1. Introdución
This manual provides essential information for the safe and efficient operation of your Green Cell UPS 1000VA 600W. Please read this manual thoroughly before installation and use, and retain it for future reference. The Uninterruptible Power Supply (UPS) is designed to protect your electronic devices from power outages, surges, and fluctuations, ensuring continuous operation and safe shutdown.
2. Instrucións de seguridade
- Non abra o SAI casing. Non hai pezas que o usuario poida reparar no interior. Encomende calquera mantemento a persoal de servizo cualificado.
- Non expoña o SAI á choiva, á humidade ou a un exceso de humidade.
- Asegúrese de que haxa unha ventilación axeitada arredor do SAI. Non bloquee as aberturas de ventilación.
- Coloque o SAI sobre unha superficie estable e plana.
- Conecte o UPS só a unha toma de corrente conectada a terra.
- Do not connect non-computer related equipment such as medical devices, life support equipment, or household appliances to the UPS.
- In case of fire, use a dry chemical extinguisher. Water can cause electrical shock.
3. Contido do paquete
- Green Cell UPS 1000VA 600W (Model UPS03)
- Cable de alimentación (C13)
- cable USB
- Manual de instrucións
4. Configuración
4.1 Desembalaxe e inspección
Desembala coidadosamente o SAI e inspecciónao para ver se hai algún dano durante o envío. Se atopa algún dano, non faga funcionar a unidade e póñase en contacto co seu distribuidor.
4.2 Colocación
Place the UPS in a clean, dry, and well-ventilated area, away from direct sunlight, heat sources, and excessive dust. Ensure there is adequate space around the unit for proper airflow. The UPS is designed for indoor use only.
4.3 Conexión á enerxía
- Connect the provided power cable to the UPS input port and then to a grounded 230V wall outlet.
- Allow the UPS to charge for approximately 8 hours before initial use to ensure optimal battery performance. The unit will charge whether it is turned on or off.
4.4 Conexión de dispositivos
The UPS features 2 Schuko outlets and 2 IEC outlets for connecting your equipment. Connect your computer, monitor, and other critical devices to these outlets. These outlets provide battery backup and surge protection.

Figure 1: Rear panel of the Green Cell UPS, illustrating the input power connection, USB and RJ45 ports, and the 2 Schuko and 2 IEC output sockets for connecting protected devices.
4.5 USB/RJ45 Connections
Connect the USB cable from the UPS to your computer to enable monitoring and management via the Green Cell application. The RJ45 ports provide surge protection for network connections (IN/OUT).
5. Funcionamento do SAI
5.1 Acendido/Apagado
- To turn on the UPS, press and hold the power button on the front panel for a few seconds until the LCD display illuminates.
- To turn off the UPS, press and hold the power button again until the display turns off.
5.2 Pantalla LCD
The LCD display provides real-time information about the UPS status, including input/output voltage, battery charge level, load percentage, and operational mode (e.g., AC mode, battery mode). Refer to the display for quick status checks.

Figure 2: The Green Cell UPS in an office environment, showcasing its front panel with the illuminated LCD display providing operational status.
5.3 Automático Voltage Regulación (AVR)
The UPS features Automatic Voltage Regulation (AVR) to stabilize incoming utility power. This function automatically corrects minor voltage fluctuations (sags and surges) without switching to battery power, extending battery life.
5.4 Battery Mode Operation
No caso dunha alimentación outage, the UPS will automatically switch to battery power within 2-6 milliseconds. The connected devices will continue to receive power from the UPS batteries. The backup time can be up to 30 minutes, depending on the connected load. The UPS will emit an audible alarm during battery mode operation.

Figure 3: The Green Cell UPS providing power protection for entertainment systems, demonstrating its versatility in various home setups.
5.5 Xestión de software
Install the Green Cell application on your computer (connected via USB) to access advanced UPS management options. This software allows you to:
- Monitor UPS status and power parameters in real-time.
- Receive notifications about power events.
- Schedule automatic shutdowns for connected devices during extended power outages.
- Perform battery self-tests.
6. Mantemento
6.1 Coidado coa batería
The UPS uses two 12V/7Ah AGM lead-acid batteries. To maximize battery lifespan:
- Ensure the UPS is kept in a cool, dry environment.
- Evitar descargas profundas frecuentes.
- Perform a battery self-test via the software periodically (e.g., every 3-6 months).
- Batteries typically have a lifespan of 2-5 years, depending on usage and environmental conditions. If the backup time significantly decreases, battery replacement may be necessary. Battery replacement should be performed by qualified personnel.
6.2 Limpeza
Clean the exterior of the UPS with a soft, dry cloth. Do not use liquid or aerosol cleaners. Ensure ventilation openings are free from dust and debris.
7 Solución de problemas
This section addresses common issues you might encounter with your UPS. For problems not listed here, please contact technical support.
| Problema | Causa posible | Solución |
|---|---|---|
| O SAI non se acende | No input power; Battery discharged; Power button not held long enough. | Check power cable connection and wall outlet. Allow UPS to charge for 8 hours. Press and hold power button for 3-5 seconds. |
| UPS beeps continuously in AC mode | Sobrecarga; Fallo interno. | Reduce connected load. If problem persists, contact support. |
| Tempo de copia de seguridade curto | Batería non completamente cargada; batería a piques de chegar ao final da súa vida útil; sobrecarga. | Allow UPS to charge fully. Reduce connected load. Consider battery replacement if batteries are old. |
| High-pitched sound (coil whine) | Normal operational characteristic for some electronic components. | This is often a characteristic of the unit and not a fault. Ensure proper ventilation. If the sound is excessively loud or new, contact support. |
| Plastic/chemical smell | New unit off-gassing; Overheating. | Ensure good ventilation. The smell should dissipate over a few days. If it persists or is accompanied by smoke, immediately disconnect the unit and contact support. |
| Software not connecting via USB | Incorrect driver; USB cable issue; Software not installed correctly. | Ensure correct drivers are installed. Try a different USB port or cable. Reinstall the Green Cell application. |
8. Especificacións
| Característica | Especificación |
|---|---|
| Modelo | UPS 03 |
| Capacidade | 1000 VA (600 W) |
| Vol. De entradatage | 230 V |
| Vol. De saídatage | 230 V |
| Forma de onda de saída | Onda sinusoidal modificada |
| Tempo de transferencia | 2-6 milisegundos |
| Puntos de venda | 2x Schuko, 2x IEC |
| Tipo de batería | 2x 12V/7Ah AGM Lead-Acid |
| Tempo de recarga | De 8 horas a 90% de capacidade |
| Interfaces | USB, RJ45 (surge protection) |
| Dimensións (L x W x H) | 50 x 50 x 28 cm |
| Peso | 7 kg |
| Temperatura de funcionamento | 0-40 °C (32-104 °F) |
| Humidade | 0-90% RH (sen condensación) |
9. Garantía e soporte
9.1 Información da garantía
Specific warranty terms and conditions may vary by region and retailer. Please refer to the warranty card included with your product or contact your point of purchase for detailed warranty information.
9.2 Soporte técnico
For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact the retailer or the manufacturer, CSG S.A., directly. Contact information can typically be found on the product packaging or the manufacturer's official websitio.