Introdución
The Fluke Ti401 Pro Thermal Imager is a high-resolution instrument designed for fast and accurate thermal inspections. With its 640 x 480 resolution, it provides the image quality necessary to conduct inspections efficiently. This manual provides essential information for the safe and effective use, maintenance, and troubleshooting of your Fluke Ti401 Pro Thermal Imager.
Información de seguridade
Always follow basic safety precautions when using this product to reduce the risk of injury or damage to the product or other equipment. Read all instructions before use.
- Do not operate the imager if it is damaged or operating abnormally.
- Use only Fluke-approved accessories and replacement parts.
- Keep the imager dry and clean. Do not expose it to extreme temperatures or humidity.
- Refer to the Fluke website for complete safety specifications and warnings.
O que hai na caixa
Comprobe que todos os artigos estean presentes e en bo estado ao desembalar:
- Cámara IR
- fonte de alimentación de CA
- 2 battery packs and charger
- Tarxeta SD
- Correa
Configuración
Instalación e carga da batería
The Fluke Ti401 Pro uses 3 Lithium Ion batteries. Ensure batteries are fully charged before first use.
- Insert the charged battery pack into the battery compartment at the base of the imager handle until it clicks into place.
- To charge, connect the AC power supply to the battery charger and plug it into a power outlet. Insert the battery pack into the charger.
- A full charge typically takes several hours. Refer to the charger's indicator lights for charging status.
Encendido inicial
Press and hold the power button located on the imager to turn it on. The display will illuminate, showing the Fluke logo before entering the main operating screen.

The Fluke Ti401 Pro Thermal Imager displaying the Fluke Connect mobile app pairing screen, indicating its connectivity features.
Connecting to Fluke Connect
The Fluke Ti401 Pro can connect to Fluke Connect for data management and remote viewing. Follow the on-screen prompts to pair your imager with the Fluke Connect mobile app on a compatible device.
Instrucións de funcionamento
Operación básica
To power on the imager, press the power button. To power off, press and hold the power button until the shutdown prompt appears, then confirm.

The Fluke Ti401 Pro Thermal Imager displaying a detailed thermal image, highlighting its clear screen and ergonomic design.
Laser Sharp Auto Focus
The imager features Laser Sharp Auto Focus for precise and rapid focusing. Point the imager at your target and press the focus button to achieve a sharp image in seconds. This ensures accurate temperature measurements.
Interchangeable Smart Lenses
The Ti401 Pro supports interchangeable Smart Lenses, allowing you to capture images near and far without the need for calibration. To change a lens, carefully twist and remove the current lens, then align and attach the new lens until it locks into place.
IR-Fusion Technology
Utilize Fluke's patented IR-Fusion technology to adjust the level of infrared and visible light in your images. This feature allows you to blend thermal and visual images to better identify problem areas and provide context to your thermal readings. Access IR-Fusion settings through the on-screen menu.

A technician using the Fluke Ti401 Pro Thermal Imager to inspect industrial piping, demonstrating its application in real-world scenarios.

A technician using the Fluke Ti401 Pro Thermal Imager to inspect industrial machinery, showcasing its utility for diagnostics.
Mantemento
Cleaning the Imager
To clean the imager, use a soft, damp cloth. Do not use abrasive cleaners, solvents, or harsh chemicals. For the lens, use a lens cleaning cloth and solution specifically designed for optical surfaces.
Coidado da batería
To maximize battery life, store batteries in a cool, dry place. If the imager will not be used for an extended period, remove the batteries. Recharge batteries regularly, even if not in use, to maintain their capacity.
Almacenamento
Store the imager in its protective case when not in use. Avoid storing it in areas with extreme temperatures, high humidity, or direct sunlight.
Resolución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| Imager does not power on. | Batería baixa ou esgotada. | Charge the battery or replace with a fully charged one. |
| A imaxe está borrosa ou desenfocada. | Imager not focused correctly. | Use Laser Sharp Auto Focus or manually adjust focus. |
| A pantalla está en branco ou conxelada. | Software error or system crash. | Perform a soft reset by holding the power button for 10 seconds. If issue persists, remove and reinsert battery. |
| Cannot connect to Fluke Connect. | Bluetooth/Wi-Fi off or pairing issue. | Ensure wireless features are enabled on both devices. Re-attempt pairing process. |
Especificacións
- Número de modelo: TI401-PRO 60HZ
- Dimensións do produto: 6.5 x 4.8 x 10.9 polgadas
- Peso do artigo: 16 onzas
- Baterías: 3 baterías de iones de litio (incluídas)
- Fonte de enerxía: Alimentado por batería
- Cor: Gray, yellow, Black
- Fabricante: Fluke
- Data de primeira dispoñibilidade: 17 de abril de 2019
Garantía e Soporte
Fluke products are built to last and are backed by a limited warranty. For specific warranty terms and conditions, please refer to the documentation included with your product or visit the official Fluke websitio.
For technical support, service, or to register your product, please visit the Tenda Fluke en Amazon or the main Fluke support websitio.