Xetron STC-1000Pro

Manual do usuario do controlador de temperatura dixital Xetron STC-1000Pro

Model: STC-1000Pro | Brand: Xetron

1. Introdución

The Xetron STC-1000Pro is a versatile digital temperature controller designed for precise temperature management in various environments. It features dual outlets for simultaneous heating and cooling control, a wide temperature range, and user-friendly operation. This manual provides detailed instructions for setting up, operating, and maintaining your device.

Xetron STC-1000Pro Digital Temperature Controller with power cord, sensor, and dual outlets

Figure 1: Xetron STC-1000Pro Digital Temperature Controller. This image displays the main unit with its digital display, control buttons, power cord, temperature sensor, and the dual-outlet power strip for heating and cooling devices.

Aplicacións

The STC-1000Pro is suitable for a wide range of applications requiring accurate temperature control, including:

Various applications of the Xetron STC-1000Pro controller

Figure 2: Common applications for the Xetron STC-1000Pro. This image illustrates the controller's use in home brewing, incubators, aquariums, and flower cultivation, highlighting its versatility.

2. Características clave

Xetron STC-1000Pro maintaining temperature range

Figure 3: Temperature control range of the Xetron STC-1000Pro. This image highlights the controller's ability to maintain temperatures within a desired range of -40 to 230 ℉ using both cooling and heating devices.

Xetron STC-1000Pro large screen display with dimensions

Figure 4: Large screen display of the Xetron STC-1000Pro. The image shows the display dimensions and labels for PV (Present Value), SV (Set Value), Csp (Cooling Start Point), and Hsp (Heating Start Point), indicating ℃/℉ switchability.

Xetron STC-1000Pro visual and audible alerts

Figure 5: Visual and audible alert features. This image illustrates the double alarm and delay protection functionalities of the controller, enhancing safety and monitoring.

Xetron STC-1000Pro safety certifications

Figure 6: Safety and quality certifications. The image highlights the V-0 flame-retardant ABS material and compliance with CE, FCC, and RoHS standards, ensuring product safety.

Xetron STC-1000Pro IP65 waterproof probe

Figure 7: IP65 waterproof features. This image demonstrates the waterproof capability of the temperature probe, which can be immersed in fresh water, and the internal rubber ring for main unit protection.

3. Instrucións de configuración

  1. Desempaquetar o dispositivo: Carefully remove the Xetron STC-1000Pro controller and its components from the packaging.
  2. Conecta o sensor: Ensure the temperature sensor is fully inserted into its dedicated port on the side of the controller. A loose connection can lead to "ERR" display.
  3. Posicionar o sensor: Place the temperature probe in the environment where temperature monitoring and control are required. Ensure it is not directly exposed to heating or cooling elements to get an accurate reading.
  4. Conectar dispositivos de calefacción/refrixeración:
    • Plug your heating device (e.g., heat lamp, heating mat) into the socket labeled "HEATING".
    • Plug your cooling device (e.g., fan, chiller) into the socket labeled "COOLING".

    Importante: The maximum output for each socket is 10A at 240VAC. Do not connect high-power equipment exceeding these limits.

  5. Encendido: Plug the controller's main power cord into a standard 230V AC power outlet. The display will illuminate, showing the current temperature (PV) and other settings.
Xetron STC-1000Pro plug and play setup

Figure 8: Plug-and-play setup of the Xetron STC-1000Pro. This image demonstrates the simplicity of connecting the controller, showing it mounted on a wall next to a terrarium, with heating/cooling devices plugged in.

4. Instrucións de funcionamento

The STC-1000Pro features a simple 3-button interface: SET, ARRIBA (▲), e ABAIXO (▼).

4.1 Mostrar máisview

4.2 Axuste da temperatura obxectivo (SV)

  1. Preme o SET button once. The SV value will flash.
  2. Usa o ARRIBA (▲) or ABAIXO (▼) buttons to adjust the target temperature.
  3. Preme SET again to confirm and save the setting, or wait a few seconds for it to save automatically.

4.3 Configuración avanzada de parámetros

Para acceder á configuración avanzada, manteña premida a tecla SET button for approximately 3 seconds until the display changes to show parameter codes.

Xetron STC-1000Pro parameter setting diagram

Figure 9: Diagram illustrating parameter settings. This image shows the relationship between TS (Temperature Set-point), CD (Cooling Differential), HD (Heating Differential), Csp (Cooling Start Point), and Hsp (Heating Start Point).

Usa o ARRIBA (▲) or ABAIXO (▼) buttons to navigate through the parameters. Press SET to enter a parameter's value, then use ARRIBA (▲) or ABAIXO (▼) para axustar, e SET de novo para gardar.

