ELEGRP R1615D42-WH

ELEGRP 15 Amp USB Wall Outlet with Type A & Type C Ports Instruction Manual

Model: R1615D42-WH

1. Introdución

This manual provides essential instructions for the safe installation, operation, and maintenance of your ELEGRP 15 Amp USB Wall Outlet. Please read this manual thoroughly before installation and retain it for future reference.

The ELEGRP USB Wall Outlet is designed to provide both standard AC power receptacles and convenient USB charging ports (Type A and Type C) in a single unit. It features tamper-resistant shutters for safety and a dedicated charging port controller for optimized device charging.

2. Información de seguridade

ADVERTENCIA: RISCO DE DESCARGA ELÉCTRICA OU INCENDIO. UNHA INSTALACIÓN INADECUADA PODE PROVOCAR LESIÓNS GRAVES OU A MORTE.

3. Contido do paquete

Six ELEGRP 15 Amp USB Wall Outlets with wall plates

Image: Multiple ELEGRP 15 Amp USB Wall Outlets, showing the product as packaged.

4. Especificacións

CaracterísticaDetalle
Valoración do receptáculo15 Amp, 125 Volt AC
Tipo de receptáculoNO 5-15R
USB Rating (Total)5 V CC, 4.2 Amp
Saída USB tipo A.5 V CC, 2.4 Amp (Máximo)
USB Type C Output5 V CC, 3.0 Amp (Máximo)
Compatibilidade con calibre de cable#14 - #12 AWG Copper Wire
Tipo de cableadoSide Wiring and Back Wiring
Temperatura de funcionamento-4 °F a 104 °F (-20 °C a 40 °C)
Dimensións do produto4.17"L x 1.69"W x 1.65"D (106x43x42mm)
MaterialPolicarbonato termoplástico
CertificaciónsListado UL
Product dimensions and detailed specifications table for ELEGRP USB outlet

Image: Diagram showing the physical dimensions and a summary of product specifications.

5. Instalación (Configuración)

  1. Apagar a enerxía: Locate the circuit breaker or fuse box controlling the outlet you intend to replace. Turn off the power to that circuit. Verify power is off using a voltagprobador.
  2. Eliminar a antiga toma: Unscrew and carefully remove the existing wall plate and outlet from the electrical box. Disconnect the wires from the old outlet, noting which wire connects to which terminal (hot, neutral, ground).
  3. Prepare fíos: If necessary, strip approximately 1/2 inch (12.7 mm) of insulation from the ends of the wires. Ensure wires are straight and free of nicks.
  4. Conecte cables: The ELEGRP USB Wall Outlet supports both side wiring and back wiring.
    • Green Screw: Connect the bare copper or green insulated ground wire to the green screw terminal.
    • Silver Screw: Connect the white (neutral) wire to the silver screw terminal.
    • Brass Screw: Connect the black (hot) wire to the brass screw terminal.

    Note: All screws are pre-loosened for easier installation.

  5. Mount New Outlet: Carefully fold the wires into the electrical box. Insert the new ELEGRP USB Wall Outlet into the box and secure it with the provided mounting screws.
  6. Instalar placa de parede: Attach the new wall plate over the installed outlet.
  7. Restaurar enerxía: Volva conectar a corrente no disxuntor ou na caixa de fusibles.
  8. Salida de proba: Test both the AC receptacles and the USB ports to ensure proper functionality.
Wiring diagram for ELEGRP USB outlet showing side and back wire connections

Image: Detailed wiring diagrams for both side and back wire connections.

6. Instrucións de funcionamento

6.1 AC Receptacles

6.2 portos de carga USB

Smartphone charging via ELEGRP USB Type C port, demonstrating high-speed charging

Image: A smartphone connected to the USB Type C port of the outlet, illustrating charging speed.

Various devices like iPad, phone, camera, power bank, headset, watch, and Nintendo Switch shown compatible with ELEGRP USB outlet

Image: A visual representation of various devices compatible with the USB charging ports.

7. Mantemento

Comparison of ELEGRP outlet with advanced heat management versus a conventional outlet showing higher temperature

Image: A comparison illustrating the superior heat management of the ELEGRP outlet compared to other models.

8 Solución de problemas

9. Garantía e soporte

ELEGRP products are manufactured to high-quality standards. For warranty information or technical support, please refer to the warranty card included with your purchase or contact ELEGRP customer service directly.

Información de contacto: Please visit the official ELEGRP websitio web ou consulte a embalaxe do produto para obter os datos de contacto máis actuais.

Documentos relacionados - R1615D42-WH

Preview Guía de instalación do receptáculo combinado ELEGRP e do cargador USB
Instrucións de instalación detalladas e especificacións para o receptáculo combinado ELEGRP e o cargador USB, incluíndo características, diagramas de cableado, compatibilidade e avisos de seguridade.
Preview Guía de instalación do cargador e receptáculo combinado USB ELEGRP R16
Instrucións de instalación, especificacións e avisos de seguridade para o receptáculo e cargador combinado USB ELEGRP R16. Inclúe dous portos USB, toma de corrente estándar e cableado sinxelo. Inclúe garantía e cumprimento da normativa FCC.
Preview Instrucións de instalación do receptáculo combinado/cargador USB
Instrucións de instalación para o receptáculo combinado/cargador USB, que detallan as características, as especificacións, a compatibilidade e os diagramas de cableado. Inclúe avisos e precaucións de seguridade.
Preview Guía de instalación do interruptor de luz intelixente con regulador de intensidade ELEGRP
Este documento ofrece instrucións de instalación para o interruptor de luz intelixente con regulador de intensidade ELEGRP, que abarcan configuracións unipolares e de 3 vías. Detalla o cableado, a configuración e a compatibilidade con asistentes domésticos intelixentes como Alexa e o Asistente de Google.
Preview Manual do usuario do dispositivo doméstico intelixente ELEGRP: Conexión de aplicacións e dispositivos
Manual de usuario completo para dispositivos domésticos intelixentes ELEGRP, que detalla como descargar a aplicación ELEGRP HOME, conectar dispositivos a través de Wi-Fi (só 2.4 GHz) e integrar con Amazon Alexa e Google Assistant.
Preview ELEGRP Atenuador de LED/Fluorescente Compacto/Incandescente: Guía de Instalación DM17/DM17N
Instrucciones detalladas para la instalación del atenuador de luz ELEGRP modelo DM17/DM17N, compatible con luces LED, fluorescentes compactas e incandescentes. Cubre aplicaciones de un solo polo y de 3 vías.