1. Introdución
The Elitech STC-1000HX is a versatile digital temperature controller designed for precise temperature management in various applications. It features a large display, switchable Fahrenheit and Celsius units, and two relay outputs for controlling both heating and cooling devices. This manual provides detailed instructions for installation, setup, operation, and maintenance to ensure optimal performance and longevity of your device.
Características principais:
- Wide temperature measurement and control range.
- Fahrenheit (℉) and Celsius (℃) switchable display.
- Two relay outputs for independent control of heating and cooling.
- Large, clear digital display for easy readability.
- Waterproof NTC sensor for reliable temperature detection.
- Sensor failure alarm function.

Imaxe 1.1: Fronte view of the Elitech STC-1000HX Digital Temperature Controller, showing the digital display and control buttons.
2. Información importante de seguridade
Please read and understand all safety instructions before installing or operating the STC-1000HX. Failure to follow these instructions may result in electric shock, fire, or damage to the device.
- Asegúrese de que a fonte de alimentación voltage matches the controller's requirements (220V).
- All wiring should be performed by a qualified electrician or knowledgeable individual.
- Desconecte a alimentación antes de realizar calquera cableado ou mantemento.
- Do not operate the controller in environments with excessive moisture or corrosive gases.
- Asegurar a posta a terra adecuada para evitar riscos eléctricos.
- Manteña o dispositivo lonxe dos nenos.
3. Produto rematadoview e Compoñentes
3.1 Product Dimensions and Display
The STC-1000HX features a compact design with a large, easy-to-read LED display. The front panel includes buttons for power, settings, and navigation.

Image 3.1: Elitech STC-1000HX showing key dimensions (71mm width, 66mm depth, 29mm height) and icons for cooling, heating, temperature unit selection, and sensor failure alarm.
3.2 Compoñentes incluídos
O paquete estándar inclúe:
- 1 x Elitech STC-1000HX Digital Temperature Controller
- 1 x NTC Waterproof Temperature Sensor (6.6 feet / IP67 rated)
- 1 x Manual de usuario

Image 3.2: The waterproof NTC temperature sensor, rated IP67, with a 6.6-foot cable, designed for accurate and reliable temperature measurement in various environments.
4. Guía de instalación
4.1 Diagrama de cableado
Carefully follow the wiring diagram below. Ensure all connections are secure and correctly matched to avoid damage to the controller or connected devices. Disconnect power before wiring.

Image 4.1: Wiring diagram for the STC-1000HX. Terminals 1 & 2 are for Cooling (10A/110VAC), 3 & 4 for Heating (10A/110VAC), 5 & 6 for the Temperature Sensor, and 7 & 8 for Power Supply (110VAC).
Instrucións de cableado:
- Connect the main power supply (110V AC) to terminals 7 (Neutral) and 8 (Live).
- Connect the cooling device to terminals 1 (Neutral) and 2 (Live).
- Connect the heating device to terminals 3 (Neutral) and 4 (Live).
- Connect the NTC temperature sensor to terminals 5 and 6. The sensor is non-polar, so connection order does not matter.
4.2 Montaxe
The STC-1000HX is designed for panel mounting. Ensure the cutout dimensions match the controller's size for a secure fit. Allow adequate ventilation around the unit.
5. Configuración e configuración
5.1 Encendido/apagado
Manteña premido o Poder botón () for 3 seconds to turn the controller ON or OFF.
5.2 Setting Temperature Parameters
To enter the parameter setting mode, press and hold the Establecer botón () for 3 seconds. Use the Up (
) e Abaixo (
) buttons to navigate through parameters and adjust values. Press the Establecer botón de novo para confirmar e saír.
Parámetros comúns:
- SP (Setpoint): A temperatura desexada.
- HD (Heating Differential): The temperature difference above the setpoint before heating activates.
- CD (Cooling Differential): The temperature difference below the setpoint before cooling activates.
- PT (Compressor Delay): Delay time for compressor protection.
- CF (Temperature Unit): Switch between Celsius (℃) and Fahrenheit (℉).
6. Instrucións de funcionamento
6.1 Cooling Mode Operation
When the measured temperature exceeds the setpoint plus the cooling differential, the cooling relay will activate, turning on the connected cooling device. The cooling relay will deactivate when the temperature drops to the setpoint.
6.2 Heating Mode Operation
When the measured temperature falls below the setpoint minus the heating differential, the heating relay will activate, turning on the connected heating device. The heating relay will deactivate when the temperature rises to the setpoint.

