Introdución
The Spectra S1 Plus Electric Breast Milk Pump is designed to provide comfortable and efficient breast milk expression, mimicking the natural suckling patterns of a baby. This portable and rechargeable pump is an essential tool for breastfeeding mothers, offering flexibility and convenience for pumping at home or on the go. All parts that come into contact with breast milk are BPA/DEHP free, ensuring safety for your baby.
Que está incluído
Your Spectra S1 Plus package includes the following components:

Figure 1: All components included with the Spectra S1 Plus breast pump.
- 1 x Spectra S1 Plus Pump Unit
- 2 x 24mm Breast Flanges
- 2 x 28mm Breast Flanges
- 2 x Tubo
- 2 x Válvulas de pico de pato
- 2 x Backflow Protectors
- 4 x Wide Neck Storage Bottles
- 1 x cargador de 12 V
- 1 x bolsa frigorífica
- 1 x Freezer Pack
- 1 x bolsa de tela
Instrucións de configuración
Follow these steps to set up your Spectra S1 Plus breast pump:
- Carga da bomba: Before first use, fully charge the pump using the provided 12V charger. The battery indicator on the display will show charging progress.
- Assemble Flanges and Bottles: Attach the duckbill valve to the bottom of the breast flange. Connect the backflow protector to the top of the breast flange. Screw a wide neck storage bottle onto the bottom of the breast flange assembly.
- Tubo de conexión: Insert one end of the tubing into the backflow protector. Insert the other end of the tubing into the port on the front of the pump unit. For double pumping, use both tubing ports. For single pumping, cap the unused port.
- Posicionamento: Ensure the breast flange is centered over your nipple for optimal suction and comfort.

Figure 2: Spectra S1 Plus pump and accessories ready for use.
Vídeo 1: Rematadoview of Spectra S1 Plus features and operation.
Instrucións de funcionamento
The Spectra S1 Plus offers various settings to customize your pumping experience:

Figure 3: Key features of the Spectra S1 Plus.
- Encendido/apagado: Press the power button to turn the pump on or off. The LCD screen will display the current settings.
- Modo de masaxe: This mode simulates the natural suckling of a baby to initiate milk flow. Press the massage mode button to activate it. You can adjust the cycle speed and vacuum strength in this mode.
- Modo de expresión: Once milk flow begins, switch to expression mode for deeper, slower suction. Adjust the cycle speed and vacuum strength to your comfort level. The pump features adjustable suction levels up to hospital strength.
- Temporizador automático: The pump includes an auto-timer on its easy-to-read display, allowing you to monitor your pumping session duration.
- Luz nocturna: A built-in night light provides soft illumination for nighttime pumping sessions without disturbing others. Press the light button to cycle through brightness settings.

Figure 4: Using the built-in night light for discreet pumping.

Figure 5: The night light feature allows for quiet, undisturbed pumping.
Guía de tamaño de bridas
Using the correct breast flange size is crucial for comfortable and effective milk expression. An improperly sized flange can lead to discomfort and reduced milk output.

Figure 6: Guide to measuring for correct flange size.
To determine your correct flange size, measure the diameter of your nipple (not the areola) at its base after a pumping session. Add 2-3mm to this measurement to find your ideal flange size. The Spectra S1 Plus includes both 24mm and 28mm flanges to help you find a comfortable fit.

Figure 7: Visual guide to proper breast flange fit.
Mantemento e Limpeza
Proper cleaning and maintenance are essential for hygiene and the longevity of your breast pump. All Spectra breast pump parts and accessories that come into contact with breast milk are BPA/DEHP free.

Figure 8: Spectra breast pump parts are BPA free.
- Despois de cada uso: Disassemble all parts that come into contact with breast milk (flanges, valves, backflow protectors, bottles). Wash them immediately in warm, soapy water. Rinse thoroughly with clean water.
- Esterilización: Sterilize parts regularly by boiling them for 5 minutes or using a steam sterilizer. Ensure all parts are completely dry before reassembly or storage.
- Tubo: The tubing should not come into contact with breast milk. If moisture or milk is observed in the tubing, replace it immediately. Do not wash or sterilize tubing.
- Unidade de bomba: Limpe a unidade da bomba principal cun pano limpo,amp cloth. Do not immerse the pump unit in water or other liquids.
Resolución de problemas
If you encounter any issues with your Spectra S1 Plus breast pump, please refer to the following common solutions:
- Sen succión ou succión débil:
- Check that all parts are correctly assembled and securely connected.
- Inspect duckbill valves and backflow protectors for tears or damage; replace if necessary.
- Ensure tubing is free of kinks and properly connected to both the pump and the backflow protector.
- Verify that the unused tubing port is securely capped for single pumping.
- A bomba non se acende:
- Ensure the pump is fully charged or connected to the power adapter.
- Check the power adapter and outlet for proper function.
- Molestias durante a extracción:
- Adjust the vacuum strength and cycle speed to a comfortable level.
- Re-evaluate your breast flange size using the sizing guide to ensure a proper fit.
Se os problemas persisten, póñase en contacto co servizo de atención ao cliente.
Especificacións
| Dimensións do produto | 18.25 x 12.38 x 12.75 polgadas |
| Peso | 8.6 libras |
| Número de modelo do artigo | MM011091-TG |
| Baterías | 1 pilas de iones de litio necesarias (incluídas) |
| Modo de operación | Eléctrico |
| Característica especial | Indolora |
| Fonte de enerxía | Alimentado por batería |
Garantía e Soporte