1. Introdución

This manual provides essential information for the proper installation, operation, and maintenance of the Notifier FAPT-851 ACCLIMATE Multi-Sensor. The FAPT-851 is an intelligent, addressable multi-sensor designed for use with compatible fire alarm control panels. It combines photoelectric smoke and fixed-temperature heat detection to provide enhanced fire protection and reduce nuisance alarms.

Please read this manual thoroughly before installation and retain it for future reference. Adherence to these instructions is crucial for the reliable performance of the device.

2. Información importante de seguridade

Observe sempre as seguintes precaucións de seguridade:

  • Installation and wiring must be performed by qualified personnel in accordance with all national and local codes and regulations.
  • Disconnect all power from the fire alarm control panel before installing or servicing the sensor.
  • Do not paint the sensor. Paint can interfere with proper operation.
  • Test the sensor regularly as described in the Maintenance section.
  • This device is not intended for use in hazardous locations.

3. Contido do paquete

Verifica que todos os elementos estean presentes no paquete:

  • Notifier FAPT-851 ACCLIMATE Multi-Sensor
  • Installation and Maintenance Instructions (this document)
Notifier FAPT-851 Multi-Sensor in its retail box

Figura 3.1: The Notifier FAPT-851 ACCLIMATE Multi-Sensor packaged in its brown cardboard box. The label on the box clearly displays 'NOTIFIER by Honeywell', 'FAPT-851', 'ACCLIMATE MULTI-SENSOR', and the UPC 0783863021138.

4. Configuración e instalación

4.1 Montaxe

The FAPT-851 sensor is designed for flange mounting. Ensure the mounting location complies with local fire codes and provides optimal coverage.

  1. Select a suitable mounting base (sold separately) compatible with the FAPT-851.
  2. Secure the mounting base to the ceiling or wall using appropriate fasteners.
  3. Align the sensor with the mounting base and rotate clockwise until it clicks into place.

4.2 Cableado

Wiring must be performed according to the fire alarm control panel's installation manual and all applicable codes. The FAPT-851 is an addressable device and requires connection to an intelligent signaling line circuit (SLC).

  • Ensure power to the SLC is disconnected before wiring.
  • Connect the SLC wiring to the terminals on the mounting base as indicated in the base's instructions.
  • Set the sensor's address using the rotary switches on the back of the sensor before mounting it to the base.
Abaixo view of the Notifier FAPT-851 Multi-Sensor

Figura 4.1: The underside of the Notifier FAPT-851 sensor, showing the rotary address switches and the label with model number, UL listing, and wiring information. This view is critical for setting the device address and understanding connection points.

Notifier FAPT-851 Multi-Sensor and instruction manual in box

Figura 4.2: The Notifier FAPT-851 sensor removed from its box, alongside the folded installation and maintenance instructions. This image shows the context of the manual within the product packaging.

5. Instrucións de funcionamento

5.1 Operación normal

During normal operation, the sensor communicates with the fire alarm control panel. The LED indicator on the sensor will flash periodically (e.g., every few seconds) to indicate normal polling by the control panel. Refer to your control panel's manual for specific LED flash patterns.

5.2 Indicación de alarma

When the sensor detects smoke or heat exceeding its programmed thresholds, it will enter an alarm state. The LED indicator on the sensor will illuminate steadily (e.g., red) to indicate an alarm condition. The control panel will also register the alarm and activate appropriate notification appliances.

5.3 Trouble Indication

If the sensor experiences a fault or malfunction (e.g., contamination, internal error), it will report a trouble condition to the control panel. The LED indicator may flash in a specific pattern (e.g., amber) or remain off, depending on the nature of the trouble. Consult the control panel's manual for trouble code interpretation.

6. Mantemento

Regular maintenance ensures the continued reliable operation of your FAPT-851 sensor.

6.1 Limpeza

Dust and debris can accumulate on the sensor, potentially affecting its performance. Clean the sensor annually or as needed:

  1. Disconnect power to the fire alarm control panel.
  2. Gently twist the sensor counter-clockwise to remove it from its mounting base.
  3. Use a soft brush or a vacuum cleaner with a soft brush attachment to remove dust from the sensor's vents and chamber.
  4. Limpe o exterior cun lixeiro damp pano. Non use produtos químicos ou disolventes agresivos.
  5. Reattach the sensor to its base by aligning and twisting clockwise until it locks.
  6. Restore power to the control panel and verify normal operation.

