1. Introdución
The Elitech CLD-100 Refrigerant Leak Detector is an advanced tool designed for precise detection of halogenated refrigerants, including CFCs, HCFCs, and HFCs. This manual provides comprehensive instructions for the proper setup, operation, and maintenance of your CLD-100 detector to ensure optimal performance and longevity.
2. Características clave
- Upgraded Corona Sensor: Features a traditional corona sensor with an updated analog circuit for fast detection of R11, R22, R134A, R404a, R410A, and all halogenated refrigerants, including HFCs, CFCs, HCFCs, and blends.
- Rapid Response: Offers a quick 6-second preheating time and instantaneous response to refrigerant leaks.
- Sensibilidade axustable: Provides 6 adjustable sensitivity levels, with a maximum sensitivity of 0.21 oz/yr, allowing for precise leak identification.
- Sonda flexible: Equipped with an 8.26-inch flexible probe for easy access to difficult and hard-to-reach areas.
- Audible & Visual Alarms: Direct status indication with clear audible and visual leakage alarms.
- Dual Color Battery Indicators: Ofrece unha indicación clara do estado da batería.
- Integrated UV Light: Includes a UV light feature to assist in detecting refrigerant leaks that contain UV dye, often visible as oil spotting.

Figure 2.1: Elitech CLD-100 highlighting its main features.
3. Contido do paquete
Ao abrir o paquete, comprobe que todos os elementos enumerados a continuación estean presentes e en bo estado:
- 1 x Elitech CLD-100 Refrigerant Leak Detector
- 1 x bolsa de transporte
- 1 x Manual de usuario (este documento)
- 1 x UV Light attachment

Figure 3.1: Contents included in the Elitech CLD-100 package.
4. Produto rematadoview
Familiarize yourself with the main components of the Elitech CLD-100 detector:

Figure 4.1: Main components of the CLD-100 detector.
- Sonda flexible: Allows for reaching confined spaces.
- Luz UV: Aids in detecting leaks with fluorescent dye.
- Consello do sensor: The primary detection point for refrigerants.
- Luz indicadora: Provides visual feedback on leak detection and battery status.
- Zumbador: Emits an audible alarm when a leak is detected.
- Power On/Off & Sensitivity Adjustment Switch: Rotary knob to power on/off and select sensitivity levels.
- Compartimento de batería: Located at the bottom, holds 4 AAA batteries (not included).
5. Configuración
Before first use, install the batteries:
- Locate the battery compartment cover at the bottom of the detector.
- Open the cover and insert 4 AAA batteries, ensuring correct polarity (+/-).
- Peche ben a tapa do compartimento da batería.
Nota: as pilas non están incluídas no paquete.

Figure 5.1: Elitech CLD-100 ready for use.
6. Instrucións de funcionamento
Follow these steps to operate your Elitech CLD-100 detector:
- Encendido: Turn the Power On/Off & Sensitivity Adjustment Switch to the "ON" position. The detector will emit a continuous beeping sound, indicating it is preheating.
- Prequecemento: Allow approximately 6 seconds for the detector to preheat and stabilize. The beeping sound will become steady.
- Axustar a sensibilidade: Rotate the switch to select the desired sensitivity level (1-6). For maximum sensitivity, it is recommended to turn the device on outdoors, away from any potential refrigerant sources, to allow it to calibrate to the ambient environment.
- Detección de fugas:
- Point the flexible probe towards the area suspected of a leak.
- Move the probe slowly (approximately 1 inch per second) around the suspected leak points, such as AC system high-side and low-side lines, condenser coils, and compressor gaskets.
- If a refrigerant leak is detected, the beeping sound will increase in frequency, and the indicator light will change, signaling the presence of a leak. The closer the probe is to the leak, the faster the beeping will become.
- Función de luz UV: The UV light feature can be activated by sliding the light switch on the probe.
- The light has two settings: a regular flashlight mode for illuminating dark work areas and a UV light mode.
- When a refrigerant leak occurs, it often involves oil mixed with the refrigerant. If a UV dye has been added to the system, the UV light will illuminate any oil spotting, helping to pinpoint the exact leak location.
- Apagado: When finished, turn the Power On/Off & Sensitivity Adjustment Switch to the "OFF" position.

Figure 6.1: Using the CLD-100 for quick leak detection.

Figure 6.2: The CLD-100 is capable of detecting a wide range of halogenated refrigerants.
7. Especificacións

Figure 7.1: Key specifications of the CLD-100 detector.
| Atributo | Valor |
|---|---|
| Marca | Elitech |
| Modelo | CLD-100UV |
| Estilo | Industrial |
| Fonte de enerxía | Funciona con pilas (requírense 4 pilas AAA, non incluídas) |
| Cor | Laranxa |
| Dimensións do produto (P x A x A) | 8.66" x 2.36" x 2.36" |
| Peso do elemento | 3.53 onzas (100 gramos) |
| Material | Plástico |
| Sensibilidade máxima | 0.21 oz/yr |
| Tempo de prequecemento | 6 segundos |
| Tempo de resposta | Instantánea |
| Temperatura de traballo | 0 °C - 52 °C |
| Duración da batería | ~50 horas |
| País de Orixe | China |
8. Mantemento
To ensure the longevity and accuracy of your Elitech CLD-100, follow these maintenance guidelines:
- Limpeza: Wipe the detector with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Coidados do sensor: The sensor tip is a delicate component. Avoid physical damage and keep it clean. Over time, the sensor may wear out or become unstable, requiring replacement for optimal performance.
- Substitución da batería: Replace batteries when the dual color battery indicators show low power. Always use fresh AAA batteries.
- Almacenamento: Store the detector in its provided carry bag in a cool, dry place when not in use.
9 Solución de problemas
If you encounter issues with your CLD-100, refer to the following common problems and solutions:
| Problema | Causa posible | Solución |
|---|---|---|
| O detector non se acende. | Baterías gastadas ou instaladas incorrectamente. | Check battery polarity and replace with new AAA batteries. |
| Constant beeping or false positives. | High sensitivity setting in a contaminated environment; sensor needs calibration or replacement. | Turn on the device in a clean, outdoor environment for proper calibration. Reduce sensitivity if necessary. If problem persists, consider sensor replacement. |
| No detection or low sensitivity. | Low battery; sensor tip is dirty or worn out; sensitivity setting too low. | Replace batteries. Clean the sensor tip. Increase sensitivity. If still no detection, the sensor may need replacement. |
| A luz ultravioleta non funciona. | Light switch not activated; low battery. | Ensure the light switch is fully engaged. Check and replace batteries if needed. |
For further assistance, please contact Elitech customer support.
10. Garantía e soporte
Elitech stands behind the quality of its products. For any technical assistance, warranty claims, or product inquiries, please utilize our dedicated support channels:
- US Technician Support: Available 24/7 via Email and Phone.
- Please refer to the product packaging or Elitech's official websitio web para obter datos de contacto específicos.
For more information about Elitech and our range of products, visit the Tenda Elitech.