Opengear CM8116

Opengear CM8100 Console Server User Manual

Modelo: CM8116

Introdución

This manual provides instructions for the installation, operation, and maintenance of the Opengear CM8100 Console Server. The CM8100 series is designed to provide secure out-of-band management for network and server infrastructure, enabling remote access and control even during primary network outages.

Key features of the CM8100 Console Server include:

  • 16, 32, or 48 port serial console server with Smart Out-of-Band™ capabilities.
  • Support for Data Center and Enterprise Network automation with Python and Docker.
  • Embedded physical security via TPM 2.0 module.
  • Dual power supplies for redundancy and independent monitoring.
  • Integrated environmental temperature monitoring.

Configuración e instalación

This section guides you through the physical installation and initial setup of your CM8100 Console Server.

Desembalaxe do dispositivo

Carefully unpack all components from the box. Verify that all items listed in the "What's in the Box" section are present and undamaged.

Opengear CM8100 Console Server front view

Imaxe: Fronte view of the Opengear CM8100 Console Server, showing the red and black chassis, Opengear logo, model number, and dual power inlets on the right side.

Montaxe en rack

The CM8100 Console Server is designed for standard 19-inch rack installation.

  1. Attach the two rack ears to the sides of the console server using the provided M4 screws.
  2. Secure the console server into the rack using the four M5x15mm rack screws and M5mm caged nuts. Ensure the device is level and securely fastened.

Conexión de alimentación

The CM8100 features dual power supplies for redundancy.

  1. Connect the two A/C power cables to the power inlets on the rear of the console server.
  2. Connect the other ends of the power cables to independent power sources for redundancy.
  3. Verify that the power indicator LEDs on the front panel illuminate, indicating successful power-up.

Conexión de rede

Connect the console server to your network for management access.

  1. Connect an Ethernet cable from your network switch to the primary network port on the console server.
  2. (Optional) Connect a second Ethernet cable to the secondary network port for network redundancy.

Conexión de porto serie

Connect your managed devices (servers, network devices) to the serial ports on the CM8100.

  1. Identify the serial ports on the rear of the console server.
  2. Use appropriate serial cables (e.g., the provided CAT5 patch cable with DB9F-RJ45 rollover serial adapter) to connect your devices to the CM8100 serial ports.
  3. Note the port numbers for future configuration.
Traseira view of Opengear CM8100 Console Server showing network and serial ports

Imaxe: Traseira view of the Opengear CM8100 Console Server, displaying various network and serial console ports, along with dual power supply connections.

Operación

This section covers basic operation and initial access to the CM8100 Console Server.

Acceso Inicial

Access the console server for initial configuration via a direct serial connection or network connection.

Serial Console Access

  1. Connect a computer to the console server's dedicated console port using a serial cable.
  2. Configure your terminal emulation software (e.g., PuTTY, Tera Term) with the following settings: 115200 baud, 8 data bits, no parity, 1 stop bit, no flow control.
  3. Power on the CM8100. The boot process will display on your terminal.
  4. Log in using the default credentials (refer to the Quick Start Guide for default username and password).

Network Access (Web Interface)

Once the device has an IP address (either DHCP assigned or manually configured via serial console), you can access the web interface.

  1. Abrir a web browser and enter the IP address of the CM8100.
  2. Inicia sesión usando as túas credenciais.
  3. Dende o web interface, you can configure serial ports, network settings, user accounts, and other system parameters.

Xestión de dispositivos conectados

The CM8100 allows you to connect to the console of your attached devices.

  • Acceso á consola serie: Dende o web interface or command-line interface (CLI), select the desired serial port to establish a connection to the attached device.
  • Out-of-Band Management: Utilize the Smart OOB™ features to access and manage devices even when the primary network is down.

Mantemento

Regular maintenance ensures optimal performance and longevity of your CM8100 Console Server.

Actualizacións de firmware

Periodically check the Opengear website for firmware updates. Keeping the firmware current provides new features, bug fixes, and security enhancements.

  1. Download the latest firmware image from the official Opengear support portal.
  2. Access the CM8100 web interface.
  3. Navigate to the firmware update section (typically under System > Firmware).
  4. Follow the on-screen instructions to upload and install the new firmware. Do not power off the device during the update process.

Limpeza

Keep the console server clean to prevent dust buildup, which can affect cooling.

