UNI-T UT181A

UNI-T UT181A True RMS Datalogging Multimeter Instruction Manual

Modelo: UT181A | Marca: UNI-T

1. Produto rematadoview

The UNI-T UT181A is an industrial-grade True RMS Datalogging Multimeter designed for high-precision measurements in various professional applications. It features advanced functionalities such as VFC (Voltage Frequency Converter) and Low-Pass Filtering, making it suitable for complex electrical systems. Its robust design ensures reliability in demanding environments.

UNI-T UT181A Multimeter Front View

Figura 1: Fronte view of the UNI-T UT181A True RMS Datalogging Multimeter, showcasing its large color TFT LCD and control buttons.

2. Características clave

3. Que hai na caixa

The UNI-T UT181A package includes the following items:

UNI-T UT181A Multimeter and Accessories

Figure 2: The UNI-T UT181A multimeter displayed with its complete set of accessories, including test leads, cables, temperature probes, and carrying case.

4. Configuración

4.1 Instalación da batería

The UT181A is powered by a rechargeable Li-ion battery. Ensure the battery is properly installed before first use. The battery compartment is located on the rear of the device.

  1. Localiza a tapa do compartimento da batería na parte traseira do multímetro.
  2. Use un desaparafusador para abrir o compartimento da batería.
  3. Insert the Li-ion battery, ensuring correct polarity.
  4. Peche ben a tapa do compartimento da batería.
UNI-T UT181A Battery Compartment

Imaxe 3: Primeiro plano view of the battery compartment on the back of the UT181A, showing battery and fuse specifications.

4.2 Carga da batería

Connect the provided charging cable to the multimeter and a suitable power adapter. The multimeter cannot be used while charging.

4.3 PC and Bluetooth Connectivity

The UT181A supports both USB and Bluetooth communication for data transfer and remote monitoring. The USB interface allows synchronization with a Windows operating system for data logging and analysis. An optional Bluetooth adapter (UT-D07A) can be used for wireless connectivity to increase measurement safety by allowing remote operation.

Video 1: Demonstration of the UNI-T UT181A multimeter's features, including its display, measurement functions, USB connectivity for data logging, and optional Bluetooth adapter for remote operation.

5. Instrucións de funcionamento

5.1 Encendido/apagado

Press and hold the power button (usually marked with a circle and a vertical line) for approximately 3 seconds to turn the multimeter on or off. The display will show a boot-up sequence.

5.2 Selección de funcións

Rotate the central rotary dial to select the desired measurement function. Use the blue "SELECT" button to toggle between different modes within a single rotary switch position (e.g., AC/DC voltage, resistance/continuity).

5.3 Funcións de medición

5.4 Data Logging and Analysis

The UT181A can log up to 20,000 data points. Connect the multimeter to a PC via USB or Bluetooth (with optional adapter) to transfer and analyze logged data using the provided software. The software allows for trend capture and data comparison.

UNI-T UT181A Multimeter in use for electrical measurements

Figure 4: The UT181A multimeter actively measuring electrical parameters in an industrial setting.

6. Mantemento

6.1 Limpeza

Regularly clean the multimeter's casing cun suave, damp cloth. Do not use abrasive cleaners or solvents. Keep the display clean and free from scratches.

6.2 Coidado coa batería

To prolong battery life, charge the Li-ion battery regularly and avoid fully discharging it. If storing the multimeter for an extended period, ensure the battery is partially charged.

6.3 Substitución de fusibles

If the multimeter fails to measure current or shows incorrect readings in current modes, the fuse may need replacement. Refer to the specifications for the correct fuse type (e.g., F10A H 1000V, F0.8A H 1000V). Always disconnect test leads and power before opening the fuse compartment.

7 Solución de problemas

7.1 Problemas de comunicación

If the multimeter fails to establish communication with a PC or mobile device via USB or Bluetooth, ensure the communication settings are correctly configured in the multimeter's setup menu. Some firmware versions may require re-enabling communication after each power cycle. Verify that the correct drivers are installed on your PC.

7.2 Lecturas inexactas

Check the battery level, ensure test leads are properly connected, and verify that the correct measurement function and range are selected. For current measurements, inspect the fuses. If issues persist, consult the detailed troubleshooting section in the full user manual or contact UNI-T support.

8. Especificacións

ParámetroRange (UT181A)Precisión
DC Voltage (V)60mV/600mV/6V/60V/600V/1000V±(0.025 %+5)
Vol. ACtage (V)60mV/600mV/6V/60V/600V/1000V±(0.6 %+30)
Corrente DC (A)600µA/6000µA/60mA/600mA/10A±(0.08 %+10)
Corrente CA (A)600µA/6000µA/60mA/600mA/10A±(0.6 %+20)
Resistencia (Ω)600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ±(0.05 %+2)
Capacitancia (F)6nF/60nF/600nF/6µF/60µF/600µF/6mF/60mF±(2 %+5)
Frecuencia (Hz)10 Hz ~ 60 MHz±(0.01 %+5)
Temperatura (°C)-40 °C ~ 1000 °C±(1 %+30)
Temperatura (°F)-40 ° F ~ 1832 ° F±(1.5 %+50)
Número de visualizacións60000
Rexistro de datos20000
InterfaceUSB, Bluetooth
Clasificación IPIP65
Batería2000 mAh Li-ion
Dimensións6.5 x 4.33 x 4.72 polgadas
Peso1.32 libras (0.6 kg)
UNI-T UT181A Detailed Specifications Table

Figure 5: A detailed table outlining the electrical specifications and features of the UNI-T UT181A multimeter.

9. Garantía e soporte

The UNI-T UT181A comes with certifications including CE, UKCA, and cETLus, ensuring compliance with international safety and quality standards. UNI-Trend, the manufacturer, is committed to providing high-quality products and offers spare part availability for 4 years in the EU. For technical support, warranty claims, or service, please contact your local distributor or the official UNI-T support channels.

Manufacturer: UNI-Trend

Certifications: CE, ISO 9001, RoHS, UKCA, cETLus

EU Spare Part Availability Duration: 4 Years

Documentos relacionados - UT181A

Preview Manual do usuario do multímetro dixital UNI-T UT181A: guía de instalación, funcionamento e software
Manual de usuario completo para o multímetro de rexistro de datos de verdadeiro valor RMS UNI-T UT181A. Abarca a instalación, a configuración do software, o funcionamento, o rexistro de datos e os modos de medición. Inclúe os requisitos do sistema e os detalles da interface do software.
Preview UNI-T UT181A True-RMS Data Logging Digital Multimeter Operating Manual
Operating manual for the UNI-T UT181A True-RMS Data Logging Digital Multimeter, detailing features, functions, and usage instructions for professional testing applications.
Preview Manual de funcionamento do multímetro intelixente UNI-T UT181A
Manual de funcionamento completo para o multímetro intelixente portátil de rango automático con valor RMS verdadeiro UNI-T UT181A, que abrangue as especificacións, as operacións de medición, o mantemento e as precaucións de seguridade.
Preview Bedienungsanleitung Zangen-Multimeter UT 210E
Umfassende Bedienungsanleitung für das UNI-T UT 210E True-RMS Zangenmultimeter von reichelt elektronik. Erfahren Sie mehr über die Funktionen zur Messung von Spannung, Strom, Widerstand, Durchgang und Kapazität, sowie Sicherheitshinweise und technische Daten.
Preview Manual do usuario do multímetro dixital UNI-T UT60EU/UT60BT: guía completa
Manual de usuario detallado para os multímetros dixitais UNI-T UT60EU e UT60BT. Abarca as características, a seguridade, o funcionamento, as especificacións técnicas e o mantemento para obter medicións eléctricas precisas.
Preview Manual de funcionamento do UNI-T UT803: Guía do multímetro dixital
Manual de funcionamento completo para o multímetro dixital de mesa UNI-T UT803 True RMS, que abrangue a seguridade, as especificacións, os procedementos de medición e o mantemento.