1. Introdución

Este manual ofrece instrucións completas para a instalación, o funcionamento e o mantemento do CQR Hold-up PA Double Push Panic Button. This device is designed to provide a reliable and immediate alert in emergency situations, integrating seamlessly with compatible alarm control panels. It features a double-press activation mechanism and a key-reset function to prevent accidental activation and ensure secure operation.

Lea este manual detidamente antes da instalación e o uso para garantir o seu correcto funcionamento e seguridade.

2. Información de seguridade

  • Seguridade eléctrica: Installation should only be performed by qualified personnel in accordance with all local and national electrical codes. Ensure power to the alarm control panel is disconnected before wiring.
  • Montaxe: Mount the device securely on a stable surface to prevent accidental dislodgement.
  • Ambiente: Do not expose the device to extreme temperatures, humidity, or direct water. It is designed for indoor use only.
  • Mantemento: Non intente abrir nin reparar o dispositivo vostede mesmo. Encargue calquera mantemento a persoal de servizo cualificado.
  • Proba: Regularly test the panic button's functionality in conjunction with your alarm system to ensure it is operating correctly.

3. Contido do paquete

Verifique que todos os elementos que se indican a continuación estean presentes no seu paquete:

  • CQR Hold-up PA Double Push Panic Button Unit
  • Key for Reset Function
  • Mounting Screws (may vary)
  • Este Manual de Usuario
CQR Hold-up PA Double Push Panic Button with key
Figure 3.1: The CQR Hold-up PA Double Push Panic Button, showing the two red push buttons, the keyhole for reset, and the included black reset key.
Close-up of the panic button reset key
Figura 3.2: Primeiro plano view of the metallic key used to reset the panic button after activation.
Product packaging for CQR Double Push PA
Figure 3.3: The product packaging, displaying the "DOUBLE PUSH PA" label and a barcode.

4. Configuración e instalación

The CQR Hold-up PA Double Push Panic Button is designed for surface mounting and integration with a compatible alarm control panel.

4.1. Lugar de montaxe

Choose a discreet yet easily accessible location for mounting, such as under a counter, desk, or near a point of sale. Ensure the surface is clean, dry, and structurally sound.

4.2. Wiring to Alarm Control Panel

  1. Desconectar a enerxía: Before beginning any wiring, ensure the alarm control panel is completely powered off and disconnected from its main power source and backup battery.
  2. Access Wiring Terminals: Abre o casing of the panic button (if applicable) to expose the wiring terminals. Refer to your alarm control panel's manual for specific zone input terminals for panic devices.
  3. Conecte cables: Connect the panic button's output wires to the designated panic zone input terminals on your alarm control panel. This device typically operates as a Normally Closed (NC) contact, opening upon activation. Consult the wiring diagram provided with your alarm control panel for correct polarity and connection points.
  4. Cableado seguro: Asegúrate de que todas as conexións dos cables estean seguras e debidamente illadas.
  5. Pechar Casing: Carefully close the panic button casing.

4.3. Montaxe da Unidade

  1. Marcar os buratos: Use the panic button unit as a template to mark the drilling locations for the mounting screws on your chosen surface.
  2. Perforar buratos piloto: Drill pilot holes if necessary, appropriate for the mounting screws.
  3. Dispositivo seguro: Align the panic button with the drilled holes and secure it firmly using the provided mounting screws. Do not overtighten.

4.4. Power On and Test

Once installation is complete, restore power to the alarm control panel. Perform a functional test of the panic button as described in the "Operating Instructions" section to ensure it triggers the alarm system correctly.

5. Instrucións de funcionamento

5.1. Activating the Panic Button

To activate the panic alarm, simultaneously press both red push buttons on the front of the unit. The double-press mechanism is designed to minimize accidental activations while ensuring quick response in an emergency.

Upon successful activation, the panic button will latch, and the alarm control panel will initiate the programmed panic response (e.g., siren activation, silent alarm, notification to monitoring station).

5.2. Resetting the Panic Button

After activation, the panic button will remain in a latched state until manually reset. To reset the device:

  1. Insert the provided key into the keyhole located on the top surface of the panic button.
  2. Turn the key clockwise (or counter-clockwise, depending on the specific mechanism) until the buttons release and return to their original position.
  3. Remove the key. The panic button is now reset and ready for re-activation.

