1. Introdución
The AUTOOL SDT203 Smoke Leak Detector is an essential tool for automotive technicians and DIY enthusiasts. It is designed to quickly and accurately locate leaks in various vehicle systems, including:
- Fuel Pipe Systems
- Sistemas de admisión de aire
- Cooling Tanks
- EVAP (Evaporative Emission Control) Systems
- Sistemas de escape
- Varios accesorios para tubos
By generating a visible smoke, the device allows for easy identification of leaks that might otherwise be difficult to detect, improving diagnostic efficiency and accuracy.
2. Información de seguridade
Lea e comprenda todos os avisos de seguridade antes de operar o dispositivo para evitar lesións ou danos.
- Ventilación: Utilice o dispositivo nunha zona ben ventilada.
- Fonte de enerxía: Use only a 12V DC power source. Ensure correct polarity when connecting to the vehicle battery.
- Test Oil: Use only approved test oil (mineral oil or baby oil). Do not use flammable liquids.
- Superficies quentes: The device generates heat during operation. Avoid touching hot surfaces.
- Smoke Inhalation: Avoid direct inhalation of smoke. While the smoke is generally non-toxic, prolonged exposure is not recommended.
- Protección ocular: Always wear appropriate eye protection during operation.
- Protección contra sobrecalentamento: The device has built-in overheat protection. If the temperature exceeds 75°C, power protection will activate to turn it off.
- Protección antixeo: The device is designed to operate normally down to -20°C.
3. Produto rematadoview e Compoñentes
The SDT203 Smoke Leak Detector comes with the main unit and several accessories to facilitate various leak detection tasks.

Figure 3.1: AUTOOL SDT203 Smoke Leak Detector and Accessories
Características da unidade principal:

Figure 3.2: SDT203 Main Unit Components
- Manómetro: Displays the system pressure during testing.
- Recheo de aceite: Porto para engadir aceite de proba.
- Oil Level Gauge: Indicates the current level of test oil.
- Medidor de caudal: Allows monitoring and adjustment of smoke output flow.
- Power Socket & Smoke Outlet: Connection points for power and smoke hose.
- Válvula de control de fluxo: Adjusts the smoke output rate.
- LED de alimentación: Indica o estado da enerxía.
- LED de fume: Indicates smoke generation status.
- Gancho: For convenient hanging under the vehicle hood.
Accesorios incluídos:
- Power Cables (with alligator clips for 12V battery connection)
- Smoke Output Hose
- Funnel for oil filling
- Various Adapters (e.g., EVAP service port adapter, universal cone adapter)
- Manual de usuario
4. Especificacións

Figure 4.1: SDT203 Technical Specifications
| Parámetro | Valor |
|---|---|
| Dimensións da unidade principal | 190 x 130 x 85 mm (7.5 x 5.1 x 3.3 polgadas) |
| Peso do elemento | 2.5 kg (5.46 libras) |
| Presión de saída | <1.2 bar |
| Fluxo de saída | 7 l/min |
| Saída de presión de aire | Bomba de aire incorporada |
| Fonte de alimentación | Batería DC 12V |
| Humidade de funcionamento | 95 % |
| Tipo de alarma | Audible |
5. Configuración
Follow these steps to set up your SDT203 Smoke Leak Detector for operation.
- Fill with Test Oil:
Unscrew the oil filler cap on top of the device. Using the provided funnel, inject 20-30ml of fresh mineral oil or baby oil into the machine. Do not overfill. Replace the cap securely.
Figure 5.1: Filling Test Oil
- Conectar enerxía:
Connect the power cables to the device's power socket. Then, connect the red alligator clip to the positive (+) terminal of a 12V vehicle battery and the black alligator clip to the negative (-) terminal. The Power LED on the device should illuminate.
Figure 5.2: Connecting to 12V Battery
- Connect Smoke Duct:
Attach the smoke output hose to the smoke outlet port on the device. Ensure a secure connection.
6. Instrucións de funcionamento
Once set up, you can begin the leak detection process.
- Preparar o sistema:
Disconnect the pipe or system component that needs to be tested from the vehicle. Seal off any open ends of the system not being tested to create a closed environment for smoke injection. - Turn On Smoke Generation:
Flip the smoke switch on the device to the 'ON' position. The Smoke LED will illuminate, and the device will begin generating smoke. Smoke output should be visible within 30 seconds.
Figure 6.1: Smoke Output
- Adjust Flow Meter:
Use the flow control valve to adjust the smoke output rate. The external flow meter allows you to monitor the flow, which is crucial for different pipe systems that may require varying air pressures. Adjusting the flow prevents damage from excessive pressure and ensures effective leak detection.Video 6.1: Demonstration of SDT203 Leak Detector in use, showing pressure gauge display, smoke output, intake system test, and adjustable flow meter.
This video demonstrates the setup and operation of the SDT203, including connecting power, attaching the smoke duct, observing the pressure gauge, and adjusting the flow meter for effective leak detection in an intake system.
- Inject Smoke:
Insert the smoke output nozzle into the system being tested. The system will fill with smoke. - Locate Leaks:
Observe the system for visible smoke escaping from any points. The external pressure gauge can also help: if the pressure drops significantly or does not build up, it indicates a leak. Repair the identified leak points. - EVAP System Detection:
For American cars produced after 1996, locate the EVAP service port (usually in the engine compartment). Use a spool wrench to remove the check valve clockwise, then install the EVAP service port adapter. Introduce smoke from this port into the EVAP system to detect leaks.

Figura 6.2: Ampla gama de aplicacións
The SDT203 is suitable for a wide range of vehicles, including cars, motorcycles, snowmobiles, off-road vehicles, ATVs, light trucks, and speedboats.
7. Mantemento
Proper maintenance ensures the longevity and optimal performance of your SDT203 Smoke Leak Detector.
- Nivel de aceite: Regularly check the oil level using the oil level gauge. Refill when low to prevent dry burning.
- Limpeza: After use, wipe down the exterior of the device with a clean, dry cloth.
- Almacenamento: Store the device in a cool, dry place away from direct sunlight and extreme temperatures. Ensure all hoses and accessories are neatly stored to prevent damage.
- Tipo de aceite: Always use the recommended test oil (mineral oil or baby oil). Using incorrect oil can damage the heating element or pump.
8 Solución de problemas
If you encounter issues with your SDT203, refer to the following common problems and solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| Sen saída de fume | Low or no test oil Potencia non conectada Smoke switch off | Refill test oil Check 12V power connection Turn smoke switch ON |
| Sen lectura de presión no manómetro | System not sealed Mangueira desconectada Internal pump issue | Ensure all openings are sealed Check smoke hose connection Contact support if pump fails |
| Cannot find leak | Insufficient smoke time Caudal demasiado baixo Leak is very small | Allow more time for smoke to fill system Increase flow rate with control valve Use a bright light to inspect closely |
| Device overheats and shuts off | Uso continuado prolongado Ventilación deficiente | Permitir que o dispositivo se arrefríe Ensure adequate airflow around device |
9. Garantía e soporte
AUTOOL provides comprehensive support for the SDT203 Smoke Leak Detector.
- Garantía: For damages caused by non-human factors, AUTOOL promises to resend parts for free within 3 years from the date of purchase.
- Mantemento ao longo da vida: AUTOOL is committed to providing lifelong maintenance support for the product.
- Atención ao cliente: For any inquiries, technical assistance, or warranty claims, please contact AUTOOL customer support. We aim to reply as soon as possible within 24 hours.
Please visit the official AUTOOL website or refer to the contact information provided with your purchase for the most up-to-date support details.