Introdución

This manual provides detailed instructions for the installation, operation, and maintenance of your OREiN Bathroom Exhaust Fan with LED Light, Model OL17004. Please read this manual thoroughly before installation and use to ensure proper function and safety. Keep this manual for future reference.

OREiN Bathroom Exhaust Fan with LED Light, showing the fan unit with its white light cover and the three selectable color temperatures (3000K, 4000K, 5000K) at the bottom.

Image: OREiN Bathroom Exhaust Fan with LED Light, showcasing its design and adjustable color temperature options.

Información de seguridade

AVISO: Para reducir o risco de incendio, descarga eléctrica ou lesións ás persoas, observe o seguinte:

  • Instale esta unidade só do xeito previsto polo fabricante. Se ten algunha dúbida, póñase en contacto co fabricante.
  • Antes de realizar tarefas de mantemento ou limpeza, desconecte a alimentación no panel de servizo e bloquee os medios de desconexión do servizo para evitar que se conecte a alimentación accidentalmente. Cando os medios de desconexión do servizo non se poidan bloquear, fixe con seguridade un dispositivo de aviso visible, como un tag, ao panel de servizos.
  • Os traballos de instalación e cableado eléctrico deben ser realizados por persoas cualificadas de acordo con todos os códigos e normas aplicables, incluídos os códigos e normas de construción con clasificación contra incendios.
  • Precísase aire suficiente para a combustión e a evacuación adecuada dos gases a través da cheminea (cheminea) dos equipos de combustión para evitar o retrotraxe. Siga as directrices do fabricante de equipos de calefacción e as normas de seguridade, como as publicadas pola Asociación Nacional de Protección contra Incendios (NFPA) e a Sociedade Americana de Enxeñeiros de Calefacción, Refrigeración e Aire Acondicionado (ASHRAE) e as autoridades de códigos locais.
  • Ao cortar ou perforar a parede ou o teito, non dane o cableado eléctrico nin outras utilidades ocultas.
  • Os ventiladores con conductos deben estar sempre ventilados ao aire libre.
  • This unit is not intended for use in kitchens.
  • Non use este ventilador con ningún dispositivo de control de velocidade de estado sólido.

Contido do paquete

Comprobe que todos os compoñentes estean presentes antes de comezar a instalación:

  • OREiN Bathroom Exhaust Fan Unit (Housing with Motor and Duct Connector)
  • Tapa de luz LED
  • Soporte de montaxe
  • Wire Connectors (Wago-style)
  • Parafusos de montaxe
Explotou view of OREiN Bathroom Exhaust Fan components, showing the fan housing, mounting bracket, and light cover, along with small parts like wire connectors and screws.

Image: Components included with the OREiN Bathroom Exhaust Fan.

Especificacións

CaracterísticaEspecificación
MarcaOREiN
Nome do modeloOL17004
Capacidade de caudal de aire110 CFM (pés cúbicos por minuto)
Nivel de ruído2.0 Sons
Wattage27 Watts (Total, Fan + Light)
Saída de luz1500 lúmenes
Temperatura de cor (CCT)3000K (Soft White), 4000K (Bright White), 5000K (Daylight) Selectable
Luz nocturna2200 mil
Voltage120 voltios
Housing Dimensions (L x W x H)7.68" x 7.55" x 6.42"
Light Cover Size9.8" x 9.8"
Ceiling Opening Size8.11" x 7.48"
Tamaño do conector do conduto4 polgadas (redondo)
CertificaciónsETL, FCC Listed
Detailed product dimensions for the OREiN Bathroom Exhaust Fan, showing the housing, light cover, and required ceiling opening sizes in inches.

Image: Product dimensions and required ceiling opening for installation.

Configuración e instalación

Ferramentas necesarias: Screwdriver, Wire Strippers, Drill, Measuring Tape, Utility Knife, Safety Glasses, Gloves.

Importante: Ensure power is OFF at the circuit breaker before starting installation.

  1. Preparación da abertura no teito: Create a ceiling opening of 8.11" x 7.48". Ensure there is sufficient space above the ceiling for the fan housing (7.68" x 7.55" x 6.42").
  2. Montar a carcasa:
    • Attach the mounting bracket to the ceiling joists. The bracket is designed for easy installation between joists.
    • Slide the fan housing into the mounting bracket. Secure the housing to the bracket using the provided screws or by nailing/screwing directly to the joist if preferred.
  3. Conectar a canalización: Connect a 4-inch round duct to the fan's duct connector. Ensure the duct is securely fastened and sealed to prevent air leakage. Vent the ductwork to the outdoors.
  4. Cableado eléctrico:
    • Route the electrical supply wires (120V AC) to the fan housing.
    • Connect the fan's wires to the household wiring using the provided wire connectors. Follow the wiring diagram below.
    • Asegurar a correcta posta a terra.
    • The fan and light can be wired to separate switches for independent control. The LED light wires cannot be connected to a dimmer switch.
  5. Instalar a tapa de luz: Once wiring is complete and secured, attach the LED light cover to the fan housing. Ensure it clicks into place or is securely fastened according to the design.
Wiring diagram for the OREiN Bathroom Exhaust Fan with Light, showing connections for ground, fan switch, and light switch to a 120V AC line. Also shows the fan's install size of 8.11 by 7.48 inches.

