Prity FGW15

Prity FGW15 Wood-Burning Stove with Oven and Back Boiler

Manual de usuario

1. Introdución

This manual provides essential instructions for the safe and efficient installation, operation, and maintenance of your Prity FGW15 wood-burning stove with oven and back boiler. This appliance is designed to provide both room heating and hot water for central heating systems, while also offering a functional oven for cooking. Please read this manual thoroughly before using the appliance and retain it for future reference.

The Prity FGW15 stove complies with European standards EN 13240:2001 and EN 13299:2001, ensuring its quality and safety for domestic use.

2. Información de seguridade

Instalación profesional necesaria: This appliance requires professional installation by a qualified technician to ensure safe and correct operation, as well as compliance with local building codes and regulations. Improper installation can lead to fire hazards, carbon monoxide poisoning, and other serious risks.

2.1 Advertencias xerais de seguridade

2.2 Minimum Clearances to Combustible Materials

Maintain the following minimum distances from combustible materials to prevent fire hazards:

These distances are critical for safety. Consult your installer for specific requirements based on your installation.

2.3 Permissible Fuel

Usa só dry firewood as fuel. The wood moisture content should be 16 ± 4% according to EN 13240:2006, EN 13229:2006, EN 12815:2006 Annex B, Table B.1. Do not burn treated wood, plastics, coal, or any other materials not specified for wood-burning stoves, as this can damage the appliance, create hazardous emissions, and void your warranty.

3. Compoñentes do produto

The Prity FGW15 is a versatile appliance combining a wood-burning firebox, an oven, and a back boiler for central heating. Key components include:

Fronte view of Prity FGW15 wood-burning stove with oven and back boiler, showing the firebox, oven, and ash drawer.

Figura 3.1: Fronte view of the Prity FGW15 stove, highlighting the firebox, oven, and ash drawer.

Traseira view of Prity FGW15 wood-burning stove, showing the back boiler connections and flue outlet.

Figura 3.2: Traseira view of the Prity FGW15 stove, illustrating the cold and hot water connections for the back boiler and the flue pipe outlet.

4. Especificacións técnicas

Below are the detailed technical specifications for the Prity FGW15 wood-burning stove:

Prity FGW15 wood-burning stove dimensions: 93 cm height, 57 cm width, 53 cm depth.

Figure 4.1: Key dimensions of the Prity FGW15 stove.

CaracterísticaEspecificación
ModeloFGW15
MarcaPrity
Dimensións do produto (P x A x A)53 x 57 x 93 cm
Peso136 kg
MaterialFerro fundido
Nominal Room Heating Power5 kW
Nominal Water Heating Power15 kW
Total Nominal Heat Output19.8 kW
Capacidade da caldeira15 litros
Cold Water Inlet / Hot Water Outlet2.5 cm (1 polgadas)
Diámetro do tubo de combustión130 mm
Eficiencia76.5 %
Approximate Heating Surface Area114 m² (for room heating)
Dimensións da caixa de combustión (L x P x A)465 x 240 x 430 mm
Dimensións do forno (L x P x A)380 x 400 x 200 mm
Maximum Working Pressure (Water)1.25 bar
Temperatura dos gases de combustión192 °C
CO in Flue Gas1031.3 mg/Nm³ (0.0985 %)
Dust Content26.4 mg/Nm³
NOx Content102.7 mg/Nm³
CxHy Content43.8 mg/Nm³

5. Requisitos de instalación

Installation of the Prity FGW15 stove must be carried out by a certified professional in accordance with all national and local building and fire safety regulations. This includes proper chimney connection, flue pipe installation, and integration with your central heating system.

5.1 Chimney and Flue Pipe

5.2 Water Connections for Back Boiler

The back boiler requires connection to a closed or open central heating system. The cold water inlet and hot water outlet connections are 2.5 cm (1 inch). A qualified plumber must perform these connections, ensuring proper pressure relief valves, expansion tanks, and circulation pumps are installed according to system requirements and local codes.

5.3 Positioning and Clearances

Refer to Section 2.2 for minimum clearances to combustible materials. The stove must be placed on a non-combustible hearth extending beyond the appliance as required by local regulations.

6. Instrucións de funcionamento

Before operating, ensure all installation checks are complete and the central heating system (if connected) is filled and vented.

6.1 Starting the Fire

  1. Open both the front air supply damper and the smoke damper fully.
  2. Place a small amount of kindling and firelighters on the cast iron grate in the firebox.
  3. Light the kindling. Once it is burning well, add small pieces of dry firewood.
  4. Close the firebox door securely.
  5. Allow the fire to establish fully before adding larger logs.

