Green Cell INV07

Green Cell INV07 300W/600W DC 12V to AC 230V Pure Sine Wave Inverter with UPS User Manual

1. Introdución

This manual provides essential information for the safe and efficient operation of your Green Cell INV07 Pure Sine Wave Inverter with UPS function. This device converts 12V DC power from a battery into 230V AC power, suitable for a wide range of electronic devices. It also features an Uninterruptible Power Supply (UPS) function, ensuring continuous power for critical applications like central heating pumps during outages.

The inverter delivers a continuous output of 300W and a peak power of up to 600W. It is designed for devices requiring a stable, pure sine wave power supply, similar to standard wall outlets.

2. Instrucións de seguridade

  • Le todas as instrucións: Before operating the inverter, read and understand all safety and operating instructions.
  • Ventilación: Asegúrese de que haxa unha ventilación axeitada arredor do inversor. Non bloquee as aberturas de ventilación.
  • Evita a humidade: Do not expose the inverter to rain, water, or excessive humidity.
  • Proper grounding: Always connect the inverter to a properly grounded 12V DC power source.
  • Protección contra sobrecarga: Do not exceed the inverter's rated continuous power output (300W) or peak power (600W). Overloading can damage the inverter and connected devices.
  • Conexión da batería: Connect the inverter directly to a 12V battery using the provided cables. The nominal line for cigarette lighter connection is limited to a maximum of 150W.
  • Vol. Altotage: The inverter produces high AC voltage. Treat it with the same caution as a standard wall outlet.
  • Nenos e animais: Manteña o inversor fóra do alcance dos nenos e das mascotas.
  • Mantemento: Só persoal cualificado debe realizar o mantemento ou as reparacións.

3. Contido do paquete

Verifica que todos os elementos estean presentes no paquete:

  • Green Cell INV07 Pure Sine Wave Inverter with UPS
  • Battery connection cables (red for positive, black for negative)
  • Fusibles de recambio
  • Manual de usuario
Green Cell INV07 Inverter package contents including the inverter, cables, fuses, and user manual.

Image: Green Cell INV07 Inverter and its included accessories: battery cables, spare fuses, and the user manual.

4. Produto rematadoview

Familiarize yourself with the inverter's components and ports.

Panel frontal

Front panel of the Green Cell INV07 Inverter showing AC output socket, USB port, power switch, and indicator lights.

Image: Front panel with AC output, USB port, power switch, and status indicators.

  • Toma de saída de CA: For connecting 230V AC devices.
  • Porto USB: For charging smaller devices like smartphones and tablets.
  • Interruptor de alimentación (aceso/apagado): To turn the inverter on or off.
  • Power Indicator (Green LED): Illuminates when the inverter is operating normally.
  • Fault Indicator (Red LED): Illuminates to indicate an error or fault condition.
  • Entrada AC: For connecting to a 230V AC mains supply when using the UPS function.

Panel traseiro

Rear panel of the Green Cell INV07 Inverter showing DC input terminals and cooling fan.

Image: Rear panel with DC input terminals and cooling fan.

  • DC Input Terminals (+ and -): For connecting to a 12V DC battery. Ensure correct polarity (red for +, black for -).
  • Ventilador de refrixeración: Automatically activates to dissipate heat during operation.

5. Configuración

Follow these steps to set up your Green Cell INV07 inverter:

  1. Colocación: Choose a dry, well-ventilated location for the inverter, away from direct sunlight, heat sources, and flammable materials. Ensure sufficient space for airflow around the cooling fan.
  2. Conexión da batería:
    • Connect the red cable to the positive (+) terminal of your 12V battery and the positive (+) DC input terminal on the inverter.
    • Connect the black cable to the negative (-) terminal of your 12V battery and the negative (-) DC input terminal on the inverter.
    • Asegúrate de que as conexións estean ben axustadas e seguras para evitar arcos eléctricos ou sobrequecemento.
  3. AC Mains Connection (for UPS function): If you intend to use the UPS function, connect the inverter's AC input to a standard 230V AC wall outlet using a suitable power cord.
  4. Conexión do dispositivo: Ensure the inverter's power switch is in the OFF position before connecting any devices. Plug your 230V AC devices into the AC output socket and/or USB devices into the USB port.
Arriba abaixo view of the Green Cell INV07 Inverter with power cable connected.

Imaxe: Arriba view of the inverter, illustrating its compact design and connection points.

6. Instrucións de funcionamento

  1. Encendido: After all connections are secure, switch the inverter's power switch to the ON position. The green Power LED should illuminate, indicating normal operation.
  2. Dispositivos de conexión: You can now power your 230V AC devices (up to 300W continuous, 600W peak) and charge USB devices.
  3. Función UPS: If the inverter is connected to both a 12V battery and a 230V AC mains supply, it will automatically switch to battery power in case of a mains power outage, providing an uninterrupted power supply to connected devices. When mains power is restored, it will switch back and recharge the battery.
  4. Apagado: Before disconnecting any devices or the inverter from the battery, switch the inverter's power switch to the OFF position.

