OJ Electronics UDG4-4999-B

OJ Microline UDG4-4999 Thermostat User Manual

Programmable Thermostat for Radiant Floor Heating Systems

1. Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of your OJ Microline UDG4-4999 Touch Screen Programmable Thermostat. Designed for electric radiant floor heating systems, this thermostat features dual voltage (120V/240V) and dual sensing (air/floor) capabilities, along with a built-in Class A GFCI for enhanced safety. Please read this manual thoroughly before installation and use to ensure proper function and safety.

OJ Microline UDG4-4999 Thermostat front view

Figura 1: Fronte view of the OJ Microline UDG4-4999 Thermostat, displaying its intuitive touch screen interface.

2. Información de seguridade

AVISO: Risk of electric shock. Installation must be performed by a qualified electrician in accordance with local electrical codes. Disconnect power at the circuit breaker before installing or servicing the thermostat.

3. Configuración e instalación

The UDG4-4999 thermostat is designed for easy installation in a standard electrical box. It supports both 120V and 240V systems and includes a floor sensor for precise temperature control.

3.1 Desembalaxe e compoñentes

Carefully remove the thermostat and its components from the packaging. The package should include:

3.2 Instrucións de cableado

Follow the wiring diagram below for correct installation. Ensure all connections are secure and comply with local electrical codes. The thermostat requires a dedicated circuit.

Wiring diagram for OJ Microline UDG4-4999 Thermostat

Figure 2: Technical specifications and wiring diagram for the UDG4-4999 Thermostat. Note the connections for Neutral, Hot from power source, and House Ground.

  1. Desconecte a alimentación no disyuntor principal.
  2. Connect the power supply wires (Line/Load) to the appropriate terminals on the thermostat as indicated in the wiring diagram.
  3. Connect the floor heating cable wires to the designated heating load terminals.
  4. Connect the floor sensor wires to the sensor terminals. Ensure the sensor is properly placed in the floor according to heating system manufacturer guidelines.
  5. Fixe o termostato á caixa eléctrica empregando os parafusos proporcionados.
  6. Restablecer a enerxía no interruptor automático.

4. Instrucións de funcionamento

The UDG4-4999 thermostat features an intuitive 3.5" responsive touch color screen for easy operation and programming.

4.1 Initial Setup and Install Wizard

Upon first power-up, the thermostat will guide you through an Install Wizard to set basic parameters such as date, time, temperature units, and floor type.

4.2 Basic Temperature Adjustment

From the main screen, you can easily adjust the setpoint temperature using the up and down arrows. The thermostat will temporarily override any active program until the next scheduled event.

Hand adjusting temperature on thermostat screen

Figure 3: A hand interacting with the thermostat screen to adjust the temperature setpoint.

4.3 Programación do termostato

The thermostat offers a 7-day programmable schedule with multiple events per day to optimize comfort and energy savings. Access the programming menu via the main screen's menu button.

4.4 Funcións avanzadas

5. Mantemento

The OJ Microline UDG4-4999 thermostat requires minimal maintenance.

6 Solución de problemas

Se tes problemas co teu termostato, consulta os seguintes problemas e solucións comúns:

ProblemaCausa posibleSolución
A pantalla do termostato está en branco.No power, tripped circuit breaker, or loose wiring.Check circuit breaker. Ensure wiring connections are secure. Contact a qualified electrician if problem persists.
O sistema de calefacción non se acende.GFCI tripped, thermostat in OFF mode, or wiring issue.Press the GFCI 'Reset' button. Check thermostat mode. Verify wiring.
Temperatura imprecisa.Floor sensor issue or improper placement.Ensure floor sensor is correctly installed and not damaged.
Cannot turn the thermostat completely OFF for summer.Thermostat may not have a dedicated 'OFF' button for the heating function, or it's in a continuous program mode.Set the thermostat to Vacation Mode with a very low setpoint, or use the 'OFF' setting if available in the menu. For complete power disconnection, turn off the dedicated circuit breaker.

7. Especificacións

CaracterísticaDetalle
Número de modeloUDG4-4999-B
Voltage120 V/240 V CA
Carga máxima15 Amps (1800W@120V, 3600W@240V)
GFCIClass A (5mA trip level)
Tipo de control de temperaturaCalefacción por chan
SensaciónDual Sensing (Air & Floor)
Floor Limit Range+41 a +104 °F (+5 a +40 °C)
Rango de temperatura ambiente+32 a +104 °F (0 a +40 °C)
Tipo de visualizaciónPantalla táctil de 3.5 polgadas
Tecnoloxía de conectividadeCon cable
Tipo de montaxeSoporte de parede
CertificaciónsC-UL-us Listed, Certified for Wet Room installations
DimensiónsAprox. 6 x 3.5 x 2.6 polgadas
Peso do elemento12.8 onzas

8. Garantía e soporte

8.1 Limited Factory Warranty

The OJ Microline UDG4-4999 Thermostat comes with a 3-Year limited factory WarrantyEsta garantía cobre defectos de materiais e fabricación en condicións normais de uso. Conserve o comprobante de compra para reclamacións de garantía.

8.2 Atención ao cliente

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact OJ Electronics customer support. Refer to the official OJ Electronics websitio para obter a información de contacto máis actualizada.

Documentos relacionados - UDG4-4999-B

Preview Termostato OJ Microline UTN4-4999 para calefacción por chan radiante eléctrica | OJ Electronics
Explora o OJ Microline UTN4-4999, un termostato elegante e intuitivo para calefacción por chan radiante eléctrica. As súas características inclúen rexistro de enerxía, protección do chan, GFCI e especificacións técnicas detalladas. Ideal para instalacións residenciais.
Preview OJ Electronics UDG/UDG/UTN/USG Thermostat User Manual & Installation Guide
User and installation guide for OJ Electronics UDG, UDG, UTN, USG thermostats. Covers installation, programming, operation, GFCI safety, and troubleshooting for electric underfloor heating systems.
Preview UDG4 Touch Thermostat Interactive User Manual
Explore the features and operation of the OJ Electronics UDG4 Touch Thermostat with this interactive user manual. Learn to program schedules, manage settings, and optimize your home's heating for comfort and energy efficiency.
Preview OJ Electronics UTN5 Touch Thermostat Quick Start and Mounting Guide
This guide provides essential information for installing and operating the OJ Electronics UTN5 Touch Thermostat. It covers setup procedures, navigation, wiring, sensor connections, GFCI testing, and technical specifications for underfloor heating systems.
Preview OJ Electronics Type UDG, UCG, UTN, USG Thermostat Installation and User Manual
Comprehensive guide for OJ Electronics UDG, UCG, UTN, and USG series thermostats, covering installation, programming, operation, GFCI testing, and troubleshooting. Includes technical specifications and safety information.
Preview OJ Electronics UTN4/ATN4 Thermostat Quick Start Guide - Underfloor Heating Control
Concise guide for installing and operating the OJ Electronics UTN4/ATN4 thermostat. Learn about temperature control, time setting, floor type selection, and GFCI/EGFPD testing for underfloor heating systems.