  • Use un pano suave e seco para limpar o exterior do dispositivo.
  • Asegúrese de que as aberturas de ventilación estean libres de obstáculos.
  • Do not use liquid cleaners directly on the device.

Consideracións ambientais

Ensure the operating environment meets the recommended conditions.

  • Maintain proper airflow around the device.
  • Keep the device within specified temperature and humidity ranges.

Resolución de problemas

This section provides solutions to common issues you might encounter with the CM8100 Console Server.

Sen Poder

  • Síntoma: Power indicator LEDs are off, device does not respond.
  • Solución: Verify that both A/C power cables are securely connected to the device and to active power outlets. Check power sources and circuit breakers.

Non se pode acceder Web Interface

  • Síntoma: Web browser cannot connect to the CM8100 IP address.
  • Solución:
    1. Verify the console server has power and is running.
    2. Confirm the network cable is properly connected to an active network port.
    3. Check the IP address configuration of the CM8100 (via serial console if necessary).
    4. Ensure your computer is on the same network or has a route to the CM8100's IP address.
    5. Temporarily disable any firewalls on your computer to rule out interference.

No Serial Console Connection to Managed Device

  • Síntoma: Unable to establish a serial connection to a device connected to the CM8100.
  • Solución:
    1. Verify the serial cable connection between the CM8100 port and the managed device.
    2. Ensure the correct serial cable type (e.g., rollover, straight-through) is used for the specific device.
    3. Check the serial port configuration on the CM8100 (baud rate, data bits, parity, stop bits, flow control) matches the settings of the managed device.
    4. Confirm the managed device is powered on and functioning correctly.

Especificacións

Característica Detalle
Marca Opengear
Serie CM8100 Console Server
Número de modelo CM8116
Peso do elemento 8.63 libras
Dimensións do produto (LxWxH) 19.5 x 16.5 x 3.5 polgadas
Fabricante Opengear
Primeiro dispoñible 16 de febreiro de 2023

O que hai na caixa

The following items are included with your Opengear CM8100 Console Server:

  • CM8100 Console Server
  • Kit de montaxe en rack
  • 2 x Rack Ears with Six M4 Screws
  • 4 x M5mm Caged Nuts
  • 4 x M5x15mm Rack Screws
  • 1 x CAT5 Patch Cable 6'
  • 1 x DB9F-RJ45 Rollover Serial Adapter
  • 2 x A/C Power Cables
  • Guía de inicio rápido
  • Lighthouse Insert

Documentos relacionados - CM8116

Preview Opengear CM7116, CM7132, CM7148 Quick Start Guide
Quick start guide for Opengear CM7116, CM7132, and CM7148 console servers, covering installation, hardware connection, initial setup, serial and USB device configuration, user management, and accessing device consoles.
Preview Guía do usuario do servidor da consola de Opengear
Esta guía do usuario ofrece instrucións completas para instalar, operar e xestionar os servidores de consola Opengear, incluídos modelos como o ACM7000, o IM7200 e o CM7100. Abarca a configuración do sistema, a configuración da rede, as funcións de seguridade e a resolución de problemas para a xestión da infraestrutura de TI.
Preview Opengear Operations Manager OM12xx/OM22xx Quick Start Guide
This Quick Start Guide provides basic installation and configuration instructions for the Opengear Operations Manager OM12xx and OM22xx series devices, including setup, login, and basic configuration steps.
Preview Guía de inicio rápido de Opengear IM7200: instalación e configuración
Unha guía concisa para instalar, configurar e operar o Xestor de infraestrutura Opengear IM7200, que abrangue o contido do kit, o acendido, a conexión de rede e a configuración básica.
Preview Manual do usuario de Opengear: Xestión de centros de datos e sitios remotos
Este completo manual de usuario de Opengear detalla as características e capacidades das súas liñas de produtos avanzadas deseñadas para a xestión de centros de datos e sitios remotos. Ofrece instrucións esenciais para os usuarios responsables de avaliar, instalar, operar ou xestionar dispositivos Opengear, que abarcan a instalación, a configuración, a creación de redes, a seguridade e as características avanzadas.
Preview Manual do usuario de Opengear: Guía completa de servidores de consola e pasarelas
Explora o Manual do usuario de Opengear para obter instrucións detalladas sobre a instalación, o funcionamento e a xestión dos servidores de consola de Opengear, os xestores de sitios remotos e os xestores de infraestrutura. Obtén información sobre as características, as configuracións e a resolución de problemas para varios modelos de Opengear.