1. Introdución
This manual provides essential instructions for the installation, operation, and maintenance of your FSP iFP600 Uninterruptible Power Supply (UPS). Please read this manual thoroughly before installing or operating the unit to ensure proper function and safety. The FSP iFP600 is designed to provide reliable power backup and surge protection for your electronic devices.

Imaxe 1.1: Fronte view of the FSP iFP600 UPS, showcasing its compact design and integrated LCD display.
2. Instrucións de seguridade
Please adhere to these important safety guidelines during installation, operation, and maintenance of the UPS:
- Non abra o SAI casing. Non hai pezas que o usuario poida reparar no interior. Encomende calquera mantemento a persoal de servizo cualificado.
- Do not connect appliances that could overload the UPS, such as laser printers, vacuum cleaners, or heaters.
- Ensure the UPS is connected to a grounded AC power outlet.
- Avoid placing the UPS in direct sunlight, near heat sources, or in environments with excessive dust, humidity, or corrosive substances.
- Position the UPS in a well-ventilated area to prevent overheating.
- In case of fire, use a dry chemical extinguisher. Water can be hazardous.
- The battery inside the UPS is not user-replaceable. Battery replacement should only be performed by qualified personnel.
3. Produto rematadoview
The FSP iFP600 UPS provides reliable power protection for your critical electronics. It features a compact design and an intuitive LCD display for monitoring status.
3.1 Contido do paquete
Ao abrir o paquete, comprobe que todos os compoñentes estean presentes e sen danos:
- FSP iFP600 UPS Unit
- Manual de usuario (este documento)
- Cable de alimentación
- Cable de comunicación USB

Image 3.1: The FSP iFP600 UPS shown alongside its retail packaging, illustrating the product's presentation.
3.2 Compoñentes do panel traseiro
Familiarize yourself with the connections on the rear panel of the UPS:

Imaxe 3.2: Detallada view of the FSP iFP600 UPS rear panel, highlighting connection points.
- Puntos de venda: Two SCHUKO type outlets for connecting protected equipment.
- Entrada AC: Connects the UPS to the main utility power.
- Fuse/Breaker: Overcurrent protection for the UPS.
- Comunicación USB: Port for connecting to a computer for monitoring and management.
- Combo RJ11/RJ45 Surge Protection: Provides surge protection for telephone/network lines.
4. Configuración e instalación
Follow these steps to set up your FSP iFP600 UPS:
- Desembalaxe: Retire con coidado o SAI da súa embalaxe. Inspeccione se houbo danos durante o envío.
- Colocación: Place the UPS on a flat, stable surface in a clean, cool, and well-ventilated area. Ensure adequate clearance around the unit for airflow.
- Carga inicial: Connect the UPS to a standard grounded AC outlet using the provided power cord. Allow the unit to charge for at least 4-6 hours before initial use to ensure optimal battery performance. The UPS will charge whether it is turned on or off.
- Equipo de conexión: Plug your computer, monitor, and other critical electronic devices into the UPS outlets (A). Do not connect surge suppressors or power strips to the UPS outlets.
- Comunicación USB (opcional): Connect the USB cable from the UPS USB port (D) to your computer's USB port to enable power management software features (software not included, typically downloaded from manufacturer's websitio).
- RJ11/RJ45 Protection (Optional): For surge protection of your telephone or network line, connect the incoming line to the 'IN' port of the Combo RJ11/RJ45 (E) and connect the 'OUT' port to your device.
5. Instrucións de funcionamento
5.1 Acendido/Apagado
- Para acender: Press and hold the power button on the front panel for approximately 2 seconds until you hear a beep and the LCD display illuminates.
- Para apagar: Press and hold the power button for approximately 2 seconds until you hear a beep and the LCD display turns off.
5.2 Información da pantalla LCD
The FSP iFP600 features an LCD display that provides real-time status information. The display is touch-sensitive for navigating information.

