Elitech ILD-100H

Manual do usuario do detector de fugas de refrixerante Elitech ILD-100H HVAC

Model: ILD-100H | Brand: Elitech

1. Introdución e finalview

The Elitech ILD-100H is an advanced HVAC refrigerant leak detector designed for precise and efficient detection of various halogenated refrigerants. Utilizing a heated diode sensor, it offers enhanced accuracy and reliability compared to traditional sensors. This manual provides detailed instructions for the proper setup, operation, maintenance, and troubleshooting of your ILD-100H detector, ensuring optimal performance and longevity.

This device is suitable for detecting a wide range of refrigerants, including CFCs, HFCs, HCFCs, HCs, HFOs, and mixed refrigerants such as R11, R22, R404a, R410a, R600a, R1234yf, and various blends like AZ-50, HP62, and MP39. It boasts an immediate response time, making leak detection quick and effective.

2. Características clave

  • Heated Diode Sensor: Provides superior accuracy for all halogenated refrigerants, ensuring reliable detection results.
  • Pantalla TFT: The innovative TFT screen offers clear and easy-to-read information, including sensitivity levels, leakage alerts, and battery status, enhancing operational clarity.
  • Alta sensibilidade: Features adjustable sensitivity with High, Medium, and Low levels. The maximum sensitivity reaches up to 0.1 oz/yr, allowing for the detection of even minute leaks.
  • Operación rápida: Equipped with two intuitive buttons on the front panel for rapid adjustment of sensitivity and direct muting of the buzzer, simplifying user interaction.
  • Broad Refrigerant Compatibility: Capable of detecting all types of halogenated refrigerants, including HFCs (R134a, R410A, R407C, R417A, R404A, R507, R23, R508A, R508B, R152A, R32), HCFCs (R22, R123, R124, R141b, R142b, R402A, R402B, R408A, R409A), CFCs (R11, R12, R13, R502, R503), PFCs (PFC-14, PFC-116, PFC-218), and HFOs (R-1234yf), as well as HCs (R50, R170, R290, R600, R600A, R1150, R1270).
Elitech ILD-100H Halogen Leak Detector highlighting adjustable sensitivity, audible & light alarm, immediate response, and two different modes.

Figura 2.1: Máisview of Elitech ILD-100H key features.

3. Compoñentes e dimensións do produto

Elitech ILD-100H with labeled components including flexible probe, UV LED, filter components, display screen, buttons, and buzzer.

Figure 3.1: Labeled components of the Elitech ILD-100H.

Elitech ILD-100H dimensions showing 7.9 inches height, 3.3 inches width, 1.5 inches depth, and a 14-inch probe length. Also lists max sensitivity, response time, battery, and compliance standards.

Figure 3.2: Physical dimensions and key performance specifications.

4. Configuración

  1. Desembalaxe: Carefully remove the Elitech ILD-100H and all accessories from the packaging. Inspect for any signs of damage.
  2. Carga da batería: The device includes a Lithium Metal battery. Before first use, ensure the battery is fully charged. Connect the appropriate charging cable (not specified in data, assume standard USB-C based on reviews) to the device and a power source. The TFT screen will indicate charging status.
  3. Sensor Preparation: Ensure the flexible probe and filter components are securely attached. The heated diode sensor requires a brief warm-up period after powering on.
Elitech ILD-100H Refrigerant Leak Detector, a handheld device with a flexible probe and a digital display.

Figure 4.1: Elitech ILD-100H ready for setup.

5. Instrucións de funcionamento

  1. Encendido: Press the 'ON/OFF' button to power on the device. The TFT screen will illuminate and display a warm-up countdown.
  2. Quecemento: Allow the device to complete its warm-up cycle (typically 20 seconds as seen in image). This ensures the heated diode sensor reaches optimal operating temperature for accurate detection.
  3. Seleccione Sensibilidade: Use the 'SENS' button to cycle through the sensitivity levels: High (H), Medium (M), and Low (L). Higher sensitivity is recommended for detecting smaller leaks or for initial scanning.
  4. Detección de fugas: Slowly move the flexible probe around suspected leak areas. The device will provide visual alerts on the TFT screen (e.g., bar graph, curve display) and an audible alarm when a leak is detected. The intensity of the alarm and display will increase with higher leak concentrations.
  5. Pinpoint vs. Curve Display: The TFT screen offers two display modes. The 'Pinpoint Display' helps in finding the exact leak location, while the 'Curve Display' assists in quickly identifying the general leak area.
  6. Mute Buzzer: Press the 'MUTE' button to silence the audible alarm if needed.
  7. Apagado: Press and hold the 'ON/OFF' button to power off the device after use.
Elitech ILD-100H display modes showing Pinpoint Display for exact leak location and Curve Display for general leak area.

Figure 5.1: Understanding the Pinpoint and Curve Display modes for leak identification.

