1. Introdución
This manual provides detailed instructions for the safe and effective operation of your Jaycar Digitech QC1938 100MHz Digital Oscilloscope. Please read this manual thoroughly before using the device to ensure proper setup, operation, and maintenance. Retain this manual for future reference.
2. Información de seguridade
Observe the following safety precautions to prevent injury and avoid damage to the instrument or any products connected to it.
- Fonte de enerxía: Connect the oscilloscope only to the power source specified in this manual.
- Conexión a terra: Ensure the instrument is properly grounded to prevent electric shock.
- Sondas: Use only probes supplied or recommended by the manufacturer. Ensure probes are rated for the voltage sendo medido.
- Ventilación: Non bloquee as aberturas de ventilación. Asegúrese de que haxa un fluxo de aire axeitado arredor do instrumento.
- Ambiente: Operate the oscilloscope in a dry environment. Avoid exposure to moisture, dust, or extreme temperatures.
- Servizo: Encomende calquera tarefa de mantemento a persoal de servizo cualificado. Non intente reparar o instrumento vostede mesmo.
3. Contido do paquete
Verifique que todos os elementos que se indican a continuación estean presentes no seu paquete:
- Jaycar Digitech QC1938 Digital Oscilloscope
- 10:1 Passive Probe with 1.5m lead
- 2 x BNC to Clip Test Leads
- Cable USB
- Poder eléctrico
- Manual de usuario (este documento)
4. Produto rematadoview
The Jaycar Digitech QC1938 is a 100MHz Digital Oscilloscope designed for precise electronic measurements. It features a 7-inch color LCD screen, two independent channels, and a built-in waveform generator.



Características principais:
- 7-inch TFT color LCD screen with 800 x 480 pixel resolution
- Two independent input channels
- 100MHz bandwidth and 1GSa/s samptaxa de ling
- 8M memory depth (single channel)
- Integrated 25MHz waveform generator (Sine, Square, Ramp, Exponential, Noise, DC)
- Auto scale function for automatic sine and square wave detection
- 14 trigger modes including Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, and IIC
- 5 serial protocol triggers and decodes: RS232/UART, I2C, SPI, CAN, and LIN
- Two 3-digit digital voltmeters and a 6-digit hardware frequency indicator
- 32 types of auto measurements with real-time statistics
- USB Host/Device interface for computer control and data storage
5. Configuración
5.1 Conexión de alimentación
- Connect the supplied power lead to the power input on the rear panel of the oscilloscope.
- Plug the other end of the power lead into a grounded AC power outlet.
- Press the power button on the front panel to turn on the oscilloscope.
5.2 Conexión da sonda
- Connect the BNC connector of the passive probe to either Channel 1 (CH1) or Channel 2 (CH2) input on the front panel.
- Attach the ground clip of the probe to the circuit's ground point.
- Connect the probe tip to the test point in your circuit.
- Ensure the probe's attenuation setting (e.g., 1X or 10X) matches the setting on the oscilloscope for accurate readings.
6. Instrucións de funcionamento
6.1 Funcionamento básico
- Auto Scale: Press the 'AUTO SET' button to automatically adjust vertical, horizontal, and trigger settings for a stable waveform display. This function detects sine and square waves automatically.
- Vertical Controls (VOLTS/DIV, POSITION): Use the VOLTS/DIV knobs to adjust the vertical scale (voltage per division) for each channel. The POSITION knobs shift the waveform vertically.
- Horizontal Controls (SEC/DIV, POSITION): Use the SEC/DIV knob to adjust the horizontal scale (time per division). The horizontal POSITION knob shifts the waveform horizontally.
- Nivel de activación: Adjust the 'TRIGGER LEVEL' knob to set the voltage level at which the oscilloscope captures a waveform.
6.2 Funcións avanzadas
- Xerador de formas de onda: Access the waveform generator menu to select and configure output waveforms such as Sine, Square, Ramp, Exponential, Noise, and DC. Connect the 'WAVE GEN' output to your circuit.
- Modos de activación: Utilize the 14 available trigger modes (Edge, Pulse, Video, Slope, Overtime, Window, Pattern, Interval, Under Amp, UART, LIN, CAN, SPI, IIC) to capture specific events. Select modes via the 'TRIGGER' menu.
- Serial Protocol Decoding: The oscilloscope supports decoding for RS232/UART, I2C, SPI, CAN, and LIN protocols. Configure these settings in the 'DECODE' menu to view decoded data.
- Medidas: The device offers 32 types of automatic measurements with real-time statistics (maximum, minimum, standard deviation, etc.). Access these via the 'MEASURE' menu.
- Conectividade USB: Connect a USB thumb drive to the USB Host port to save oscilloscope setups, waveforms, reference waveforms, CSV files, and images. The USB Device port allows for remote control from a computer using SCPI commands.
7. Mantemento
7.1 Limpeza
Para limpar o instrumento, use un pano suave dampened with a mild detergent solution. Do not use abrasive cleaners or solvents that could damage the casing or screen. Ensure the device is powered off and unplugged before cleaning.
7.2 Almacenamento
When not in use, store the oscilloscope in a dry, dust-free environment away from direct sunlight and extreme temperatures. Use the original packaging or a suitable case for protection during transport.
8 Solución de problemas
If you encounter issues with your oscilloscope, refer to the following common problems and solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| Sen poder | Power cable not connected; Power outlet faulty; Power button not pressed | Check power cable connection; Test power outlet; Press power button firmly |
| Non se mostra ningunha forma de onda | Probe not connected; Incorrect input channel selected; Vertical/Horizontal scale incorrect; Trigger level too high/low | Connect probe to CH1/CH2; Select correct channel; Adjust VOLTS/DIV and SEC/DIV; Adjust TRIGGER LEVEL or use 'AUTO SET' |
| Forma de onda inestable | Incorrect trigger settings; No stable trigger source | Adjust trigger level; Select appropriate trigger mode; Ensure a stable signal source |
| Unidade USB non recoñecida | USB drive formatted incorrectly; Drive not fully inserted | Ensure USB drive is FAT32 formatted; Re-insert USB drive firmly |
Se o problema persiste despois de intentar estas solucións, póñase en contacto co servizo de atención ao cliente.
9. Especificacións
| Parámetro | Especificación |
|---|---|
| Mostrar | LCD color TFT de 7 polgadas |
| Resolución | 800 x 480 píxeles |
| Tipo de visualización | Point, Vector |
| Canles | 2 |
| Ancho de banda | 100 MHz |
| Samptaxa de ling | Ata 1 GSa/s |
| Profundidade da memoria | 8M (single channel) |
| Rango Vertical | 2mV / div ~ 10V / div |
| Resolución vertical | 8 bit |
| Xerador de formas de onda | Sine, Square, Ramp, Exponential, Noise, DC |
| Interface | USB Host, USB Device |
| Peso | 1.9 kg |
| Dimensións (L x A x A) | 318 mm x 150 mm x 110 mm |
10. Garantía e soporte
Para obter información sobre a garantía e asistencia técnica, consulte a documentación proporcionada no momento da compra ou póñase en contacto co seu vendedor. Garde o comprobante de compra para reclamacións de garantía.