1. Introdución
Thank you for choosing the Wellue B02 Automatic Upper Arm Blood Pressure Monitor. This device is designed for accurate and convenient measurement of your blood pressure and heart rate at home. It features a large, easy-to-read 3-color backlit LCD display, dual-user memory, and an adjustable cuff for comfortable use. Please read this manual thoroughly before using the device to ensure correct operation and to obtain the most accurate results.

Image 1.1: The Wellue B02 Blood Pressure Monitor with its accessories, including the cuff, AAA batteries, and USB cable.
2. Contido do paquete
Ao abrir o paquete, comprobe que todos os elementos enumerados a continuación estean presentes e non estean danados:
- 1 x Wellue B02 Blood Pressure Monitor
- 1 x Upper Arm Cuff (22-40 cm)
- 1 x cable USB
- 4 x pilas AAA
- 1 x Manual de usuario (este documento)
- 1 x bolsa de almacenamento

Image 2.1: A visual representation of all items included in the Wellue B02 Blood Pressure Monitor package.
3. Produto rematadoview
The Wellue B02 monitor is designed for ease of use, featuring a clear display and intuitive controls.
3.1 Compoñentes do dispositivo
- Pantalla LCD: Shows blood pressure readings (SYS, DIA), pulse rate, date, time, and user indicator. Features a 3-color backlight for easy interpretation.
- Botón START/STOP: Powers the device on/off and initiates/stops a measurement.
- Botón SET: Used to adjust settings such as date, time, and user selection.
- Botón MEM: Accede aos rexistros de medición almacenados.
- Porto do manguito: Conecta o tubo de aire do manguito ao monitor.
- Porto de alimentación USB: For optional power supply via USB cable.
- Compartimento de batería: Contén 4 pilas AAA.

Imaxe 3.1: Unha sobreview of the Wellue B02 monitor highlighting its key features such as the LCD display, dual-user mode, and power options.
4. Configuración
4.1 Fonte de alimentación
The monitor can be powered by either AAA batteries or a USB cable.
- Instalación da batería: Abra a tapa do compartimento das pilas na parte traseira do dispositivo. Insira 4 pilas AAA, asegurándose de manter a polaridade correcta (+/-). Peche a tapa con seguridade.
- Potencia USB: Connect the provided USB cable to the USB port on the side of the monitor and to a compatible USB power source (e.g., wall adapter, computer USB port).
4.2 Colocación do manguito
Insert the air tube connector from the cuff firmly into the air jack on the left side of the monitor.
4.3 Axuste da data e hora
Cando o dispositivo estea apagado, manteña premido o botón SET button for 3 seconds to enter setting mode. Use the MEM button to adjust values and the SET button to confirm and move to the next setting (Year, Month, Day, Hour, Minute). Press INICIAR/PARAR para saír do modo de configuración.

Image 4.1: The Wellue B02 monitor illustrating its dual power supply options: battery power and USB cable connection.
5. Instrucións de funcionamento
5.1 Antes da medición
- Evite comer, beber alcohol, fumar, facer exercicio e bañarse durante 30 minutos antes da medición.
- Descanse polo menos 5 minutos antes de tomar unha medición.
- Sente nunha posición cómoda coas costas apoiadas e os pés planos no chan.
- Place your arm on a flat surface so the cuff is at heart level.
5.2 Aplicación do manguito
The adjustable cuff (22-40 cm) is designed to fit most adult upper arms.
- Slide your left arm through the cuff loop. The air tube should run down the inside of your arm.
- Position the cuff so the bottom edge is approximately 2-3 cm above your elbow joint.
- Wrap the cuff snugly around your upper arm. Ensure it is not too tight or too loose.
- The artery mark on the cuff should be aligned with your brachial artery (inner arm).
5.3 Tomar unha medida
- Preme o INICIAR/PARAR botón. O manguito inflarase automaticamente.
- Permanecer quieto e en silencio durante a medición.
- Once the measurement is complete, the cuff will deflate, and your systolic pressure (SYS), diastolic pressure (DIA), and pulse rate will be displayed on the LCD screen.
- The result will be automatically stored in the selected user's memory.
5.4 Modo de usuario dual
The device supports two users (User A and User B) with 120 memory sets each.
- To switch between User A and User B, press the SET button briefly when the device is off. The user icon will change.
- Measurements taken will be stored under the currently selected user profile.

