Introdución
The CDN Digital Probe Cooking, Cooling Thermometer, Smoker Oven Grill Candy Deep Frying, Multifunctional Thermometer/Timer/Clock (Model DTTC-W) is a versatile tool designed to assist in precise temperature monitoring for various cooking and cooling applications. This manual provides detailed instructions for setup, operation, maintenance, and troubleshooting to ensure optimal performance and longevity of your device.
Información de seguridade
- Always handle the stainless steel probe with care as it can become very hot during use. Use oven mitts or heat-resistant gloves when removing the probe from hot food or ovens.
- Do not immerse the main thermometer unit in water or any other liquid. The unit is not waterproof. Clean only the probe and cable.
- Ensure the probe cable is not pinched or damaged by oven doors or grill grates, as this can affect accuracy and damage the cable.
- Manteña o dispositivo fóra do alcance dos nenos.
- Non use o termómetro nun forno microondas.
- Only use the specified battery type (1 AAA).
Compoñentes
Your CDN DTTC-W package includes the following components:
- Digital Thermometer/Timer/Clock Unit
- Stainless Steel Probe with High-Heat Sensor Cable
- Clip de maceta
- 1 pila AAA (incluída)

Image: The CDN Digital Probe Thermometer DTTC-W unit, showing the main display, control buttons, the stainless steel probe, and the pot clip.
Configuración
- Instalación da batería:
Localiza o compartimento das pilas na parte traseira da unidade principal. Abre a tapa do compartimento e insire unha pila AAA, asegurándote de que a polaridade sexa correcta (+/-). Pecha a tapa con seguridade.
- Conexión da sonda:
Insert the plug of the stainless steel probe cable into the jack located on the side of the main unit. Ensure it is fully inserted for proper connection.

Imaxe: Primeiro plano view of the stainless steel probe and its high-heat sensor cable, ready for connection to the main unit.
- Colocación de unidades:
The DTTC-W offers two mounting options:
- Parte traseira magnética: The unit has magnetic strips on its back, allowing it to be securely attached to metal surfaces like a refrigerator door or oven exterior.
- Fold-out Stand: A hinge allows the unit to sit upright on a countertop or stovetop for easy viewing.

Image: The thermometer unit attached to an oven door via its magnetic back, demonstrating the magnetic mounting option.

Image: The thermometer unit standing upright on a countertop using its integrated fold-out stand.
Instrucións de funcionamento
The DTTC-W features a clear LED screen displaying time, current food temperature, and set temperature. Buttons are clearly marked for ease of use.
Modos de operación:
Preme o MODO button to cycle through the three main modes: Thermometer, Timer, and Clock.
1. Thermometer Mode:
- Medición de temperatura: Insert the stainless steel probe into the thickest part of the food, avoiding bone or gristle. The current internal temperature will be displayed on the screen.
- Setting Temperature Alert:
- Preme o ALERTA button. The set temperature will flash.
- Usa o UP e ABAIXO buttons to adjust the desired target temperature.
- Preme ALERTA de novo para confirmar a configuración.
- When the food reaches the set temperature, an alarm will sound. Press any button to silence the alarm.
- Fahrenheit/Celsius Selection: Use the switch on the back of the unit to toggle between Fahrenheit (°F) and Celsius (°C) temperature scales.
- Using the Pot Clip: For deep frying or candy making, attach the pot clip to the side of your saucepan. Insert the probe through the clip, ensuring the probe tip is submerged in the liquid but not touching the bottom of the pan.

Image: The pot clip securely attached to the rim of a saucepan, holding the probe in place for accurate temperature monitoring during cooking.
2. Timer Mode:
- Configuración do temporizador de conta atrás:
- Preme o HR e MIN buttons to set the desired countdown time.
- Preme INICIAR/PARAR para comezar a conta atrás.
- Para facer unha pausa, prema INICIAR/PARAR de novo. Prema de novo para continuar.
- Para borrar o temporizador, prema CLR.
- An alarm will sound when the timer reaches zero. Press any button to silence.
- Count-Up Timer:
From Timer mode, ensure the timer is set to 0:00. Press INICIAR/PARAR to begin counting up. Press INICIAR/PARAR to pause/resume, and CLR para reiniciar.
3. Clock Mode:
- Configuración do reloxo:
- In Clock mode, press and hold the MODO botón ata que os díxitos das horas parpadeen.
- Usa o HR e MIN buttons to set the hour and minute respectively.
- Preme MODO para confirmar cada configuración.
- The clock displays 12-hour or 24-hour time.

Image: The thermometer probe accurately measuring the internal temperature of a chicken roasting inside an oven.

Image: The thermometer probe inserted into chicken breasts cooking on a grill, demonstrating its use for outdoor cooking.
Mantemento
- Limpeza:
The stainless steel probe and cable can be cleaned with a damp cloth and mild detergent. Rinse thoroughly and dry immediately. The main unit should be wiped clean with a damp cloth only. Do not immerse the main unit in water.

Image: The thermometer unit and probe resting on a wooden cutting board, illustrating the ease of access for cleaning after use.
- Substitución da batería: Replace the AAA battery when the display dims or the unit stops functioning correctly.
- Almacenamento: Store the thermometer in a clean, dry place when not in use. Avoid extreme temperatures or direct sunlight.
Resolución de problemas
| Problema | Causa posible | Solución |
|---|---|---|
| Sen pantalla ou pantalla escura. | Batería esgotada ou mal instalada. | Substitúa a pila AAA, asegurándose de manter a polaridade correcta. |
| Lecturas de temperatura inexactas. | Probe not fully inserted, damaged probe/cable, or probe tip touching bone/pan. | Ensure probe is fully inserted. Check cable for damage. Reposition probe to avoid bone/pan. If issues persist, the probe may need replacement. |
| A alarma non soa. | Alarm volume too low (if adjustable, though this model doesn't specify), or alarm setting incorrect. | Verify alarm temperature is set correctly. Ensure the unit is not in a location where the sound is muffled. |
| Unit resets or freezes. | Batería baixa ou avaría interna. | Substitúa a batería. Se o problema persiste, póñase en contacto co servizo de atención ao cliente. |
Especificacións
- Rango de medición: 14 to 392°F / -10 to +200°C
- Intervalo do temporizador: Up to 24 hours by hr/min
- Lonxitude da sonda: 5.5 polgadas (14.0 cm)
- Lonxitude do cable do sensor: 3 pés (91.4 cm)
- Sensor Cable Heat Resistance: Ata 600 °F / 315 °C
- Fonte de enerxía: 1 x 1.5V AAA IEC LR03 Alkaline Battery (included)
- Tipo de visualización: LCD dixital
- Opcións de montaxe: Magnetic back, Fold-out stand
- Materiais: Stainless Steel probe, Plastic unit casing
- Dimensións do produto: 10.5 x 6 x 1.3 polgadas; 4 onzas (aproximadamente)
Garantía
The CDN Digital Probe Cooking Thermometer (DTTC-W) is covered by a two-year warranty against defects in materials and workmanship from the date of purchase. This warranty does not cover damage resulting from misuse, abuse, accident, or unauthorized alteration or repair. Please retain your proof of purchase for warranty claims.
Apoio
For technical assistance, warranty claims, or general inquiries, please contact CDN Customer Service. Refer to the official CDN websitio para obter a información de contacto máis actualizada.
Websitio: www.cdn-timeandtemp.com