Image: Electrical wiring diagram and installation dimensions.

Instrucións de funcionamento

Funcionamento do ventilador

The exhaust fan operates at 110 CFM to effectively remove moisture and odors from your bathroom. It features a low noise level of 2.0 sones for quiet performance.

  • Turn on the dedicated fan switch to activate the exhaust fan.
  • Turn off the fan switch to deactivate the fan.
OREiN Bathroom Exhaust Fan installed in a ceiling, highlighting its features: 110 CFM airflow, less than 2.0 Sones noise level, 26W power consumption, and 3 CCT options with 1500 lumens.

Image: Installed fan highlighting key performance metrics.

Funcionamento da luz LED

The integrated LED light offers adjustable color temperature and a nightlight function.

  • Axuste da temperatura da cor (CCT):

    The fan features a toggle switch on the back of the unit (accessible before final installation of the light cover) to select your desired color temperature: 3000K (Soft White), 4000K (Bright White), or 5000K (Daylight). Set this switch to your preferred CCT before installing the light cover.

    Tres examples of the OREiN Bathroom Exhaust Fan's LED light at different color temperatures: 3000K (warm white), 4000K (neutral white), and 5000K (cool daylight), all at 1500 lumens. A small toggle switch is shown for CCT selection.

    Image: Demonstrates the three selectable color temperatures of the LED light.

  • Modo de luz nocturna:

    The fan includes a 2200K nightlight feature. To activate or cycle through the nightlight mode, quickly turn the light switch OFF and then ON again within 2 seconds. This action will switch between the main light and the nightlight mode.

    A bathroom scene illuminated by the OREiN Bathroom Exhaust Fan's 2200K nightlight, showing a soft, warm glow. Text indicates that cycling the light switch within 2 seconds changes to nightlight mode.

    Image: The 2200K nightlight function in a bathroom setting.

Mantemento

Un mantemento regular garante un rendemento óptimo e unha maior duración do seu extractor de aire.

  • Cleaning the Light Cover:
    • Turn off power at the circuit breaker before cleaning.
    • Carefully remove the light cover.
    • Wipe the light cover with a soft, damp pano. Non use produtos de limpeza abrasivos.
    • Allow the cover to dry completely before reattaching.
  • Cleaning the Fan Grille/Housing:
    • With the light cover removed and power off, gently vacuum or wipe away any dust or debris from the fan grille and accessible parts of the housing.
    • Do not spray water directly into the fan motor or electrical components.
  • Fonte de luz LED: The LED light source is integrated and designed for long life. It is not user-replaceable. If the LED light fails, contact customer support.

Resolución de problemas

ProblemaCausa posibleSolución
O ventilador non funciona.Sen subministración eléctrica; cableado solto; interruptor avariado.Check circuit breaker. Ensure all wire connections are secure. Test switch functionality.
A luz non acende.No power supply; loose wiring; faulty switch; CCT toggle switch not set.Check circuit breaker. Ensure all wire connections are secure. Test switch functionality. Verify the CCT toggle switch on the fan unit is set to a valid position (3000K, 4000K, or 5000K).
O ventilador fai ruído ou vibra excesivamente.Montaxe solta; residuos nas aspas do ventilador; problema co motor.Ensure fan housing is securely mounted. Turn off power and inspect fan blades for obstructions. If noise persists, contact customer support.
Poor ventilation/steam not clearing.Blocked ductwork; improper duct installation; fan motor issue.Check ductwork for kinks or blockages. Ensure duct is properly sealed and vented outdoors. Verify fan motor is running at full speed.
Light color temperature is incorrect or stuck.CCT toggle switch not set correctly.Turn off power, remove light cover, and adjust the CCT toggle switch on the fan unit to your desired setting. Reinstall cover and restore power.
Nightlight function not working.Incorrect switching sequence.Ensure you are cycling the light switch OFF and ON again within 2 seconds to activate the nightlight mode.

Garantía e Soporte

For warranty information or technical assistance, please contact OREiN customer support. Refer to your purchase documentation for specific warranty terms and conditions.

Información de contacto:

  • For support, please visit the OREiN store on Amazon: OREiN Amazon Store
  • Alternatively, search for "OREiN" online to find official contact channels.

Additional resources, including a detailed Installation Manual and User Guide, may be available in PDF format: