AUTOOL LM150

AUTOOL Digital Refrigeration Manifold Gauge LM150 User Manual

Modelo: LM150

1. Produto rematadoview

The AUTOOL LM150 Digital Refrigeration Manifold Gauge is a professional instrument designed for precise measurement of pressure and temperature in refrigeration and air conditioning systems. It offers advanced features for comprehensive system analysis, including condensing pressure and temperature measurement, pressure maintaining, and leakage testing.

As funcións clave inclúen:

AUTOOL LM150 Function Display

Image: Display showing various functions and measurements of the LM150.

This image illustrates the main display of the AUTOOL LM150, highlighting its capability to show HP/LP line temperature and pressure, evaporation and condensing temperatures, and the selected refrigerant type. It visually confirms the device's multi-functional display for comprehensive system diagnostics.

2. Contido do paquete

Upon opening the package, please verify that all components are present and in good condition. The standard package for the AUTOOL LM150 includes:

AUTOOL LM150 Package Contents

Image: All items included in the AUTOOL LM150 package.

This image displays the complete set of items provided with the AUTOOL LM150, including the main unit, the protective carrying case, color-coded refrigerant hoses, and temperature clamp probes. It serves as a visual checklist for users to confirm all components are present.

3. Características e compoñentes do produto

The LM150 is designed with user convenience and accuracy in mind. Familiarize yourself with its key features and components:

AUTOOL LM150 3.5-inch Display

Image: Close-up of the LM150's 3.5-inch high-definition display.

This image focuses on the LM150's large, clear display, emphasizing its readability and the organized presentation of measurement data, crucial for quick and accurate readings in various working environments.

AUTOOL LM150 V-Shape Valve and Probes

Imaxe: Detallada view of the V-shape ball valve, high-quality material, and clip-on probes.

This image provides a closer look at the innovative V-shape ball valve design, highlighting its ease of control. It also showcases the robust construction materials and the practical clip-on temperature probes, illustrating the thoughtful engineering behind the device's components.

AUTOOL LM150 Built-in Refrigerant Database

Image: List of 93 built-in NIST standard refrigerants.

This image presents a comprehensive list of the 93 NIST standard refrigerants pre-programmed into the LM150's database. This feature allows the device to accurately calculate and display properties for a wide variety of common and specialized refrigerants, enhancing its versatility for professional use.

4. Configuración e conexións

Before operating the LM150, ensure proper setup and connection of all necessary components.

4.1 Disposición e controis do dispositivo

AUTOOL LM150 Labeled Diagram

Image: Labeled diagram of the AUTOOL LM150 with component descriptions.

This detailed diagram provides a clear visual guide to all external components and controls of the AUTOOL LM150. Each part is numbered and corresponds to a descriptive legend, aiding users in identifying ports, buttons, and features for correct operation and connection.

  1. Gancho: For hanging the unit during operation.
  2. Clamp-on temperature probe socket: Connect temperature probes here.
  3. Pantalla LCD: Shows all measurement data and settings.
  4. Run/Stop button: Initiates or pauses measurements.
  5. Botón de modo: Cambia ciclicamente por diferentes modos de medición.
  6. R- refrigerant type selection buttons: Decreases refrigerant type number.
  7. Botón de luz de fondo: Toggles display backlight.
  8. Refrigerant observation window: Visual check of refrigerant flow.
  9. Refrigerant inlet/vacuum pump inlet: Central port for vacuum pump or refrigerant charging.
  10. 1/4 inch low pressure inlet: Conéctase ao lado de baixa presión do sistema.
  11. Zero button: Resets pressure readings.
  12. Pressure unit switch button: Changes pressure units (kPa, MPa, bar, inHg, PSI).
  13. Botón de encendido: Acende/apaga o dispositivo.
  14. R+ refrigerant type selection buttons: Increases refrigerant type number.
  15. High pressure valve: Controls flow to the high-pressure side.
  16. Botón °C/°F: Toggles temperature units.
  17. Low pressure valve: Controls flow to the low-pressure side.
  18. Pressure release valve: Para liberar con seguridadeasinpresión g.
  19. 1/4 inch high pressure inlet: Conéctase ao lado de alta presión do sistema.

4.2 Configuración inicial

4.3 Connecting Hoses and Probes

5. Instrucións de funcionamento

The LM150 offers various modes for different diagnostic and service procedures.

5.1 Basic Pressure and Temperature Measurement

  1. Ensure the LM150 is powered on and correctly connected to the system.
  2. Open the high and low-pressure valves on the manifold to allow refrigerant flow to the gauge.
  3. The display will show real-time HP/LP pressure and corresponding saturation temperatures based on the selected refrigerant.
  4. The temperature probes will display the actual pipe temperatures.
AUTOOL LM150 Display Modes

Imaxe: Examples of different display screens for refrigerant filling, vacuum, and leakage detection.

This image illustrates the versatility of the LM150's display, showing how it presents data for various operations. It includes views for refrigerant filling (showing HP/LP pressure and temperatures), vacuum measurement (displaying vacuum percentage and pressure), and leakage detection (showing detection time, initial pressure, current pressure, and leakage pressure difference). This visual guide helps users understand the information presented during different diagnostic tasks.

5.2 Condensing Pressure and Temperature Measurement

This function measures the minimum pressure when refrigerant changes from gas to liquid and the maximum temperature during this phase change. Lower condensing pressure and temperature indicate higher refrigeration cycle efficiency.

  1. Connect the LM150 to the system as described in Section 4.3.
  2. Ensure the system is operating.
  3. The LM150 will automatically calculate and display the condensing pressure and temperature based on the high-pressure readings and selected refrigerant.

5.3 Pressure Maintaining and Leakage Test

This test determines if the refrigerant system has a leak by calculating the pressure difference over time.

  1. After evacuating or charging the system, close all manifold valves.
  2. Select the leakage test mode using the MODO botón.
  3. The device will record the initial pressure and monitor pressure changes over a set period.
  4. The display will show the detection time, initial pressure, current pressure, and the calculated leakage pressure difference.
  5. A significant pressure drop indicates a leak.

5.4 Refrigerant System Evacuation

  1. Connect the yellow hose to a vacuum pump and the system's service port (usually the low-pressure side).
  2. Open the low-pressure valve on the manifold.
  3. Iniciar a bomba de baleiro.
  4. Monitor the vacuum pressure and percentage on the LM150 display. Continue evacuation until the desired vacuum level is reached.
  5. Close the manifold valve and turn off the vacuum pump. Observe the vacuum reading for any rise, which would indicate a leak.

6. Mantemento

Un mantemento axeitado garante a lonxevidade e a precisión do seu AUTOOL LM150.

7 Solución de problemas

This section addresses common issues you might encounter with the LM150.

ProblemaCausa posibleSolución
O dispositivo non se acende.Pilas baixas ou gastadas; instalación incorrecta da pila.Substitúa as pilas por outras novas; asegúrese de manter a polaridade correcta.
Lecturas de presión inexactas.Hoses not properly connected; manifold valves not fully open/closed; unit not zeroed; damaged sensor.Check hose connections; ensure valves are in correct position; perform zero calibration; contact support if sensor damage is suspected.
Temperature probes not reading.Probes not securely plugged in; damaged probe cable/sensor.Ensure probes are fully inserted; inspect cable for damage; replace probe if faulty.
A pantalla está escura ou ilexible.Backlight off; low battery.Press the backlight button; replace batteries.
Cannot select desired refrigerant.Incorrect mode; button malfunction.Ensure you are in the correct mode for refrigerant selection; try cycling power.

8. Especificacións técnicas

Detailed specifications for the AUTOOL LM150 Digital Refrigeration Manifold Gauge:

AUTOOL LM150 Technical Parameters

Image: Table of technical parameters for the AUTOOL LM150.

This image provides a clear and concise table detailing the technical specifications of the AUTOOL LM150. It includes critical data such as pressure test range, resolution, accuracy, overload limit, vacuum test parameters, and temperature test range, resolution, and accuracy. This information is essential for understanding the device's capabilities and limitations.

