1. Introdución
This manual provides comprehensive instructions for the installation, setup, operation, and maintenance of the Subzero SZ-7569T Touch Sensitive Temperature Controller. Please read this manual thoroughly before using the device to ensure proper function and safety. Keep this manual for future reference.
2. Produto rematadoview
The Subzero SZ-7569T is a precise, touch-sensitive temperature controller designed for various industrial and scientific applications. It features a clear digital display and intuitive touch controls for easy temperature management.

Figure 1: Subzero SZ-7569T Front Panel
The image displays the front panel of the Subzero SZ-7569T temperature controller. It features a black casing with a bright red digital LED display showing '28°C'. To the left, the 'sub-zero' brand name is visible. On the right, there are touch-sensitive buttons for 'Up' (arrow), 'Power' (circle with line), 'PRG' (program) with a 'Down' arrow, and 'SET' (set). A snowflake icon is also visible next to the temperature reading, indicating a cooling function.
3. Especificacións
| Característica | Detalle |
|---|---|
| Marca | Sub Zero |
| Modelo | SZ-7569T |
| Fabricante | PVR Control |
| País de Orixe | India |
| Cor | Negro |
| Peso do elemento | 210 g |
| Dimensións do produto (LxWxH) | 10 x 6 x 4 cm |
| Voltage | 220 voltios (CA) |
| Tipo de visualización | Pantalla táctil |
4. Instalación
Proper installation is crucial for the accurate and safe operation of the temperature controller. It is recommended that installation be performed by a qualified technician.
- Desconexión de alimentación: Ensure all power to the installation area is disconnected before beginning any wiring.
- Montaxe: Mount the controller in a secure, dry location away from direct heat sources, excessive vibration, or corrosive environments. Ensure adequate ventilation.
- Cableado: Connect the power supply, temperature sensor, and controlled device (e.g., heater, cooler) to the appropriate terminals on the controller. Refer to the wiring diagram provided with the product packaging for specific connections. Ensure all connections are secure and correctly polarized.
- Colocación do sensor: Position the temperature sensor in the area where temperature control is required, ensuring it accurately reflects the desired measurement point and is not influenced by external factors.
- Conexión de alimentación: Once all wiring is complete and verified, restore power to the system.
Warning: Incorrect wiring can lead to device malfunction, damage, or electrical hazards. Always consult the detailed wiring diagram.
5. Configuración inicial
After installation, perform the following steps for initial setup:
- Encendido: Preme o ⏻ (Power) button to turn on the device. The display will illuminate.
- Check Sensor Reading: Verify that the display shows a plausible temperature reading. If an error code appears, refer to the Troubleshooting section.
- Configuración de acceso: Preme o SET button to enter the temperature setting mode.
- Adjust Setpoint: Usa o ⌃ (Arriba) e ⌄ (Down) buttons to adjust the desired temperature setpoint.
- Confirm Setpoint: Preme SET again to confirm the new setpoint and exit the setting mode.
- Program Mode (PRG): For advanced settings such as hysteresis, calibration, or alarm limits, press the PRG button. Navigate through parameters using the Up/Down arrows and confirm changes with SET. Consult the full programming guide for detailed parameter descriptions.
6. Funcionamento
The Subzero SZ-7569T operates automatically once the setpoint and parameters are configured. The display shows the current measured temperature.
- Visualización da temperatura: The large digital display continuously shows the current temperature measured by the sensor.
- Cooling/Heating Indicator: A snowflake icon (❅) or similar indicator will illuminate when the cooling or heating output is active, depending on the configured mode.
- Adjusting Setpoint During Operation: Prema brevemente SET, entón usa ⌃ (arriba) ou ⌄ (Down) to change the setpoint. Press SET de novo para gardar.
- Encendido/apagado: Manteña premido o ⏻ (Power) button for a few seconds to turn the device off or on.
7. Mantemento
Regular maintenance ensures the longevity and accuracy of your Subzero SZ-7569T temperature controller.
- Limpeza: Limpar a pantalla e casing cun suave, damp cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the touch panel or internal components.
- Inspección do sensor: Periodically check the temperature sensor for any signs of damage or corrosion. Ensure it is securely in place.
- Conexións: Occasionally inspect wiring connections to ensure they remain tight and free from corrosion.
- Verificación de calibración: If accuracy is critical, periodically verify the controller's readings against a calibrated reference thermometer. Recalibrate if necessary, following the instructions in the programming guide.
Caution: Always disconnect power before performing any maintenance that involves opening the device or accessing internal wiring.
8 Solución de problemas
This section addresses common issues you might encounter with the Subzero SZ-7569T.
| Problema | Causa posible | Solución |
|---|---|---|
| A pantalla está en branco | No power supply; Loose wiring; Device malfunction. | Check power connection; Verify wiring; Contact support if power is present and wiring is correct. |
| Lectura incorrecta da temperatura | Faulty sensor; Sensor incorrectly placed; Calibration error. | Check sensor connection and placement; Replace sensor if damaged; Perform calibration. |
| Controller not switching output | Setpoint not reached; Hysteresis setting too wide; Wiring issue; Device malfunction. | Verify setpoint and current temperature; Adjust hysteresis; Check output wiring; Contact support. |
| Os botóns non responden | Temporary software glitch; Physical damage to touch panel. | Power cycle the device; If issue persists, contact support. |
Se atopas algún problema que non aparece aquí ou se as solucións suxeridas non o resolven, ponte en contacto co servizo de atención ao cliente.
9. Garantía e soporte
The Subzero SZ-7569T Touch Sensitive Temperature Controller is covered by a standard manufacturer's warranty against defects in materials and workmanship. Please refer to the warranty card included with your product for specific terms and conditions, including the warranty period.
For technical support, service, or warranty claims, please contact PVR Control customer service. Ensure you have your product model number (SZ-7569T) and purchase details available when contacting support.
Fabricante: PVR Control
Modelo: SZ-7569T