2 pilas AAA, asegurándose de manter a polaridade correcta (+/-) como se indica no interior do compartimento.
  4. Peche ben a tapa do compartimento da batería.
  5. Test the unit by pressing the flashlight button or by performing a quick continuity check on a known circuit.

5. Instrucións de funcionamento

5.1. AC Voltage Indicación

The ET60 indicates AC voltage across seven ranges. When connected to an AC circuit, the corresponding LED(s) will illuminate.

  • Connect the red and black test leads to the points where AC voltage hai que medir.
  • The tester will vibrate, and the LEDs corresponding to the detected voltage range will light up.
  • AC voltage ranges: 24V, 120V, 208V, 240V, 277V, 480V, 600V.
  • AC bandwidth: 45 to 66Hz.

5.2. DC Voltage Indicación

The ET60 indicates DC voltage across seven ranges. When connected to a DC circuit, the corresponding LED(s) will illuminate.

  • Connect the red and black test leads to the points where DC voltage is to be measured, observing polarity.
  • The tester will vibrate, and the LEDs corresponding to the detected voltage range will light up.
  • DC voltage ranges: 6V, 12V, 24V, 36V, 48V, 110V, 220V.

5.3. Proba de continuidade

The continuity test function checks for a complete electrical path between two points.

  • Ensure the circuit under test is de-energized before performing a continuity test.
  • Touch the red and black test leads to the two points you wish to test for continuity.
  • If continuity is detected, the tester will emit an audible beep and a visual alert (LED).

5.4. Vol. sen contactotagDetección e (NCV).

The NCV feature allows for quick detection of live AC voltage without direct contact with conductors.

  • Hold the NCV sensor tip (top of the tester) near the conductor or outlet you suspect is live.
  • Se AC voltage (90 to 1000Vac) is detected, the NCV indicator will illuminate, and an audible alert may sound.
  • This feature is for preliminary detection and should be confirmed with direct contact voltage medición.

5.5. Función da lanterna

The built-in flashlight assists in illuminating dark work areas.

  • Press the flashlight button (if present, or refer to device markings) to turn the flashlight on or off.

6. Mantemento

  • Limpeza: Wipe the tester with a dry, clean cloth. Do not use abrasive cleaners or solvents.
  • Substitución da batería: Replace batteries when the low battery indicator appears or if the tester's performance degrades. Refer to Section 4 for battery installation.
  • Almacenamento: Store the tester in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods to prevent leakage.
  • Inspección: Regularly inspect the test leads and housing for any signs of damage, cracks, or frayed insulation. Do not use a damaged tester.

7 Solución de problemas

ProblemaCausa posibleSolución
O probador non se acende.Baterías gastadas ou instaladas incorrectamente.Substitúa as pilas, asegurándose de que a polaridade sexa correcta.
Vol. imprecisotage lecturas.Low battery, damaged leads, or incorrect application.Replace batteries. Inspect leads for damage. Ensure proper contact with the circuit.
A proba de continuidade falla nun circuíto que se sabe que está en bo estado.Low battery, poor contact, or internal fault.Replace batteries. Ensure firm contact with test points. If problem persists, contact support.
NCV non detecta volumetage.Voltage too low, shielded wire, or NCV sensor not positioned correctly.Garantir voltage is within 90-1000Vac range. Try different angles. Confirm with direct contact measurement.

8. Especificacións

  • Modelo: ET60
  • Vol. ACtage Indicación: 24 V, 120 V, 208 V, 240 V, 277 V, 480 V, 600 V
  • DC Voltage Indicación: 6 V, 12 V, 24 V, 36 V, 48 V, 110 V, 220 V
  • AC Bandwidth: 45 a 66 Hz
  • Proba de continuidade: Audible and visual alert
  • Vol. Sen contactotagDetección de e (NCV): 90 a 1000 Vca
  • Clasificación de seguridade: CAT III-600V
  • Fonte de enerxía: 2 pilas AAA (incluídas)
  • Dimensións (L x W x H): Aproximadamente 5.2 x 1.6 x 11.6 polgadas (13.2 x 4.1 x 29.5 cm)
  • Peso: Aproximadamente 8 onzas (227 gramos)
  • Compoñentes incluídos: ET60 VoltagManual do usuario do probador electrónico

9. Garantía e soporte

Extech Instruments provides a limited warranty for this product. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Extech websitio.

For technical support, service, or replacement parts, please contact Extech Customer Service:

  • Websitio: www.extech.com
  • Consulte o websitio para obter información de contacto e recursos de asistencia actuais.

Documentos relacionados - ET60

Preview Extech ET40 Heavy Duty Continuity Tester User Manual
User manual for the Extech ET40 Heavy Duty Continuity Tester. Learn how to safely and effectively test continuity of non-energized components, fuses, switches, relays, wiring, and circuit boards.
Preview Extech CT20 Continuity Tester Pro User Manual - Features, Specifications, and Operation
Comprehensive user manual for the Extech CT20 Continuity Tester Pro. Learn about its features, specifications, safety precautions, local continuity testing, and advanced remote continuity and wire identification capabilities.
Preview Extech DV30 AC Voltage Manual de usuario do detector
User manual for the Extech DV30 AC Voltage Detector, detailing safety precautions, operation, specifications, battery replacement, disposal, warranty, and contact information.
Preview Extech ET20 Indicador dual Voltage Manual de usuario do detector
Manual de usuario do indicador dual Extech ET20 Vol.tagDetector e, un voltaxe CA/CC de 2 víastagComprobador electrónico (100-250 V). Ofrece información sobre o funcionamento, a garantía e o servizo técnico.
Preview Extech DV690 High Voltage Detector User Manual | Safety and Operation Guide
Comprehensive user manual for the Extech DV690 High Voltage Detector. Learn about product features, operation, safety precautions, specifications, and support for detecting AC voltage from 100V to 69kV.
Preview Guía do usuario da serie Extech EX650: Cl dixital de 600 A con verdadeiro RMSamp Metros
Guía completa do usuario para a serie Extech EX650 de termorreguladores dixitais de verdadeiro RMS de 600 Aamp medidores, que abarcan os modelos EX650 e EX655. Obtén información sobre o funcionamento, as características, a seguridade e as especificacións para obter medicións precisas de volume CA/CCtage, corrente, resistencia e outras medicións.