Introdución
This user manual provides essential information for the safe and efficient installation, operation, and maintenance of your SFA Sanicondens Clim mini S condensate pump. Please read these instructions carefully before installation and keep them for future reference. This pump is designed to remove condensate from air conditioning units with a capacity of up to 8 kW (27,000 BTU).
Información de seguridade
- Always disconnect the power supply before performing any installation, maintenance, or repair work.
- Installation should be performed by a qualified professional in accordance with local electrical and plumbing codes.
- Do not operate the pump if it is damaged or if any electrical components are exposed.
- Asegúrese de que a bomba estea instalada nun lugar protexido das temperaturas de conxelación.
- This pump is designed for condensate removal from air conditioning units only. Do not use it for other liquids or applications.
Configuración e instalación
The SFA Sanicondens Clim mini S pump is designed for discreet installation, typically within the air conditioning unit or a nearby conduit. Follow these steps for proper setup:
1. Desembalaxe e inspección
Carefully remove all components from the packaging. Inspect the pump and accessories for any signs of damage. Do not install if damaged.

Figura 1: The SFA Sanicondens Clim mini S condensate pump (left) and its separate reservoir (right).
2. Component Identification and Dimensions
Familiarize yourself with the pump components and their dimensions to ensure proper fit and installation space.

Figura 2: Technical drawing showing the dimensions of the pump and reservoir unit in millimeters.
3. Placement and Connection
The pump consists of two main parts: the detection unit (reservoir) and the pump unit. The detection unit should be placed to collect condensate directly from the air conditioning unit's drain pan. The pump unit can be installed remotely, connected to the detection unit via a small tube and electrical cable.

Figura 3: Installation diagram. (A) Air conditioner drain, (B) Detection unit, (C) Pump unit, (D) Check valve, (E) Discharge pipe leading to drain.
- Connect the condensate drain hose from the air conditioning unit to the inlet of the detection unit.
- Connect the small tube and electrical cable from the detection unit to the pump unit.
- Attach the discharge pipe to the pump unit's outlet. Ensure a check valve is installed to prevent backflow.
- Route the discharge pipe to a suitable drain point, ensuring it has a continuous downward slope after reaching its maximum lift height. The pump can lift water up to 78.74 inches (approximately 2 meters).
- Connect the pump to a 230 Volt electrical supply.

Figura 4: Example of a discreet installation of the SFA Sanicondens Clim mini S pump with an air conditioning unit.
Instrucións de funcionamento
The SFA Sanicondens Clim mini S condensate pump operates automatically. Once properly installed and connected to power, it will activate when the condensate level in the detection unit reaches a predetermined level, pumping the water away. It will then switch off once the level drops.
- Ensure the air conditioning unit is producing condensate for the pump to operate.
- Listen for the pump's operation. It is designed to be quiet (21 dB).
- O caudal máximo é de 9 litros por hora.

Figura 5: Pump performance curve showing head (H in meters) versus flow rate (Q in L/h). The solid line indicates typical operating range.
Mantemento
Regular maintenance ensures the longevity and efficient operation of your condensate pump.
- Limpeza anual: At least once a year, clean the filter screen in the detection unit to prevent blockages.
- Inspección: Periodically check all connections for leaks and ensure the discharge pipe is free from kinks or obstructions.
- Desconexión de alimentación: Always disconnect the pump from the power supply before performing any cleaning or inspection.
Resolución de problemas
If you encounter issues with your SFA Sanicondens Clim mini S pump, refer to the following common problems and solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| A bomba non arranca | No power; float switch stuck; clogged inlet. | Check power supply; inspect float for free movement; clean inlet and filter screen. |
| A bomba funciona continuamente | Float switch stuck; discharge pipe blocked or kinked; check valve faulty. | Inspect float; clear discharge pipe; check check valve for proper function. |
| Fuga de auga | Loose connections; damaged hose/pipe. | Tighten all connections; replace damaged components. |
| Ruído excesivo | Vibrations; air in the system; pump not securely mounted. | Ensure secure mounting; bleed air from system if possible; check for obstructions. |
Se o problema persiste despois de intentar estas solucións, póñase en contacto co persoal de servizo cualificado.
Especificacións
| Característica | Detalle |
|---|---|
| Número de modelo | CLIMMINI3S |
| Marca | SFA |
| Caudal máximo | 9 Liters per hour (L/h) |
| Altura máxima de elevación | 78.74 polgadas (aprox. 2 metros) |
| Fonte de enerxía | Cable eléctrico |
| Voltage | 230 voltios |
| Enerxía Eléctrica | 22 vatios |
| Nivel de son | 21 decibeis (dB) |
| Dimensions (Pump Unit) | 10.5 x 3.2 x 5.4 cm (aprox. 4.1 x 1.3 x 2.1 polgadas) |
| Peso | 390 g (aprox. 0.86 libras) |
| Material | Plástico |
| Suitable for AC units up to | 8 kW / 27,000 BTU |
Información da garantía
SFA products are manufactured to high-quality standards. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official SFA websitio. Garda o comprobante de compra para reclamacións de garantía.
Atención ao cliente
For technical assistance, spare parts, or service inquiries, please contact SFA customer support or your local distributor. Contact information can typically be found on the SFA official websitio ou na embalaxe do produto.