Importante: Always keep the reset key in a secure and accessible location known only to authorized personnel.

6. Mantemento

The CQR Hold-up PA Double Push Panic Button requires minimal maintenance to ensure reliable operation.

  • Limpeza: Periodically wipe the exterior of the unit with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture.
  • Proba: It is recommended to test the panic button's functionality at least once a month to confirm its connection to the alarm system and proper activation/reset.
  • Inspección: Visually inspect the unit for any signs of damage, loose wiring, or tampering.

7 Solución de problemas

If you encounter issues with your CQR Hold-up PA Double Push Panic Button, refer to the following common problems and solutions:

ProblemaCausa posibleSolución
Panic button does not activate alarm.
  • Incorrect wiring to alarm panel.
  • Conexións de fíos soltas.
  • Alarm panel zone not properly configured.
  • Mal funcionamento do dispositivo.
  • Verify wiring against alarm panel manual.
  • Comprobe e asegure todas as conexións dos cables.
  • Consult alarm panel manual for zone programming.
  • Contact qualified service personnel if issue persists.
Panic button does not reset with key.
  • Key not fully inserted or turned correctly.
  • Obstrución ou dano do mecanismo interno.
  • Ensure key is fully inserted and turned firmly.
  • Do not force the key. If still stuck, contact service personnel.
Accidental activations.
  • Improper mounting location.
  • Physical obstruction.
  • Relocate the device to a less prone area.
  • Ensure no objects are pressing against the buttons.

If the problem persists after attempting these solutions, please contact your alarm system installer or the manufacturer's technical support.

8. Especificacións

CaracterísticaDetalle
ModeloHold-up PA Double Push
ASINB07WWCXZC9
MarcaCQR
FabricanteSecurity Components LTD
CorBranco
Tipo de activaciónDouble Press Latching
Reset MechanismReinicio de teclas
CompatibilidadeUniversal operation with Alarm control panel
Data de primeira dispoñibilidade22 de agosto de 2019

9. Garantía e soporte

Specific warranty information for the CQR Hold-up PA Double Push Panic Button is not provided within this manual. For details regarding warranty coverage, terms, and conditions, please refer to the documentation included with your purchase or contact the retailer or manufacturer directly.

For technical support, installation assistance, or troubleshooting beyond the scope of this manual, please contact your alarm system installer or the manufacturer, Security Components LTD, through their official channels.

You can visit the CQR Store on Amazon for more information: CQR Store

Documentos relacionados - B07WWCXZC9

Preview CQR Panic Buttons: Understanding and Specifications
Rematada integralview of CQR panic buttons, detailing types, features, security grades, and technical specifications for domestic and commercial applications.
Preview Botóns de pánico CQR: comprensión e especificacións do produto
Unha guía completa dos botóns de pánico CQR, que detalla a súa funcionalidade, tipos (mecánicos, electrónicos, de pulsación simple/dobre, confirmados), métodos de reinicio, opcións de instalación e acabados. Inclúe especificacións detalladas do produto e comparacións para as gamas PASP, PADP e EPA.
Preview CQR FP3 Manual Call Point & Security Devices | Technical Overview
Detalle técnicoview of CQR's FP3 Manual Call Point, featuring single and double pole configurations, EN54-11 certification, and other security products including Personal Attack Buttons, FP2 Call Points, Junction Boxes, and Empty Boxes.
Preview Dispositivo de retención da serie CQR PADP3: Instrucións de funcionamento e instalación
Guía completa para a instalación e o funcionamento do dispositivo de asalto da serie CQR PADP3, que abrangue a configuración, as especificacións e as características dos sistemas de seguridade.
Preview CQR PADP2 Grade 1: Double Push Hold Up Device | Security Solutions
Explore the CQR PADP2 Grade 1 Double Push Hold Up Device. This brochure details its features, technical specifications, product codes, and compliance with PD6662:2010 for reliable security applications.
Preview CQR Security Intruder Detection Systems Product Catalog
Comprehensive product catalog from CQR Security detailing intruder detection systems, including a wide range of cables, magnetic contacts, sounders, shock sensors, hold-up devices, call points, power supplies, junction boxes, exit buttons, and 12V fire detectors for security applications.