Xetron XT-LMG-10X-EU

Manual do usuario do manómetro dixital de colector Xetron HVAC

Model: XT-LMG-10X-EU

1. Introdución

The Xetron LMG-10X Digital Manifold Gauge is an advanced tool designed for HVAC and refrigeration systems. It provides precise measurements for pressure, temperature, vacuum, and automatically calculates superheat and subcooling. This manual will guide you through the setup, operation, and maintenance of your device.

Xetron LMG-10X Digital Manifold Gauge with probes and carrying case

Figure 1: Xetron LMG-10X Digital Manifold Gauge with included accessories.

2. Información de seguridade

Always read and understand all safety warnings and instructions before using the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Contido do paquete

Verifique que todos os elementos que se indican a continuación estean presentes no seu paquete:

Contents of the Xetron LMG-10X package: digital manifold and two clamp probes in a case.

Figure 2: What's in the box - Xetron Digital Manifold and Clamp Temperature Probes.

4. Configuración

4.1. Acendido inicial

  1. Insert batteries into the compartment on the back of the unit (if not pre-installed).
  2. Manteña premido o botón de acendido () para acender o dispositivo.
  3. The LCD screen will illuminate and display the initial measurement interface.

4.2. Connecting Probes and Hoses

Conecta o clamp temperature probes to the designated ports on the manifold. Ensure a secure connection. Refrigerant hoses (not included) can be connected to the 1/4" SAE threaded connectors at the bottom of the unit.

Xetron LMG-10X connected to an HVAC system, showing low side and high side control valves, refrigerant hose bracket, and metal cap.

Figure 3: Connecting the Xetron LMG-10X to an HVAC system.

5. Instrucións de funcionamento

5.1. Pressure and Temperature Measurement Mode

This mode displays real-time pressure and temperature readings, along with calculated saturation temperatures (VSAT, LSAT).

Diagram showing the Xetron LMG-10X display in pressure and temperature measurement mode, indicating low temperature, high temperature, VSAT, LSAT, low pressure, and high pressure.

Figure 4: Interface for Pressure and Temperature Measurement Mode.

5.2. Superheat and Subcooling Measurement

The device automatically calculates superheat (SH) and subcooling (SC) values based on the selected refrigerant and measured parameters.

Xetron LMG-10X display showing superheat and subcooling values, with a background of hot and cold elements.

Figure 5: Display showing Superheat and Subcooling measurements.

5.3. Pressure Hold Test Mode

To enter Pressure Hold Test mode, briefly press the MODO botón seguido do botón REPRODUCIR/PAUSA button from VAC mode. This mode allows you to monitor pressure changes over time.

Diagram illustrating the Xetron LMG-10X display in Pressure Hold Test mode, showing elapsed time, initial pressure, current pressure, and pressure difference.

Figure 6: Interface for Pressure Hold Test Mode.

5.4. Unit Settings and Auto Shutdown

The device allows for conversion of various measurement units and configuration of automatic shutdown settings.

Interface for setting temperature unit.

Figure 7: Temperature Unit Setting.

Interface for setting pressure unit.

Figure 8: Pressure Unit Setting.

Interface for automatic shutdown OFF setting.

Figure 9: Auto Shutdown OFF.

Interface for automatic shutdown ON setting.

Figure 10: Auto Shutdown ON.

6. Built-in Refrigerant Database

The Xetron LMG-10X comes with a comprehensive database of 88 types of refrigerants, allowing for accurate calculations and measurements across various systems.

List of 88 refrigerants supported by Xetron LMG-10X, including R113, R114, R134A, R410A, etc.

Figure 11: Partial list of supported refrigerants.

7. Mantemento

7.1. Limpeza

Limpe o dispositivo cun suave, damp pano. Non empregue produtos de limpeza abrasivos nin disolventes. Asegúrese de que o dispositivo estea seco antes de gardalo.

7.2. Almacenamento

Store the device in its carrying case in a cool, dry place when not in use. Remove batteries if storing for extended periods to prevent leakage.

8 Solución de problemas

ProblemaCausa posibleSolución
O dispositivo non se acende.Low or dead batteries; incorrectly inserted batteries.Substitúa as pilas; asegúrese de que a polaridade sexa correcta.
Lecturas inexactas.Probes not properly connected; incorrect refrigerant selected.Check probe connections; verify selected refrigerant matches system.
A pantalla está escura ou parpadea.Batería baixa.Substitúe as pilas.

9. Especificacións

10. Garantía e soporte

Xetron offers a one-year warranty for the LMG-10X Digital Manifold Gauge. For any questions or support needs, please contact Xetron customer service. We are committed to providing lifetime customer service.

For further assistance, please visit the official Xetron websitio web ou póñase en contacto cos seus canais de asistencia.

Documentos relacionados - XT-LMG-10X-EU

Preview Manual de usuario del controlador de temperatura inteligente Xetron STC-1000Pro
Manual de usuario para o controlador de temperatura dixital intelixente Xetron STC-1000Pro. Detalla as características, o funcionamento, a instalación e as especificacións para un control preciso da temperatura en aplicacións como a elaboración caseira de cervexa, acuarios e incubación.
Preview Manual do usuario da serie de controladores de temperatura intelixentes Xetron STC-1000Pro TH
Manual de usuario completo para a serie de controladores de temperatura intelixentes Xetron STC-1000Pro TH, que detalla as súas características, funcionamento, instalación e especificacións técnicas para un control preciso da temperatura e a humidade.
Preview ZES ZIMMER LMG450: 4-Channel Precision Power Meter for Energy Analysis
Explore the ZES ZIMMER LMG450, a versatile 4-channel precision power meter designed for motors, power electronics, and energy analysis. Features include a color graphics display, extensive measurement capabilities, and advanced functions for development and testing.
Preview Liga de Airsoft de Nova Zelandiaampionship Rules | NZAL Official Rulebook
Ch oficialampionship rules and regulations for the New Zealand Airsoft League (NZAL). Covers player classes, equipment, match structure, game play, safety, penalties, and conduct for competitive airsoft events.
Preview Manual do usuario dos rifles de aire comprimido con canón de apertura rápida Gamo 10X, 10X GEN2, 10X GEN3i
Manual de usuario completo para os rifles de aire comprimido con canón de apertura rápida Gamo 10X, 10X GEN2 e 10X GEN3i Quick-Shot, que abrangue a seguridade, o funcionamento, o mantemento e a resolución de problemas.
Preview Liga de Airsoft de Nova ZelandiaampRegras de ionship - Libro de regras oficial
Regras oficiais da Liga de Airsoft de Nova Zelandia (NZAL) Cap.ampeventos de competición, detallando as regulacións, as clases, o equipamento, a estrutura da competición, a seguridade e a conduta.