6.2 Probas

Test the sensor after installation and periodically thereafter (e.g., monthly or quarterly, as required by local codes):

  1. Notify appropriate personnel that the fire alarm system will be tested.
  2. Initiate a functional test using approved test methods (e.g., canned smoke for smoke detection, heat gun for heat detection).
  3. Verify that the sensor goes into alarm and the control panel registers the alarm.
  4. Reset the fire alarm control panel.
Notifier FAPT-851 Multi-Sensor with an orange protective cover

Figura 6.1: The Notifier FAPT-851 sensor with an orange protective cover installed. This cover is typically used during construction or painting to prevent contamination of the sensor chamber, and must be removed for proper operation.

7 Solución de problemas

Consulta a táboa seguinte para ver os problemas comúns e as súas posibles solucións.

ProblemaCausa posibleSolución
O sensor non respondeIncorrect wiring, incorrect address, power issue, faulty sensor.Check wiring connections, verify sensor address, confirm power to SLC, replace sensor if necessary.
Alarmas molestasDust/debris in chamber, sensor located in high-smoke/steam area, environmental factors.Clean sensor (Section 6.1), relocate sensor if possible, adjust sensitivity settings on control panel if applicable.
Trouble signal on control panelSensor fault, communication error, contamination.Check control panel for specific trouble code, clean sensor, verify wiring, replace sensor if fault persists.

8. Especificacións

Technical specifications for the Notifier FAPT-851 ACCLIMATE Multi-Sensor:

CaracterísticaDetalle
Número de modeloFAPT-851
FabricanteHONEYWELL
MaterialMetal, Plástico
Tipo de montaxeMontaxe de brida
Precisión de medición±1.5°C (for heat detection)
Dimensións do paquete4 x 4 x 2 polgadas
EstiloClásico

9. Garantía e soporte

For information regarding the product warranty, please refer to the documentation provided with your fire alarm control panel or contact Notifier customer support directly. Notifier provides technical support and resources to assist with installation, operation, and troubleshooting.

For technical assistance or to report issues, please visit the official Notifier website or contact your authorized Notifier distributor.

Documentos relacionados - FAPT-851

Preview Manual de instalación e mantemento do detector de fume para condutos de aire Notifier DHX-501
Este manual proporciona procedementos detallados de instalación, cableado, probas e mantemento para a carcasa do detector de fume para condutos de aire intelixente Notifier DHX-501. Inclúe descricións xerais, listas de compoñentes, avisos de seguridade, instalación paso a paso, mantemento periódico e especificacións para o seu uso cos cabezales detectores Notifier CPX-551 e SDX-551.
Preview Instalación e mantemento do sensor fotoeléctrico de fume intelixente FSP-851R
Instrucións de instalación e mantemento para o sensor fotoeléctrico intelixente de fume FSP-851R con capacidade de proba remota, deseñado para aplicacións en condutos. Inclúe especificacións, guías de cableado, procedementos de proba e instrucións de limpeza.
Preview Panel de control de alarma contra incendios direccionable intelixente NOTIFIER NFS-320C | Ficha técnica e características
Explore o panel de control de alarma contra incendios direccionable intelixente NOTIFIER NFS-320C. Esta ficha técnica abrangue as súas funcións avanzadas, a detección intelixente ONYX, o protocolo FLASHSCAN, as capacidades de rede e a ampla compatibilidade de dispositivos.
Preview Notifier 30-3003 Explosion-Proof Smoke Detector: Features and Specifications
Discover the features, applications, and technical specifications of the Notifier 30-3003 Explosion-Proof Smoke Detector, designed for hazardous industrial environments.
Preview Ficha técnica do sistema de alarma contra incendios direccionable intelixente Notifier NFS-320
Ficha técnica completa para o sistema de alarma contra incendios direccionable intelixente Notifier NFS-320, que detalla as súas características, capacidades de detección intelixente, protocolo FlashScan, especificacións do sistema, dispositivos compatibles e aprobacións de axencias.
Preview Instalación e mantemento dos sensores fotoeléctricos intelixentes de fume Notifier FSP-951 e FSP-951-IV
This document provides installation and maintenance instructions for Notifier FSP-951 and FSP-951-IV intelligent photoelectric smoke sensors. It details product specifications, wiring guidelines, testing procedures, cleaning methods, and compliance information for fire detection systems.