7. Mantemento

  • Limpeza: Regularly clean the inverter's exterior with a dry, soft cloth. Ensure ventilation openings are free from dust and debris. Do not use liquid cleaners.
  • Comprobación de conexión: Periodically check all electrical connections (battery terminals, AC input/output) to ensure they are tight and free from corrosion.
  • Substitución de fusibles: If the inverter stops working due to an internal fault, check the fuses. Replace blown fuses only with fuses of the same type and rating (e.g., 30A). Refer to the manual or product labeling for specific fuse ratings.
  • Saúde da batería: Ensure the connected 12V battery is in good condition and adequately charged for optimal inverter performance.

8 Solución de problemas

ProblemaCausa posibleSolución
No power output / Inverter does not turn onLoose battery connection, discharged battery, blown fuse, inverter fault.Check battery connections. Recharge or replace battery. Check and replace fuses if necessary. If problem persists, contact support.
Red Fault LED illuminates / Inverter beepsOverload, short circuit, over-temperature, low battery voltage, batería alta voltage.Reduce connected load. Check for short circuits in connected devices. Ensure proper ventilation. Check battery voltage. Allow inverter to cool down.
Fan is noisy or constantly runningHigh internal temperature due to heavy load or insufficient ventilation.This is normal operation under load. Ensure adequate ventilation. Reduce load if fan runs excessively.
Devices not working correctly (e.g., mini-fridge beeping)Device power requirement exceeds inverter capacity, or device is sensitive to power fluctuations.Verify the power consumption of your device. Ensure it does not exceed 300W continuous. Some devices have high startup (surge) power requirements.

9. Especificacións

CaracterísticaEspecificación
MarcaCélula Verde
ModeloINV07 (Green Cell PRO)
Potencia Continua300 W
Surge Power (Peak)600 W
Vol. De entrada CCtage12 V
Saída CA Voltage230 V
Forma de onda de saídaPura Sine Wave
Frecuencia50 Hz
Función UPSYes, with Power Bypass
Saída USBSi
Dimensións (L x W x H)31 x 18 x 7.5 cm
Peso2 kg
Recommended Battery Capacity (for UPS)30 Amp-hours (minimum, larger for longer runtime)
Dispositivos compatiblesCar, Laptop, devices requiring pure sine wave power

10. Garantía e soporte

Green Cell products are designed for reliability and performance. For warranty information, please refer to the documentation provided with your purchase or visit the official Green Cell website. If you encounter any issues or require technical assistance, please contact Green Cell customer support through their official channels. Ensure you have your product model (INV07) and purchase details available when contacting support.

Documentos relacionados - INV07

Preview Manual de usuario do inversor de enerxía Green Cell
Comprehensive user manual for the Green Cell Power Inverter, detailing features, safety guidelines, connection instructions, operating status, and troubleshooting tips. Available in multiple languages including English, German, Polish, French, Spanish, and Italian.
Preview Manual do usuario do inversor de enerxía Green Cell: características, seguridade e funcionamento
Este manual do usuario ofrece información completa sobre o inversor de enerxía Green Cell, que abrangue as súas características, aplicacións, directrices de seguridade esenciais, procedementos de conexión e consellos para a resolución de problemas para unha conversión de enerxía fiable de CC a CA.
Preview Manual do inversor de enerxía Green Cell: convertidores de CC a CA de onda sinusoidal pura
Manual detallado para os inversores de potencia de onda sinusoidal pura Green Cell. Abarca as especificacións, as características, as directrices de seguridade e as instrucións de funcionamento para varios modelos, incluídos os convertidores de 12 V e 24 V CC a 230 V CA.
Preview Manual do usuario do inversor de corrente DELTA INV11-GC Green Cell de 2000 W
Manual de usuario do inversor de corrente DELTA INV11-GC Green Cell de 2000 W. Ofrece información esencial sobre a instalación, as precaucións de seguridade, as especificacións do produto e a correcta eliminación para unha conversión de corrente continua a corrente alterna fiable.
Preview Green Cell UPS Power Proof 750-2000 VA User Guide
Comprehensive user guide for the Green Cell UPS Power Proof series (750-2000 VA), covering specifications, installation, operation, safety, troubleshooting, and warranty information.
Preview SAI Green Cell PowerProof: Manual do usuario para modelos de 600 VA-2000 VA
Comprehensive user manual for the Green Cell PowerProof series of Uninterruptible Power Supplies (UPS), covering models from 600VA to 2000VA. Learn about safety, features, operation, and troubleshooting for reliable power protection.