KKnoon MH13

MH13 Digital Insulation Resistance Tester User Manual

Model: MH13 | Brand: KKnoon

1. Introdución

The KKnoon MH13 Digital Insulation Resistance Tester is a high-stability and reliable instrument designed for measuring insulation resistance, AC/DC voltage, and more. It features a large LCD display with backlight, auto-ranging capabilities, and data storage, making it suitable for various electrical testing applications.

This manual provides detailed instructions for the safe and effective operation, maintenance, and troubleshooting of your MH13 tester. Please read this manual thoroughly before use to ensure proper functionality and safety.

2. Información de seguridade

WARNING: Improper use of this instrument can cause damage, shock, injury, or death. Read and understand all safety information and operating instructions before use.

  • Always ensure the device is powered off and disconnected from any circuits before connecting or disconnecting test leads.
  • Non empregue o probador se parece estar danado ou funciona de forma anormal.
  • Observe todos os códigos de seguridade locais e nacionais.
  • Avoid touching the test leads or the circuit under test during high voltage medidas.
  • Asegúrese de que a batería estea instalada e substituída correctamente segundo o especificado.
  • The device indicates high voltage during testing; exercise extreme caution.

3. Produto rematadoview

MH13 Digital Insulation Resistance Tester front view

Figura 3.1: Fronte view of the MH13 Digital Insulation Resistance Tester, showing the LCD display, control buttons, and input terminals.

MH13 Digital Insulation Resistance Tester dimensions and button functions

Figura 3.2: detallada view of the MH13 tester, illustrating its dimensions and the functions of each button, including TEST, HOLD, SELECT, MEM READ, and PI/DAR.

3.1 Contido do paquete

Verifique que todos os elementos que se indican a continuación estean incluídos no seu paquete:

  • 1 x Insulation Resistance Tester (MH13)
  • 1 x Signal Shielding Wire
  • 2 x probas
  • 2 pinzas de cocodrilo
  • 1 x bolsa de almacenamento
  • 1 Manual de usuario (inglés)

4. Configuración

4.1 Instalación da batería

The MH13 tester requires 8 x 1.5V AA batteries (not included). To install the batteries:

  1. Localiza o compartimento da batería na parte traseira do dispositivo.
  2. Use un desaparafusador para abrir a tapa do compartimento da batería.
  3. Insira 8 pilas AA, asegurándose de polaridade correcta (+/-).
  4. Coloque a tapa do compartimento da batería e fíxaa co parafuso.

Note: The device features a low battery indication to remind you when to replace batteries.

4.2 Conexión dos cables de proba

Connect the test leads to the appropriate input terminals on the tester. For most measurements, the red lead connects to the "LINE" terminal and the black lead to the "EARTH" terminal. For specific measurements like AC/DC voltage, refer to the relevant operating instructions.

5. Instrucións de funcionamento

5.1 Encendido/apagado

Manteña premido o POTENCIA botón durante 2 segundos para acender ou apagar o dispositivo.

5.2 Medición da resistencia de illamento

This function is used to measure the insulation resistance of various electrical equipment and insulating materials.

MH13 Digital Insulation Resistance Tester measuring insulation resistance on a motor

Figure 5.1: The MH13 tester connected to a motor for insulation resistance measurement, demonstrating the high voltage output capability.

  1. Ensure the circuit under test is de-energized and safely isolated.
  2. Connect the test leads to the two ends of the component or circuit you wish to test.
  3. Seleccione o volume de saída desexadotage (250V, 500V, 1000V, 2000V, or 2500V) using the Up/Down arrow buttons.
  4. Preme o PROBA button to initiate the measurement. The red light on the TEST button will illuminate.
  5. The insulation resistance value will be displayed on the LCD.
  6. After the measurement, the device will automatically discharge the circuit. Do not touch the test leads until the discharge is complete.

Note: The device has a high voltage indication to alert users during testing.

5.3 AC/DC Voltage Medición

The MH13 can also measure AC and DC voltagdentro do rango de 10 V a 600 V.

MH13 Digital Insulation Resistance Tester measuring AC and DC voltage

Figure 5.2: Illustration of how to connect the test leads for measuring AC voltage (left) and DC voltage (right) using the MH13 tester.

  1. In the standby interface, short press the SELECCIONAR button to enter the AC voltage function. Press it again to switch to the DC voltage función.
  2. Adjust the gear to the ACV or DCV voltage gear for measurement.
  3. Insert the test lead plug into the appropriate terminals (AC and G for AC, DC and G for DC).
  4. O voltage reading will be displayed on the LCD.

5.4 Absorption Ratio (DAR) and Polarization Index (PI)

The MH13 supports the calculation of Absorption Ratio (DAR) and Polarization Index (PI), which are crucial for assessing the quality of insulation.

MH13 Digital Insulation Resistance Tester Absorption Ratio (DAR) explanation

Figure 5.3: Explanation of Absorption Ratio (DAR) measurement, showing 15-second and 1-minute insulation resistance readings and the calculation formula.

MH13 Digital Insulation Resistance Tester Polarization Index (PI) explanation

Figure 5.4: Explanation of Polarization Index (PI) measurement, showing 1-minute and 10-minute insulation resistance readings and the calculation formula.