6.2 Air Control and Flame Intensity

The stove is equipped with two manual dampers:

Adjust both dampers to achieve a steady, efficient burn. A bright, lively flame indicates good combustion. Excessive smoke or a dull, smoldering fire suggests insufficient air or poor draft.

6.3 Uso do forno

The oven utilizes heat from the firebox below. The oven temperature will vary depending on the intensity of the fire. Monitor the oven temperature gauge and adjust the fire's intensity as needed for cooking. Preheat the oven thoroughly before placing food inside.

7. Mantemento

Regular maintenance is crucial for the safe and efficient operation of your Prity FGW15 stove.

7.1 Eliminación de cinzas

Remove ash from the ash drawer regularly, ideally before each use or when the ash bed becomes thick. Allow the stove to cool completely before removing ash. Dispose of ash in a metal container with a tight-fitting lid, away from combustible materials.

7.2 Limpeza de cristais

Clean the ceramic glass on the firebox and oven doors as needed. Use a specialized stove glass cleaner or a damp cloth dipped in fine ash (when cold) to remove soot. Avoid abrasive cleaners or tools that could scratch the glass.

7.3 Flue Pipe and Chimney Cleaning

The flue pipe and chimney must be inspected and cleaned by a qualified chimney sweep at least once a year, or more frequently if heavy use or creosote buildup is observed. Blockages can lead to dangerous chimney fires and carbon monoxide accumulation.

7.4 Inspección xeral

Periodically check all seals, hinges, and dampers for wear or damage. Ensure water connections for the back boiler are free from leaks. Replace any worn parts promptly.

8 Solución de problemas

This section addresses common issues you might encounter with your Prity FGW15 stove.

ProblemaCausa posibleSolución
Smoke entering the roomBlocked chimney/flue, insufficient draft, door opened too quickly, wet fuel.Check chimney/flue for blockages. Ensure dampers are open. Use dry fuel. Open door slowly.
Baixa saída de calorInsufficient air supply, wet fuel, small fire, poor insulation.Aire libre dampers. Use dry, seasoned wood. Build a larger fire. Check room insulation.
O lume arde demasiado rápidoExcessive air supply, door not sealed properly.Aire pechado dampers partially. Check door seals and replace if necessary.
O vidro ennegrece rapidamenteWet fuel, insufficient air for combustion, low burning temperature.Use dry fuel. Increase air supply. Ensure fire burns hot enough.
Central heating not heating effectivelyLow fire intensity, air in system, pump malfunction, system blockage.Increase fire intensity. Bleed radiators. Check circulation pump. Consult a plumber.

If you encounter persistent problems that cannot be resolved using this guide, contact a qualified technician or your seller for assistance.

9. Conformidade e certificacións

The Prity FGW15 wood-burning stove is manufactured and tested to meet stringent European standards.

9.1 European Standards

This appliance complies with:

9.2 Etiqueta de eficiencia enerxética

The Prity FGW15 has an energy efficiency rating of A. This label provides information on the energy performance of the appliance.

Energy efficiency label for Prity FGW15 stove, showing an A rating and heat outputs.

Figure 9.1: Energy Efficiency Label for Prity FGW15.

9.3 Declaración de Prestación

A Declaration of Performance (DoP) is available, confirming the essential characteristics and performance of the product in accordance with Regulation (EU) No 305/2011.

Declaration of Performance document for Prity FGW15, detailing compliance and technical data.

Figure 9.2: English Declaration of Performance for Prity FGW15.

10. Garantía e soporte

For warranty information, please refer to the terms and conditions provided at the point of purchase or contact your seller directly. In case of technical issues, questions, or the need for spare parts, please contact the retailer from whom you purchased the Prity FGW15 stove. Ensure you have your purchase details and the product model number (FGW15) available when contacting support.

Documentos relacionados - FGW15

Preview Prity Fireplaces and Fireboxes: Installation and Operation Manual
Comprehensive guide for Prity fireplaces and fireboxes, covering technical specifications, installation procedures, operation instructions, maintenance, and warranty information. Ensure safe and efficient use of your Prity heating appliance.
Preview Prity Boilers: Technical Description, Installation, and Operation Manual
Comprehensive guide for Prity residential boilers, covering technical specifications, installation procedures, operation instructions, maintenance, and troubleshooting for solid fuel and pellet models.