1. Introdución
This manual provides detailed instructions for the safe and effective operation of your MATRIX MPS-3010H-3 Triple Output DC Power Supply. This device is a high-precision, stable, and adjustable linear DC bench power supply designed for various applications including laboratory work, electronic repair, DIY projects, and scientific research. Please read this manual thoroughly before use to ensure proper functionality and safety.

Fronte view of the MATRIX MPS-3010H-3 DC Power Supply, showcasing its triple output capabilities and digital displays, along with the included test leads and power cable.
2. Instrucións de seguridade
To prevent electric shock, fire, or damage to the product, observe the following safety precautions:
- Asegúrese de que a entrada voltage switch (110V/220V) on the rear panel matches your local power supply before connecting the power cord.
- Conecte sempre a fonte de alimentación a unha toma de corrente con conexión a terra.
- Non utilice o dispositivo en lugares húmidos ou damp condicións.
- Evite bloquear as aberturas de ventilación para evitar o sobrequecemento.
- Non intente reparar nin modificar a unidade vostede mesmo. Encargue todo o mantemento a persoal cualificado.
- Ensure output terminals are correctly connected to the load. Incorrect polarity can damage the device or the connected circuit.
- Always turn off the power supply and disconnect the load before making or changing connections.
- Be aware of potential voltage overshoot when using the output switch, especially with sensitive loads. It is recommended to connect the load after setting the desired voltage and current, and then enable the output.
3. Características do produto
The MATRIX MPS-3010H-3 offers advanced features for precise and reliable power delivery:
- High Accuracy and Stability: 4-digit LED display with 10mV/1mA high resolution. Voltage precision <0.01%+8mV, Current precision <0.1%+5mA.
- Low Ripple and Noise: Less than 2mVrms ripple and noise ensures clean power output.
- Precision Encoder Adjustment Knobs: Four encoder knobs for precise, single-unit value adjustments, with protection against accidental changes.
- One-key Series and Parallel Function: Easily switch between series and parallel configurations for CH1 and CH2 without manual rewiring.
- Protección integral: Includes Over Current Protection (OCP), Over Voltage Protection (OVP), and Over Temperature Protection (OTP).
- Smart Fan System: Quiet, intelligent temperature-controlled fan for efficient cooling.
- Función de memoria: Power-on memory status retains previous settings.
- Switchable Input Voltage: Supports 110V/220V input for global compatibility.
- Control independente: Channels 1 and 2 can be controlled and output independently.

This image highlights the 4-digit LED display of the power supply, demonstrating its high precision and stable output with 10mV/1mA resolution, crucial for sensitive electronic work.
4. Produto rematadoview
4.1 Controis e indicadores do panel frontal

A comprehensive diagram of the front panel, identifying all controls, displays, and output terminals for channels CH1, CH2, and CH3, including adjustment knobs, output switches, and indicator lights.
- CH1 Current Display Window
- CH1 Voltage Display Window
- CH2 Current Display Window
- CH2 Voltage Display Window
- CH1 Output Switch
- CH2 Current Adjustment Knob
- CH2 Voltage Botón de axuste
- Indicador de sobrecarga CH3
- Terminal de saída CH3
- CH2 Constant Current Indicator (CC)
- CH2 Constant Voltage Indicator (CV)
- Terminal de saída CH2
- Terminal terrestre
- CH1 Voltage Botón de axuste
- Terminal de saída CH1
- Instrument Power Switch
- CH1 Current Adjustment Knob
- One-key Series/Parallel Function Button
- Series and Parallel Indicator Lights
- CH1 Constant Current Indicator (CC)
- CH1 Constant Voltage Indicator (CV)
4.2 Conexións do panel traseiro

A diagram of the power supply's rear panel, indicating the power outlet, fuse holder, 110V/220V input switch, and the intelligent temperature control fan for proper setup and maintenance.
- Toma de corrente: Connects to the AC power cord.
- Portafusibles: Contén o fusible de protección.
- 110V/220V Input Switch: Selecciona o volume de entrada adecuadotage.
- Ventilador intelixente de control de temperatura: Provides cooling for the unit.
5. Instrucións de configuración
- Desembalaxe: Carefully remove the power supply and all accessories from the packaging. Verify that all components are present (power supply unit, power cord, test leads, user manual).
- Vol. De entradatage Selección: Locate the 110V/220V switch on the rear panel. Use a flat-head screwdriver to set the switch to match your local AC power voltage (110V for North America, 220V for most of Europe and Asia). Failure to do so may damage the unit.
- Colocación: Place the power supply on a stable, level surface, ensuring adequate ventilation around the unit. Do not block the fan vents on the rear panel.
- Conexión de alimentación: Connect the provided power cord to the power outlet on the rear panel and then to a grounded AC power outlet.
- Encendido inicial: Press the instrument power switch on the front panel to turn on the unit. The displays should illuminate.
6. Instrucións de funcionamento
6.1 Volume básicotage e Configuración actual
- Ensure the power supply is on and no load is connected to the output terminals.
- Configuración Voltage: For CH1 or CH2, press the respective Voltage Adjustment Knob (14 or 7) to activate adjustment. Turn the knob to set the desired voltage. The 4-digit display allows for precise adjustments.
- Configuración actual: For CH1 or CH2, press the respective Current Adjustment Knob (17 or 6) to activate adjustment. Turn the knob to set the desired current limit.
- Carga de conexión: Despois de axustar o volume desexadotage and current, connect your load to the appropriate output terminals (15 for CH1, 12 for CH2, 9 for CH3).
- Activar saída: Press the CH1 Output Switch (5) or CH2 Output Switch (13) to enable power output to the connected load. The display will show the actual output voltage e corrente.
Note on Output Switch: When enabling output, especially with sensitive loads, there can be a brief current overshoot. It is recommended to set voltage and current limits with the output disabled, connect the load, and then enable the output. For highly sensitive circuits, consider using an external switch or connecting the load after the power supply has stabilized.