To perform DAR/PI tests:

  1. Set up for insulation resistance measurement as described in Section 5.2.
  2. Preme o PI/DAR button to initiate the test. The device will automatically compute and display the DAR and PI values based on timed measurements.
  3. Refer to the judgment standards provided in the product documentation for interpreting the results.

5.5 Data Hold and Storage

The MH13 can store up to 100 sets of measured insulation resistance values.

MH13 Digital Insulation Resistance Tester data storage display

Figure 5.5: The display showing multiple stored data sets, indicating the device's 100-set data storage capability.

  • Retención de datos: During a measurement, single press the ATENCIÓN botón para conxelar a lectura actual na pantalla. Prema de novo para soltala.
  • Almacenamento de datos: Despois dunha medición, prema o botón LECTURA MEM button to save the data.
  • View Stored Data: Preme o LECTURA MEM button to enter data browsing mode. Use the Up/Down arrow buttons to navigate through stored data groups.
  • Delete Stored Data: Refer to the full manual for instructions on deleting stored data, if applicable.

5.6 Signal Shielding for Measurement Accuracy

To minimize errors caused by "word jumping" phenomena in measurements, especially with sensitive insulation tests, utilize the signal shielding wire.

MH13 Digital Insulation Resistance Tester with signal shielding wire connected

Figure 5.6: The MH13 tester connected with a signal shielding wire, demonstrating how to reduce measurement errors by connecting the inner jack to the cable shell.

When a serious word jumping phenomenon occurs, insert the signal shielding wire's inner jack into the "G" (Guard) terminal. Connect the other end of the shielding wire to the cable shell or the inner insulation of the core to eliminate the error.

6. Mantemento

6.1 Limpeza

Wipe the device with a dry, soft cloth. Do not use abrasive cleaners or solvents. Ensure no liquids enter the device.

6.2 Almacenamento

When not in use for extended periods, remove the batteries to prevent leakage. Store the tester in its provided storage bag in a cool, dry place, away from direct sunlight and extreme temperatures.

MH13 Digital Insulation Resistance Tester with anti-drop silicone case

Figure 6.1: The MH13 tester protected by its anti-drop silicone case, highlighting its durable design for outdoor use and protection against damage.

The device is designed with a durable anti-drop silicone case, offering protection against accidental drops and impacts.

7 Solución de problemas

ProblemaCausa posibleSolución
O dispositivo non se acende.Pilas baixas ou gastadas; instalación incorrecta da pila.Substitúa as pilas por outras novas; asegúrese de manter a polaridade correcta.
"OL" or "Out of Range" displayed during measurement.Resistance is higher than the maximum range; open circuit.Verify circuit continuity; ensure proper connection of test leads.
Lecturas imprecisas ou fluctuantes.Poor test lead connection; external interference; dirty terminals; "word jumping" phenomenon.Ensure secure connections; use signal shielding wire; clean terminals; move away from strong electromagnetic fields.
Vol. Altotage warning remains after test.Circuit not fully discharged.Wait for automatic discharge to complete. Do not touch leads until warning clears.

8. Especificacións

ParámetroValor
Vol. De saídatage250V / 500V / 1000V / 2000V / 2500V
Rango de resistencia de illamento1 MΩ ~ 200 GΩ
Vol. ACtage Alcance10V ~ 600V
DC Voltage Alcance10V ~ 600V
Máx. Mostrar2000 contas
Almacenamento de datos100 conxuntos
RangoRango automático
Temperatura de funcionamento0-35 °C
Temperatura de almacenamento-10~50°C
Fonte de alimentación8 * 1.5V AA battery (NOT included)
Tamaño do elemento180 * 140 * 70 mm / 7.09 * 5.51 * 2.76 polgadas
Peso do elemento640 g / 22.58 oz

9. Garantía e soporte

For warranty information, technical support, or service inquiries, please refer to the official KKnoon website or contact their customer service directly. Details are typically provided in the full product manual or on the manufacturer's official channels.

Documentos relacionados - MH13

Preview Manual do probador de resistencia de illamento ANENG MH13
Manual de usuario completo para o comprobador de resistencia de illamento da serie ANENG MH13. Abarca as directrices de seguridade, as características do produto, as especificacións técnicas, os procedementos operativos para a resistencia de illamento e a tensión de CA/CC.tagProbas electrónicas, xestión de datos e substitución de baterías. Deseñado para mantemento, reparación e verificación eléctrica.
Preview Manual do usuario do comprobador de resistencia de illamento da serie ANENG de 1000 V/2500 V/5000 V
Manual de usuario completo para os probadores de resistencia de illamento ANENG das series 1000 V, 2500 V e 5000 V, que abrangue a seguridade, o funcionamento, as especificacións técnicas e os procedementos de medición de equipos eléctricos.
Preview Probador de resistencia de illamento ANENG MH13: especificacións técnicas e características
Especificacións detalladas, características e explicacións das medicións para o probador de resistencia de illamento ANENG MH13, incluíndo probas de índice de polarización (PI) e relación de absorción (DAR). Abarca voltaxes CA/CC.tagMedición electrónica, accesorios do produto e guía operativa.
Preview Tableau de Correspondance FACOM : Anciennes et Nouvelles Références Outils
Consultez le tableau de correspondance FACOM pour trouver les nouvelles références de vos outils FACOM à partir des anciennes références. Ce guide référence de nombreux produits FACOM.