Table 1: Advanced Parameters
ParámetroDescriciónRangoPor defecto
TS (Temperature Set-point)The desired target temperature (same as SV).-40 a 110 ℃ / -40 a 230 ℉Varía
CD (Cooling Differential)The difference between the cooling start point (Csp) and the set temperature (TS). Cooling activates when PV ≥ TS + CD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
HD (Heating Differential)The difference between the heating start point (Hsp) and the set temperature (TS). Heating activates when PV ≤ TS - HD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
PT (Protection Time)Compressor delay protection time (in minutes) for cooling mode only. Prevents frequent compressor cycling.0 a 10 minutosminutos 3
CA (Temperature Calibration)Adjusts the temperature reading to match an external reference thermometer.-10 a 10 ℃ / -18 a 18 ℉0 ℃ / 0 ℉
CF (Unit Switch)Switches between Celsius (℃) and Fahrenheit (℉).C/FC
HA (High Alarm)Sets the upper temperature limit for the alarm.TS to 110 ℃ / TS to 230 ℉110 ℃ / 230 ℉
LA (Low Alarm)Sets the lower temperature limit for the alarm.-40 ℃ / -40 ℉ to TS-40 ℃ / -40 ℉

After adjusting parameters, press and hold SET again for 3 seconds to exit the advanced settings menu and return to normal operation.

5. Mantemento

6 Solución de problemas

Táboa 2: Guía de resolución de problemas
ProblemaCausa posibleSolución
"ERR" displayed on screenTemperature sensor not fully inserted or damaged; temperature exceeds measurement range.Ensure the sensor is fully inserted into its port. If the issue persists, the sensor may be faulty and require replacement. If the temperature is outside the -40 to 110 ℃ range, the controller will display "ERR".
Alarm sounds and bell icon appearsCurrent temperature (PV) has exceeded the set high alarm (HA) or fallen below the low alarm (LA) threshold.Check the environmental conditions. Adjust HA/LA settings if necessary. The controller will disable all outputs in fault alarm mode to protect equipment.
O dispositivo de calefacción/refrixeración non se activaIncorrect temperature settings (TS, CD, HD); compressor delay protection (PT) active; device not properly plugged in; device malfunction.Verify TS, CD, and HD settings. Wait for the PT delay to expire in cooling mode. Ensure devices are securely plugged into the correct outlets. Test heating/cooling devices independently.
Lectura de temperatura inexactaSensor placement; temperature calibration (CA) offset.Relocate the sensor to a more representative area. Use the CA parameter to calibrate the reading against a known accurate thermometer.

7. Especificacións

Táboa 3: Especificacións do produto
CaracterísticaDetalle
Número de modeloXT-STC1000Pro-01US
MarcaXetron
Voltage230V AC (Note: Product description mentions 230V, specifications mention 110V. User should verify their specific model's voltagrequisitos electrónicos).
Corriente de saída máxima10A por toma
Rango de control de temperatura-40 ℃ a 110 ℃ (-40 ℉ a 230 ℉)
Precisión da temperatura±1 ℃ / ±2 ℉
Tipo de visualizaciónOLED
MaterialFlame-retardant ABS Plastic
Dimensións do produto (L x W x H)20 x 15 x 6 cm
Peso400 gramos
Temperatura de funcionamentoUp to 110 ℃
Compoñentes incluídos1x Temperature Controller

8. Advertencias e precaucións de seguridade

9. Soporte e información de contacto

For any questions, technical assistance, or customer service inquiries regarding your Xetron STC-1000Pro Digital Temperature Controller, please contact Xetron customer support. We are committed to providing satisfactory customer service.

Please refer to the product packaging or the retailer's websitio web para obter os datos de contacto máis actuais.

Documentos relacionados - STC-1000Pro

Preview Manual do usuario da serie de controladores de temperatura intelixentes Xetron STC-1000Pro TH
Manual de usuario completo para a serie de controladores de temperatura intelixentes Xetron STC-1000Pro TH, que detalla as súas características, funcionamento, instalación e especificacións técnicas para un control preciso da temperatura e a humidade.
Preview Manual de usuario del controlador de temperatura inteligente Xetron STC-1000Pro
Manual de usuario para o controlador de temperatura dixital intelixente Xetron STC-1000Pro. Detalla as características, o funcionamento, a instalación e as especificacións para un control preciso da temperatura en aplicacións como a elaboración caseira de cervexa, acuarios e incubación.
Preview Manual do usuario do controlador de temperatura intelixente Elitech STC-1000Pro/STC-1000WiFi | Características, funcionamento, configuración
Manual de usuario dos controladores de temperatura dixitais intelixentes Elitech STC-1000Pro e STC-1000WiFi. Obtén información sobre as características, o funcionamento, a configuración dos parámetros, a instalación, a resolución de problemas e a conectividade da aplicación para unha xestión precisa da temperatura.
Preview Manual do usuario do controlador de temperatura intelixente Elitech STC-1000Pro/STC-1000WiFi
Manual do usuario para os controladores dixitais intelixentes de temperatura Elitech STC-1000Pro e STC-1000WiFi. Abarca as características, a pantalla, o funcionamento, a configuración dos parámetros, a instalación, os códigos de erro e a integración da aplicación para unha xestión precisa da temperatura.