Image 6.1: The STC-1000HX supports both cooling and heating functions, each with a 10A relay capacity, indicated by snowflake and sun icons respectively.
6.3 Funcións de alarma
The controller includes a sensor failure alarm. If the sensor circuit is open or short-circuited, the display will show an error code (e.g., 'EE') and an audible alarm may sound. Replace the sensor if this occurs.
7. Menu Parameter Settings
To access and modify the advanced parameters, press and hold the Establecer button for 3 seconds. Use the Up/Down buttons to navigate and adjust values.
| Función | Establecer rango | Por defecto | Descrición |
|---|---|---|---|
| SP | -50 ℃ ~ 120 ℃ (-58 ℉ ~ 248 ℉) | 10℃ (50℉) | Punto de consigna de temperatura |
| HD | 0.1 ℃ ~ 10.0 ℃ (0.2 ℉ ~ 18.0 ℉) | 2.0℃ (3.6℉) | Diferencial de calefacción |
| CD | 0.1 ℃ ~ 10.0 ℃ (0.2 ℉ ~ 18.0 ℉) | 2.0℃ (3.6℉) | Diferencial de refrixeración |
| PT | 0 ~ 10 minutos | minutos 3 | Tempo de retardo do compresor |
| CF | C / F | C | Temperature Unit (Celsius/Fahrenheit) |
8. Guía de solución de problemas
Consulta a táboa seguinte para ver os problemas comúns e as súas posibles solucións.
| Problema | Causa posible | Solución |
|---|---|---|
| A pantalla mostra "EE" | Sensor error (open circuit or short circuit) | Check sensor wiring. Replace sensor if damaged. |
| O controlador non se acende | No power supply or incorrect wiring | Verify power connections to terminals 7 and 8. Check fuse if applicable. |
| A calefacción/refrixeración non se activa | Incorrect setpoint/differential, compressor delay active, faulty relay, or device | Check SP, HD, CD, and PT settings. Wait for compressor delay. Test connected heating/cooling device. Check wiring to terminals 1-4. |
| Lectura da temperatura imprecisa | Sensor placement, damaged sensor, or calibration issue | Ensure sensor is correctly placed and not exposed to direct heat/cold. Replace sensor if damaged. |
9. Especificacións técnicas
- Modelo: STC-1000HX
- Fonte de alimentación: 110 V CA, 50/60 Hz
- Rango de medición de temperatura: -50 ℃ a 120 ℃ (-58 ℉ a 248 ℉)
- Rango de control de temperatura: -50 ℃ a 120 ℃ (-58 ℉ a 248 ℉)
- Resolución: 0.1 ℃ / 0.1 ℉
- Precisión: ±1℃ (±2℉)
- Sensor: NTC sensor (1PC)
- Saída de retransmisión: 2 Relays (Cooling 10A/110VAC, Heating 10A/110VAC)
- Consumo de enerxía: <3 W
- Temperatura de funcionamento: -10 ℃ a 60 ℃ (14 ℉ a 140 ℉)
- Temperatura de almacenamento: -20 ℃ a 75 ℃ (-4 ℉ a 167 ℉)
- Humidade relativa: 20% a 85% (sen condensación)
- Tamaño do panel frontal: 71 mm x 29 mm
- Dimensións do produto (LxWxH): 7.1 x 6.6 x 2.9 cm
- Peso do artigo: 200 g
10. Mantemento
To ensure the longevity and accurate operation of your STC-1000HX controller, follow these maintenance guidelines:
- Limpeza: Gently wipe the controller's display and casinLimpe cun pano suave e seco. Non empregue produtos de limpeza abrasivos nin disolventes.
- Coidados do sensor: Periodically inspect the NTC sensor for any signs of damage or corrosion. Ensure it is clean and free from debris that could affect temperature readings.
- Condicións ambientais: Operate the controller within the specified temperature and humidity ranges to prevent damage.
11. Garantía e soporte
11.1 Información da garantía
Elitech products are covered by a limited warranty against defects in materials and workmanship. For specific warranty terms and conditions, please refer to the warranty card included with your product or visit the official Elitech websitio.
11.2 Atención ao cliente
If you encounter any issues or have questions regarding your Elitech STC-1000HX temperature controller, please contact Elitech customer support through their official websitio web ou a información de contacto que se inclúe na embalaxe do produto.