1. Introdución

This manual provides essential information for the safe and effective use of the Delfield MCP00143 Temperature Danfoss Control. This genuine OEM replacement part is designed for commercial foodservice equipment, reflecting Delfield's extensive industry experience. Please read this manual thoroughly before installation and operation to ensure proper function and longevity of the unit.

Delfield MCP00143 Temperature Danfoss Control, front view with coiled capillary tube

Figura 1: Máisview of the Delfield MCP00143 Temperature Danfoss Control, showing the main housing and the coiled capillary tube.

2. Información de seguridade

Always adhere to local electrical codes and safety regulations. Installation and servicing should only be performed by qualified personnel. Disconnect power before performing any work on the control unit or associated equipment. Failure to follow these instructions may result in property damage, serious injury, or death.

3. Descrición e características do produto

The Delfield MCP00143 is a genuine OEM replacement temperature control unit manufactured by Danfoss, specifically designed for Delfield commercial foodservice equipment. This control is essential for maintaining precise temperature regulation within refrigeration systems.

Características principais:

4. Configuración e instalación

Installation of the Delfield MCP00143 Temperature Danfoss Control requires technical expertise. It is strongly recommended that installation be performed by a certified refrigeration technician or qualified electrician to ensure correct wiring, proper sensor placement, and system integrity.

Pasos de instalación (orientación xeral):

  1. Desconexión de alimentación: Ensure all power to the equipment is completely disconnected and locked out before beginning any work.
  2. Acceso: Gain access to the existing temperature control unit within the equipment.
  3. Eliminación: Carefully disconnect and remove the old control unit, noting all wiring connections and the routing of the capillary tube.
  4. Montaxe: Mount the new Delfield MCP00143 control unit securely in the designated location.
  5. Cableado: Connect the electrical wiring to the new control unit according to the equipment's wiring diagram. Ensure all connections are secure and correct.
  6. Capillary Tube Placement: Carefully route and secure the capillary tube to the sensing location within the refrigeration system. Avoid kinks or sharp bends in the tube.
  7. Proba: After installation, restore power and test the control unit's functionality and temperature sensing accuracy.
Delfield MCP00143 Temperature Danfoss Control, side view showing adjustment dial

Figura 2: Lateral view of the control unit, highlighting the temperature adjustment dial and mounting screws.

5. Instrucións de funcionamento

The Delfield MCP00143 Temperature Danfoss Control is designed for straightforward operation once installed. Its primary function is to regulate the temperature of the connected refrigeration system.

Axuste da temperatura:

The control unit will automatically cycle the refrigeration compressor on and off to maintain the set temperature within the specified differential.

6. Mantemento

Regular maintenance helps ensure the longevity and optimal performance of your Delfield MCP00143 Temperature Danfoss Control. Always disconnect power before performing any maintenance.

Delfield MCP00143 Temperature Danfoss Control, bottom view showing capillary tube connection

Figura 3: Abaixo view of the control unit, illustrating the connection point for the capillary tube.

7 Solución de problemas

If you experience issues with your Delfield MCP00143 Temperature Danfoss Control, consider the following common troubleshooting steps. For complex issues, contact a qualified technician.

ProblemaCausa posibleSolución
Unit not responding / No powerNo power supply; Loose wiring; Blown fuse/tripped breakerCheck power supply to equipment; Inspect wiring connections; Reset breaker or replace fuse.
Lectura incorrecta da temperaturaSensor bulb improperly placed or damaged; Control unit calibration issueVerify sensor bulb placement; Inspect capillary tube for damage; Consult a technician for calibration.
Compressor constantly running or not runningTemperature setting too high/low; Control unit malfunction; Refrigeration system issueAdjust temperature setting; If issue persists, contact a qualified refrigeration technician.
Delfield MCP00143 Temperature Danfoss Control, angled view showing electrical connections

Figura 4: En ángulo view of the control unit, providing a clearer look at the electrical connection points.

8. Especificacións

AtributoDetalle
FabricanteDELFIELD
Número de modelo do artigoMCP00143
Nome do modelomcp00143
ASINB07H7WDGGF
Control de temperatura axustableSi
Especificación MetOEM
Peso do elemento1.1 libras (aprox. 498.95 g)
Dimensións do paquete25.91 x 25.91 x 20.83 cm

9. Garantía e soporte

As a genuine OEM replacement part, the Delfield MCP00143 Temperature Danfoss Control is manufactured to high standards. For specific warranty information or technical support, please refer to the documentation provided with your original Delfield equipment or contact Delfield customer service directly. Using genuine OEM parts helps ensure continued warranty coverage for your equipment.

For further assistance, you may visit the official Delfield website or contact their authorized service providers.

Documentos relacionados - MCP00143

Preview Delfield DSL Pass-Thru Series DSLFPT Original Parts List
This document provides the original parts list for the Delfield DSL Pass-Thru Series DSLFPT model. It includes part numbers, full descriptions, and notes for service and cross-referencing older part numbers with new ones.
Preview Delfield GCF2P, GBF2P, GBSF2P R290 Series Parts List
Original parts list for Delfield GCF2P, GBF2P, and GBSF2P R290 series commercial refrigeration units. Includes part numbers, descriptions, and revision notes for various components.
Preview Guía de programación do temporizador de desconxelación AIR-O-TRONICS
Guía do usuario para o temporizador de desconxelación AIR-O-TRONICS, que detalla a configuración dos interruptores DIP para a duración do desconxelación e o tempo de ciclo, con secuencias operativas e información de cableado.
Preview Delfield DSLF Reach-in Series® Current Parts List
Official parts list for the Delfield DSLF Current Reach-in Series refrigeration units, detailing part numbers, descriptions, and notes for maintenance and repair.
Preview Delfield GC, GB & GBS Series GCF1P, GBF1P & GBSF1P - R290 Current Parts List
This document provides the official parts list for Delfield GC, GB, and GBS Series commercial refrigeration units, specifically models GCF1P, GBF1P, and GBSF1P utilizing R290 refrigerant. It details component part numbers, full descriptions, and relevant notes for identification and cross-referencing, including information on older part numbers.
Preview Refrigeradores e conxeladores Delfield series 6000XL e 6100XL: Manual de servizo, instalación e coidado
This manual provides comprehensive service, installation, and care instructions for Delfield 6000XL and 6100XL Series Reach-In Refrigerators and Freezers. It covers specifications, operation, maintenance procedures, wiring diagrams, replacement parts, labor guidelines, and warranty information.