Image 5.1: The Wellue B02 monitor demonstrating its dual-user capability, allowing two individuals to track their blood pressure readings separately.
5.5 Función de memoria
Para review past measurements:
- When the device is off, press the MEM button. The screen will display the average of the last three readings for the current user.
- Preme MEM again to scroll through individual past readings, from most recent to oldest.
- Each record includes SYS, DIA, Pulse, date, and time.
6. Comprender os resultados
The Wellue B02 monitor features a 3-color backlit LCD display to help you quickly interpret your blood pressure readings according to World Health Organization (WHO) guidelines.
- Retroiluminación verde: Indicates normal blood pressure.
- Retroiluminación laranxa: Indicates mild hypertension.
- Retroiluminación vermella: Indicates severe hypertension.
The monitor also includes an irregular heartbeat indicator and a movement error indicator to ensure measurement reliability.

Image 6.1: Explanation of the Wellue B02's 3-color backlit display, showing how green, orange, and red indicate different blood pressure ranges.

Image 6.2: The Wellue B02 monitor displaying its arrhythmia checking capability, which alerts users to irregular heartbeats.
7. Mantemento e coidados
- Clean the monitor and cuff with a soft, dry cloth. Do not use abrasive cleaners or immerse the device in water.
- Garde o dispositivo na bolsa de almacenamento proporcionada nun lugar fresco e seco, lonxe da luz solar directa e de temperaturas extremas.
- Retire as pilas se non vai usar o dispositivo durante un período prolongado para evitar fugas.
- Do not attempt to disassemble or repair the monitor yourself. Contact customer support for assistance.
8 Solución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| O dispositivo non se acende. | Batteries are depleted or incorrectly inserted; USB cable not connected. | Substitúa as pilas por unhas novas, asegurándose de que a polaridade sexa correcta. Comprobe a conexión do cable USB. |
| Cuff does not inflate or inflates incorrectly. | Cuff not properly connected; air leakage; cuff damaged. | Ensure cuff air tube is securely inserted into the monitor. Check cuff for any visible damage or leaks. |
| Lecturas inexactas. | Incorrect cuff placement; movement during measurement; not resting before measurement. | Refer to section 5.2 for correct cuff placement. Remain still and silent. Rest for 5 minutes before measuring. |
| Mensaxe de erro na pantalla. | Measurement error (e.g., excessive movement, irregular heartbeat). | Repeat the measurement after resting for a few minutes, ensuring proper technique. If errors persist, consult a healthcare professional. |
9. Especificacións
- Modelo: B02
- Método de medición: Oscilométrico
- Rango de medición: Presión arterial: 0-299 mmHg; Pulso: 40-199 latidos/minuto
- Precisión: Blood Pressure: ±3 mmHg (±0.4 kPa); Pulse: ±5% of reading
- Tamaño do manguito: 22-40 cm (Upper Arm)
- Memoria: 2 users x 120 sets with date and time
- Visualización: Large 3-color backlit LCD
- Fonte de enerxía: 4 x AAA batteries (included) or USB DC 5V
- Dimensións: Aproximadamente 16.6 x 12 x 7.8 cm
- Peso: Aproximadamente 252 gramos (sen pilas)
- Condicións de funcionamento: Temperature: 5°C to 40°C; Humidity: 15% to 85% RH
- Condicións de almacenamento: Temperature: -20°C to 55°C; Humidity: 10% to 93% RH
10. Información importante de seguridade
ADVERTENCIAS:
- This device is intended for adult home use only. Consult your physician for interpretation of blood pressure readings. Self-diagnosis and treatment based on measurement results can be dangerous.
- Do not use this device on infants, children, or individuals unable to express consent.
- Do not use this device if you have a serious arrhythmia.
- Product packaging may contain information different from what is shown online. Always read labels, warnings, and instructions provided with the product before use.
- Manter fóra do alcance dos nenos. As pezas pequenas poden supoñer un perigo de asfixia.
11. Garantía e soporte
The Wellue B02 Automatic Upper Arm Blood Pressure Monitor comes with a garantía dun ano desde a data de compra.
For technical assistance, troubleshooting, or warranty claims, please contact our customer support. We offer 24-hour technical service para garantir a súa satisfacción.
Conserve o recibo de compra como comprobante de compra para efectos de garantía.