Image 5.1: The LCD display of the FSP iFP600 UPS, indicating voltage output and its touch-screen functionality.
The LCD display typically shows:
- Vol. De entradatage
- Vol. De saídatage
- Nivel de carga da batería
- Nivel de carga
- Operating Mode (e.g., AC mode, Battery mode)
- Warning/Fault Indicators
5.3 Battery Mode Operation
When the utility power fails or fluctuates outside acceptable limits, the UPS will automatically switch to battery mode. During battery mode, the UPS will provide power to connected equipment from its internal battery. An audible alarm will sound to indicate battery operation.
6. Mantemento
Proper maintenance ensures the longevity and reliability of your UPS.
- Limpeza: Use a soft, dry cloth to clean the exterior of the UPS. Do not use liquid or aerosol cleaners.
- Coidado da batería: To maximize battery life, ensure the UPS is connected to AC power and fully charged. If the UPS is stored for an extended period, recharge it every three months to prevent battery degradation.
- Substitución da batería: The internal battery (12V / 7Ah x1) is not user-serviceable. Battery replacement should only be performed by FSP-certified service personnel or a qualified technician. Incorrect battery replacement can pose a risk of explosion or injury.
- Almacenamento: Store the UPS in a cool, dry place with adequate ventilation. Ensure the battery is fully charged before storage.
7 Solución de problemas
Refer to the following table for common issues and their solutions. If the problem persists, contact FSP support.
| Síntoma | Alarma sonora | Causa posible | Solución |
|---|---|---|---|
| UPS operating on battery power | Emite pitidos cada 10 segundos | Utility power failure or fluctuation | Save work and shut down equipment if power outage is prolonged. UPS will return to AC mode when power is restored. |
| Aviso de batería baixa | Pita cada segundo | A carga da batería é críticamente baixa | Immediately save work and shut down connected equipment. |
| Condición de sobrecarga | Pitidos cada 0.5 segundo | Connected equipment exceeds UPS capacity | Disconnect non-essential equipment until the alarm stops. Ensure total load is within UPS capacity. |
| Fallo do UPS | Pito continuamente | Avería interna ou mal funcionamento | Turn off the UPS and disconnect it from the AC outlet. Contact FSP technical support. |

Image 7.1: Excerpt from the FSP iFP series specification table, detailing alarm indicators and their meanings.
8. Especificacións
Detailed technical specifications for the FSP iFP600 UPS:
| Característica | Especificación |
|---|---|
| Modelo | iFP 600 |
| Capacidade | 600 VA / 360 W |
| Vol. De entradatage | 110/120 Vac or 220/230/240 Vac |
| Vol. De entradatage Alcance | 81-145 Vac / 140-290 Vac |
| Intervalo de frecuencia de entrada | 60/50 Hz (detección automática) |
| Vol. De saídatage | 110/120 Vac or 220/230/240 Vac |
| Vol. ACtage Regulación (modo de batería) | ± 10 % |
| Output Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Tempo de transferencia | Típico de 2-6 ms |
| Forma de onda (modo Batt.) | Onda sinusoidal simulada |
| Tipo e número de batería | 12V / 7Ah x1 |
| Tempo de recarga típico | 4 horas ata o 90 % da súa capacidade |
| Indicadores | LCD Display (Touch panel with digital information) |
| Protección | Overload, Discharge, and Overcharge Protection |
| Peso do elemento | 9.24 libras (4.2 kg) |
| Dimensións do produto (LxWxH) | 11.81 x 3.98 x 5.59 polgadas |
| Cor | Negro |
| Material | Metal |
9. Garantía e soporte
FSP products are designed for reliability and performance. For warranty information, please refer to the warranty card included with your product or visit the official FSP website. For technical support, troubleshooting assistance, or service inquiries, please contact FSP customer service through their official channels.
Podes atopar máis información e recursos de apoio en FSP Store on Amazon.