1. Introdución
This manual provides essential instructions for the safe and efficient operation, setup, and maintenance of your Yellow Jacket 93870 Bullet DC Vacuum Pump. This 7 CFM model is designed for various residential and commercial applications, offering high performance and reliability. Please read this manual thoroughly before using the pump to ensure proper function and to prevent damage or injury.
2. Información de seguridade
Observe sempre as seguintes precaucións de seguridade para reducir o risco de lesións ou danos no equipo:
- Seguridade eléctrica: Ensure the power source matches the pump's requirements. The pump features a non-sparking switch and a locking low-profile IEC connector for A2L compliance. Always connect to a grounded outlet.
- Equipos de protección individual (EPI): Wear appropriate safety glasses and gloves when handling refrigerants or vacuum pump oil.
- Ventilación: Operate the pump in a well-ventilated area. The wide mouth oil reservoir port can be threaded to attach a garden hose for exhausting to a remote location if needed.
- Superficies quentes: A bomba pode quentarse durante o funcionamento. Evite o contacto directo con superficies quentes.
- Manipulación de aceite: Use only recommended vacuum pump oil. Dispose of used oil responsibly according to local regulations.
- Compatibilidade do sistema: This pump is designed for use with A2L systems. Ensure compatibility with your specific application.
- Exposición á auga: The pump has an IPX4 rating, meaning it is resistant to water splashes from any direction. However, avoid submerging the unit or exposing it to heavy rain.
3. Produto rematadoview e Compoñentes
The Yellow Jacket 93870 Bullet DC Vacuum Pump is a high-performance, two-stage rotary vane pump featuring a brushless DC motor. Key components and features include:
- Motor DC sen escobillas: 1/2 HP motor providing high torque and efficiency.
- Intake Fittings: Multiple intake fittings (1/4in x 3/8in x 1/2in) for versatile connections.
- Oil Sight Glass: Elongated for easier monitoring of oil level and condition.
- Oil Reservoir Port: Wide mouth for easy filling and doubles as an exhaust port.
- Drenaxe de aceite: Large brass drain for convenient oil changes.
- Internal Intake Check Valve: Prevents oil backup into the system during power interruptions.
- Intake Filter Screen: Protects the pump from damaging particles.
- Aletas de refrixeración: Built-in for optimal pump cooling and increased performance.
- Heavy Duty Handle: Steel handle for easy transport.
- Mount Points: Built-in for an optional shoulder strap.
Figure 1: Yellow Jacket 93870 Bullet DC Vacuum Pump. This image shows the overall design of the vacuum pump, highlighting its compact form factor and robust construction.
4. Configuración
- Desembalaxe: Retire con coidado a bomba de baleiro da súa embalaxe. Inspeccione se hai algún dano durante o envío.
- Recheo de aceite: Locate the wide mouth oil reservoir port. Remove the cap and slowly fill the pump with Yellow Jacket SuperEvac™ Vacuum Pump Oil (or equivalent high-quality vacuum pump oil) until the oil level is visible in the middle of the elongated oil sight glass. Do not overfill.
- Conexión de alimentación: Connect the provided 9ft 10in (3 meter) power cord to the locking low-profile IEC connector on the pump and then to a suitable grounded electrical outlet. Ensure the connection is secure.
- Intake Connection: Select the appropriate intake fitting (1/4in, 3/8in, or 1/2in) for your system and connect your vacuum hose. Ensure all connections are tight to prevent leaks.
- Colocación: Place the pump on a stable, level surface in a well-ventilated area.
5. Instrucións de funcionamento
- Comprobación previa á operación: Verify the oil level is correct in the sight glass. Ensure all hose connections are secure.
- Iniciar a bomba: Turn the power switch to the 'ON' position. The pump will begin to operate.
- Evacuation Process: Allow the pump to run until the desired vacuum level is achieved. The Bullet DC Vacuum Pump is field rated to 25 microns, effectively removing contaminants and non-condensable gases from the system.
- Monitor Oil: Periodically check the oil sight glass during operation. If the oil appears cloudy or discolored, it may need to be changed.
- Apagar: Once evacuation is complete, close the valve on your manifold or system to isolate the vacuum pump. Turn the pump's power switch to the 'OFF' position.
- Desconectar: Carefully disconnect the vacuum hoses from the pump.
6. Mantemento
Regular maintenance ensures optimal performance and extends the life of your vacuum pump.
- Cambios de aceite: Change the vacuum pump oil frequently, especially after each use or if the oil appears cloudy, discolored, or contaminated. The small oil bath requires less oil, making changes quicker.
- Drenaxe de aceite: To change oil, place a suitable container under the large brass oil drain. Open the drain plug to allow the old oil to flow out. Close the drain plug once empty.
- Refilling Oil: Refill with fresh vacuum pump oil through the wide mouth oil reservoir port, observing the oil sight glass.
- Intake Filter Screen: Periodically inspect and clean the intake filter screen to prevent damaging particles from entering the pump.
- Limpeza xeral: Keep the exterior of the pump clean and free of debris. Ensure cooling fins are clear for efficient heat dissipation.
7 Solución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| A bomba non arranca | Sen corrente, interruptor defectuoso, problema co motor | Check power cord connection and outlet. Ensure switch is 'ON'. If problem persists, contact support. |
| Pump not pulling adequate vacuum | Leaking connections, contaminated oil, clogged intake filter, worn components | Check all hose connections for leaks. Change oil. Clean intake filter screen. If problem persists, contact support. |
| Oil backing up into system | Internal intake check valve issue (unlikely with proper function) | Ensure pump is shut off and isolated from the system before disconnecting. If oil backup occurs frequently, contact support. |
| Ruído ou vibración excesivos | Low oil level, contaminated oil, foreign object, worn bearings | Check and add oil. Change oil. Inspect intake for foreign objects. If noise persists, contact support. |
8. Especificacións
| Característica | Detalle |
|---|---|
| Número de modelo | 93870 |
| Caudal | 7 pés cúbicos por minuto (CFM) |
| Motor | Brushless DC 1/2 HP |
| Stages | Dous stage rotary vane |
| Field Rating | 25 micras |
| Accesorios de admisión | 1/4in x 3/8in x 1/2in |
| Fonte de enerxía | Battery Powered (DC) - Note: Refers to DC motor type, unit requires external power. |
| Material | Aceiro inoxidable |
| Dimensións do produto (L x W x H) | 17.5" x 6" x 11.99" |
| Peso do elemento | 32.5 libras |
| Características especiais | Lightweight, Non-sparking switch, Locking IEC connector, PX4 Rating |
| UPC | 686800938707 |
9. Garantía e soporte
The Yellow Jacket 93870 Bullet DC Vacuum Pump comes with a 24 meses de garantía desde a data de compra. Esta garantía cobre defectos de materiais e fabricación en condicións de uso normal.
For warranty claims, technical assistance, or to purchase replacement parts, please contact Yellow Jacket customer support. Keep your proof of purchase for warranty validation.
Note: Unauthorized repairs or modifications will void the warranty.