Introdución
The ThermoPro TP30 Infrared Thermometer Gun is a versatile and accurate tool designed for non-contact surface temperature measurement. Utilizing advanced thermopile sensor technology, it provides rapid readings across a wide temperature range, making it ideal for various applications including cooking, HVAC diagnostics, automotive maintenance, and home repairs. This manual provides detailed instructions to help you get the most out of your device.
Características clave
- Highly Accurate: Accurate to ±1.5% with adjustable emissivity (0.1–1.0) for precise measurements on different surfaces.
- Ultra-Fast Response: Provides temperature readings in less than 500 milliseconds.
- Wide Temperature Range: Measures temperatures from -58°F to 1022°F (-50°C to 550°C).
- User-Friendly Display: Backlit LCD screen displays MAX/MIN/AVG temperatures and automatically shuts off after 90 seconds of inactivity.
- Laser Targeting: Features a 12:1 distance-to-spot ratio with a laser pointer for accurate targeting.
- Commonly-Found Batteries: Powered by 2 AAA batteries (included) with a low battery indicator.
Configuración
Instalación de baterías
Your ThermoPro TP30 requires two AAA batteries for operation. Follow these steps to install them:
- Localice a tapa do compartimento das pilas na asa do termómetro.
- Deslice ou solte a tapa con coidado para abrir o compartimento.
- Insira dúas pilas AAA, asegurándose de manter a polaridade correcta (+ e -) como se indica no interior do compartimento.
- Pecha a tapa do compartimento da batería de forma segura.

Encendido inicial
Once batteries are installed, simply pull the trigger to power on the device. The backlit LCD screen will illuminate, and the thermometer will be ready for use.
Instrucións de funcionamento
Tomando unha Medición
To measure the surface temperature of an object:
- Point the infrared lens towards the target surface.
- Pull and hold the trigger. The laser pointer will activate, indicating the measurement area.
- The temperature reading will instantly appear on the LCD screen.
- Solte o gatillo para manter a última temperatura medida na pantalla.

Understanding the Display Modes
The TP30 offers various display modes to provide comprehensive temperature data:
- MÁX .: Displays the maximum temperature recorded during a continuous scan.
- MIN: Displays the minimum temperature recorded during a continuous scan.
- AVG: Displays the average temperature recorded during a continuous scan.
Press the "MODE" button to cycle through these display options.

Temperature Units (°C/°F)
To switch between Celsius (°C) and Fahrenheit (°F), press the "°C/°F" button located on the device.
Emisividade axustable
Emissivity is the ability of a material to emit energy by radiation. Different materials have different emissivities. For the most accurate readings, adjust the emissivity setting (EMISS.) on your TP30 to match the surface you are measuring. The emissivity can be adjusted from 0.1 to 1.0.

Funcións adicionais
- Retroiluminación: Press the light bulb button to turn the display backlight on or off for improved visibility in different lighting conditions.
- Apagado automático: The thermometer will automatically turn off after 90 seconds of inactivity to conserve battery life.
- Indicador de batería baixa: An icon on the display will indicate when the batteries are low and need replacement.

Vídeo oficial do produto
Mantemento
Limpeza
To clean your ThermoPro TP30, simply wipe it with a clean, damp cloth. Do not immerse the device in water or use abrasive cleaners.
Almacenamento
Store the thermometer in a dry place away from extreme temperatures and direct sunlight. Remove batteries if the device will not be used for an extended period to prevent leakage.
Resolución de problemas
If you encounter issues with your ThermoPro TP30, refer to the following common solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| Sen pantalla ou pantalla escura | Pilas baixas ou gastadas; instalación incorrecta da pila. | Replace batteries with new AAA batteries; Ensure correct polarity. |
| Lecturas inexactas | Incorrect emissivity setting; Distance to target too far or too close; Lens is dirty. | Adjust emissivity to match material; Maintain optimal distance (12:1 D:S ratio); Clean the infrared lens. |
| O láser non funciona | Laser function is turned off. | Prema o botón do láser para activar o punteiro láser. |
| O dispositivo non se acende | Batteries are not installed or are dead. | Install or replace batteries. |
| NOTE: Not for Human Body Temperature | This device is designed for surface temperature measurement only. | Do not use for medical purposes or to measure human body temperature. |
Especificacións
| Especificación | Detalle |
|---|---|
| Rango de temperatura | -58 ° F ~ 1022 ° F (-50 ° C ~ 550 ° C) |
| Precisión | ± 1.5 % |
| Relación distancia-punto (D:S) | 12:1 |
| Tempo de resposta | < 500 ms |
| Emisividade | Adjustable 0.1 - 1.0 |
| Fonte de enerxía | 2 pilas AAA (incluídas) |
| Apagado automático | 90 segundos de inactividade |
| Tipo de visualización | LCD dixital retroiluminada |
| Material | Plástico |
| Peso do elemento | 4.5 onzas |
| Nome do modelo | TP30 |
Garantía e Soporte
ThermoPro products are designed for reliability and performance. For warranty information, technical support, or any questions regarding your TP30 Infrared Thermometer Gun, please visit the official ThermoPro websitio web ou póñase en contacto directamente co servizo de atención ao cliente. Garde o recibo de compra para reclamacións de garantía.