ParámetroValor
Tipo de proba de presiónPresión manométrica
Unidades de proba de presiónkPa, MPa, bar, inHg, PSI
Rango de proba de presión0 kPa - 6000 kPa
Resolución da proba de presión1 Kpa
Precisión da proba de presión+/- 0.5 %(FS)+ 5dgt
Límite de sobrecarga de presión10000 Kpa (10 Mpa; 100 bar;)
Tipo de proba de baleirobaleiro relativo
Unidades de proba de baleirokPa; MPa; bar; polgadas de Hg; PSI
Rango de proba de baleiro-101 kPa ~ 0 kPa
Resolución da proba de baleiro1 Kpa
Unidades de proba de temperatura°C (Celsius), °F (Fahrenheit)
Rango de proba de temperatura-40 °C ~ 150 °C (-40 °F ~ 302 °F)
Resolución da proba de temperatura0.1°C (-40°C ~ 99.9°C), 1°C (100°C ~ 150°C); 0.1°F (-40°F ~ 99.9°F), 1°F (100°F ~ 302°F)
Precisión da proba de temperatura+/- 0.5 °C + 2dgt, +/- 0.9 °F + 2dgt
Dimensións do produto36.83 x 29.97 x 10.92 cm; 3.7 kg
Tamaño de visualización14.5 polgadas (diagonal)
MaterialMetal

9. Garantía e soporte

AUTOOL provides comprehensive support for its products.

AUTOOL Warranty and Support Information

Image: AUTOOL warranty and support information.

This image, while primarily showing technical parameters, also implicitly represents the brand's commitment to quality and support, which is often associated with detailed specifications and reliable products. For explicit warranty details, users should refer to the official warranty statement.

Documentos relacionados - LM150

Preview Manual do usuario do probador de presión dixital do colector AUTOOL LM150 - Ferramenta de refrixeración HVAC
Manual de usuario completo para o comprobador dixital de presión do colector AUTOOL LM150. Inclúe as especificacións do produto, as instrucións de funcionamento para o recheo de refrixerante, o baleiro e as probas de fugas, problemas comúns, glosario de termos, mantemento, garantía e política de devolución para profesionais de climatización e refrixeración.
Preview Manual do usuario do manómetro dixital AUTOOL LM120/LM120+
Este manual do usuario ofrece unha guía completa para o manómetro dixital de colector AUTOOL LM120/LM120+. Detalla as especificacións do produto, a estrutura e as instrucións de funcionamento para o recheo de refrixerante, o funcionamento ao baleiro e as probas de fugas a presión. O manual tamén inclúe problemas comúns, un glosario de termos, consellos de mantemento, información sobre a garantía e procedementos de devolución/cambio. Esencial para técnicos de climatización e profesionais da refrixeración.
Preview Manual do usuario do probador de presión dixital para colector AUTOOL LM150
Manual de usuario do probador dixital de presión do colector AUTOOL LM150, que proporciona instrucións detalladas, especificacións, directrices de seguridade e resolución de problemas para probas de sistemas de climatización e refrixeración.
Preview Manual do usuario do manómetro dixital AUTOOL Im 120
Manual de usuario completo para o manómetro dixital AUTOOL Im 120, que detalla as súas características, especificacións, instrucións de funcionamento para o recheo de refrixerante, probas de baleiro, detección de fugas, precaucións de seguridade, problemas comúns e un glosario de termos relevantes para os sistemas de refrixeración.
Preview Manual de usuario del manifold digital AUTOOL LM120+
Manual de usuario completo para o manómetro dixital AUTOOL LM120+, que detalla as súas características, especificacións, precaucións de seguridade, instrucións de funcionamento e consellos para a resolución de problemas en sistemas de refrixeración e climatización.
Preview Manual de usuario do kit de colector dixital intelixente AUTOOL LM160
Manual de usuario completo para o kit de colector dixital intelixente AUTOOL LM160, que abrangue o funcionamento, as especificacións técnicas, o mantemento e a seguridade para aplicacións de climatización.