A detailed image focusing on the coded switch knob, which provides quick and easy push-in adjustments, offering a more user-friendly experience compared to traditional fine and coarse adjustments.
6.2 Series and Parallel Mode Operation
The MPS-3010H-3 allows for easy configuration of CH1 and CH2 in series or parallel mode:
- Preparación: Ensure both CH1 and CH2 outputs are disabled.
- Seleccionar modo: Press the One-key Series/Parallel Function Button (18). The corresponding indicator light (19) will illuminate for either SERIES or PARALLEL.
- Series Mode: In series mode, the output voltage of CH1 and CH2 adds up (e.g., 30V + 30V = 60V), while the current remains at the set limit of the master channel. The display will show the combined voltage e corrente.
- Modo paralelo: In parallel mode, the output current of CH1 and CH2 adds up (e.g., 10A + 10A = 20A), while the voltage remains at the set limit of the master channel. The display will show the combined current and voltage.
- Activar saída: After selecting the mode, enable the output for both channels.
6.3 Protection Functions (OCP/OVP/OTP)
- OCP (protección contra sobrecorriente): If the output current exceeds the preset limit, the power supply will enter constant current (CC) mode, limiting the current to the set value. The CC indicator will light up.
- OVP (Over Voltage Protección): Se a saída voltage exceeds a preset maximum, the power supply will shut down the output to protect the load.
- OTP (Protección contra sobretemperatura): If the internal temperature of the power supply exceeds a safe operating limit, the unit will automatically shut down to prevent damage.
6.4 Outras opcións
- Son clave: The power supply features an option to turn off the key sound for a noise-free experience. Refer to the on-screen menu for this setting.
- Estado da memoria: The unit retains its last settings upon power-off and restores them when powered on again.
7. Mantemento
- Limpeza: Disconnect the power supply from the AC outlet and all loads before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use abrasive cleaners or solvents.
- Ventilación: Regularly check that the ventilation openings and fan are free from dust and debris. Use compressed air to clear any blockages.
- Almacenamento: Cando non a use durante períodos prolongados, garde a fonte de alimentación nun lugar fresco e seco, lonxe da luz solar directa e de temperaturas extremas.
- Substitución de fusibles: If the unit does not power on, check the fuse in the fuse holder on the rear panel. Replace with a fuse of the same type and rating only.
8 Solución de problemas
Esta sección aborda problemas comúns cos que podes atoparte:
- A unidade non se acende:
- Comprobe se o cable de alimentación está ben conectado.
- Verify the 110V/220V input switch on the rear panel is set correctly.
- Check and replace the fuse if blown.
- Sen saída Voltage/Actual:
- Ensure the CH1/CH2 output switches are enabled.
- Check if OCP or OVP is active (indicators will light up). Adjust current/voltage limits if necessary.
- Verify load connections are correct and not short-circuited.
- Dim Green Voltage Pantalla:
- Some early units may have a dimmer green voltage display compared to the red current display. MATRIX has addressed this with upgraded displays. Contact customer support for assistance if your unit exhibits this issue.

An image demonstrating the improved brightness of the green voltage display on the MPS-H-3 model, making readings clearer and easier to see, with a 'before' example of a dimmer display.
- Voltage Overshoot on Output Enable:
- As noted in section 6.1, a brief overshoot can occur. For sensitive loads, ensure the output is disabled while connecting the load and setting parameters. Enable output only after the load is securely connected and parameters are set.
9. Especificacións
| Característica | Especificación |
|---|---|
| Modelo | MPS-3010H-3 |
| Vol. De saídatage | 0-30V (CH1, CH2) |
| Corrente de saída | 0-10A (CH1, CH2) |
| Potencia de saídatage | 615 vatios (total) |
| Voltage Resolución | 10mV |
| Resolución actual | 1 mA |
| Voltage Precisión | <0.01 %+8 mV |
| Current Precision | <0.1 %+5 mA |
| Ripple & Noise (Voltage) | <2 mVrms |
| Vol. De entradatage | Conmutable 110V/220V |
| Dimensións do produto (L x W x H) | 9.8 x 6 x 13 polgadas |
| Peso do elemento | 29.2 libras |
| Método de arrefriamento | Air (Intelligent Temperature Control Fan) |
| Protección | OCP, OVP, OTP |

This image provides the physical dimensions of the power supply (9.8 inches L x 6 inches W x 13 inches H), useful for placement and space planning.
10. Garantía e soporte
MATRIX offers a 3 ano de garantía for all MATRIX-branded products. Each power supply undergoes rigorous quality testing and calibration before leaving the factory.
For technical support, warranty claims, or any issues, please contact MATRIX customer service. Refer to the contact information provided with your purchase or visit the official MATRIX websitio para obter detalles de asistencia.