Elitech ILD-100H detecting various halogenated refrigerants including HFC, HCFC, CFC, PFC, HFO, and HC types.

Figure 5.2: The ILD-100H's capability to detect a wide range of halogenated refrigerants.

Vídeo 5.1: Un overview of Elitech's AI HVAC/R tools, demonstrating the advanced capabilities and applications of their products, including the ILD-100H leak detector in action.

6. Mantemento

  • Limpeza: Regularly wipe the exterior of the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
  • Sensor and Filter Maintenance: The device features filter components (as shown in Figure 3.1). Refer to the full user manual (PDF link provided in product data) for specific instructions on cleaning or replacing the sensor and filter to maintain optimal performance.
  • Almacenamento: Store the detector in a cool, dry place away from direct sunlight and extreme temperatures when not in use.

7 Solución de problemas

If you encounter issues with your Elitech ILD-100H, consider the following common troubleshooting steps:

  • O dispositivo non se acende: Ensure the battery is fully charged. If the issue persists, try connecting the charger to confirm power supply.
  • Inaccurate Readings/No Detection: Check the sensor and filter for any obstructions or damage. Ensure the device has completed its warm-up cycle. Adjust sensitivity settings to a higher level if necessary.
  • Comportamento errático: Ensure the device is not exposed to strong electromagnetic interference. Try restarting the device.

For persistent issues or complex problems, please refer to the comprehensive user manual or contact Elitech customer support.

8. Especificacións

AtributoDetalle
MarcaElitech
Número de modeloILD-100H
EstiloHeated Diode Sensor
Fonte de enerxíaAlimentado por batería
CorHeated Diode Sensor Ild-100h
Dimensións do produto (P x A x A)1.5" x 3.3" x 7.9"
Peso do elemento2.46 libras
Tipo de alarmaAudible
Humidade de funcionamento85 por cento
Clasificación de temperatura superior20 graos centígrados
Tipo de sensorIR
MaterialPlástico
Sensibilidade máxima0.1 oz/yr
Tempo de respostaImmediate (within 1s)
Tipo de bateríaLithium Ion (1 Lithium Metal battery included)
Capacidade da batería3.7 V 3000 mAh
UsoHVAC systems, refrigerant leak detection
Normas de cumprimentoEN14624.5AE-162, SAE-2791, SAE-2913, CE
UPC704529988930, 704529989043

9. Garantía e soporte

The Elitech ILD-100H Refrigerant Leak Detector comes with a 1 ano de garantía desde a data de compra.

For any technical assistance, product inquiries, or warranty claims, Elitech offers 7x24 customer services. Please refer to the official Elitech website or the full user manual for contact details.

You can also download the complete user manual in PDF format for more detailed information: Descargar o manual de usuario (PDF)

Documentos relacionados - ILD-100H

Preview Manual de usuario del detector de corona Elitech WJL-6000S
Manual de usuario do detector de corona Elitech WJL-6000S, que proporciona instrucións detalladas sobre o funcionamento, a detección, a resolución de problemas e o mantemento para a detección de fugas de refrixerante en varios sistemas.
Preview Manual de usuario del detector de fugas de refrigerante por infravermellos Elitech ILD Series
Manual de usuario completo para os detectores de fugas de refrixerante por infravermellos da serie Elitech ILD (ILD-100, ILD-200, ILD-300), que abrangue as especificacións, o funcionamento, o mantemento e as características. Aprenda a detectar eficazmente as fugas de refrixerante con este dispositivo avanzado.
Preview Manual do usuario do detector de fugas por infravermellos Elitech ILD-100/ILD-200/ILD-300
Manual de usuario para os detectores de fugas de refrixerante por infravermellos da serie Elitech ILD (ILD-100, ILD-200, ILD-300). Ofrece información detallada sobre o funcionamento, as especificacións, as características e o mantemento para unha detección precisa das fugas de refrixerante.
Preview Manual do usuario do detector de fugas de refrixerante con diodo calefactado Elitech LD-100
Manual de usuario do detector de fugas de refrixerante por díodo calefactado Elitech LD-100, que detalla as súas características, funcionamento e mantemento.
Preview Manual do usuario do detector de fugas por diodos infravermellos e calefactados Elitech IR-200
Manual de usuario completo para o Elitech IR-200, un detector de fugas de dobre sensor con tecnoloxía de infravermellos e díodos calefactados. Coñece as súas especificacións, funcionamento, mantemento e características para detectar fugas de refrixerante.
Preview Elitech HLD-200 Manual de usuario del detector de fugas halógenas
This user manual provides comprehensive instructions for operating and maintaining the Elitech HLD-200 Halogen Leak Detector. It covers technical specifications, operation procedures, leak detection methods, troubleshooting, and maintenance tips for effective use in refrigeration and HVAC systems.