Test Boy TV 456

Installation Tester TV 456 User Manual

Model: TV 456 | Brand: Testboy

1. Introdución

The Testboy TV 456 is a comprehensive installation tester designed for professional testing of electrical systems. It is capable of performing a wide range of measurements including loop resistance, mains internal resistance, short circuit current, low ohm and continuity, insulation, RCD/FI tests for various types (A, AC, B, B+, F), and RCD/FI for electric car charging stations (6mA DC). The device features a 3.5-inch TFT color display and supports standard-compliant test protocols via included software. Its robust design and intuitive interface make it an essential tool for electrical professionals.

2. Información de seguridade

Always observe the following safety precautions when operating the Testboy TV 456:

3. Produto rematadoview

The Testboy TV 456 features a user-friendly layout with a clear display and tactile buttons for easy operation.

Testboy TV 456 Installation Tester with display showing RCD auto test results and various buttons.

Figura 1: Fronte view of the Testboy TV 456 Installation Tester. The device features a central color display, navigation buttons on the left, function buttons (MEM, COM, HLP) on the top left, and a rotary selector switch on the right for selecting measurement modes (RPE, MΩ, LINE, LOOP, RCD, V). A large red "TEST" button is prominent on the left side.

3.1. Controles e pantalla

4. Configuración

4.1. Carga inicial

Before first use, ensure the Testboy TV 456 is fully charged. Connect the provided charging column adapter to the device and a suitable power source. The battery indicator on the display will show the charging status.

4.2. Acendido/apagado

Manteña premido o Botón de encendido (marked with a circle and vertical line) located on the top right of the device to turn it on or off. The display will illuminate upon successful power-on.

4.3. Language and Basic Settings

Upon first power-on, you may be prompted to select a language. Use the navigation buttons to select your preferred language and confirm. Further settings such as date, time, and display brightness can be adjusted via the Botón de configuración (marked with a gear icon).

5. Instrucións de funcionamento

The Testboy TV 456 offers various test options. Select the desired test mode using the rotary selector switch.

5.1. Loop Resistance Measurement

  1. Turn the rotary selector switch to LOOP.
  2. Connect the test leads to the circuit according to the on-screen diagram.
  3. Preme o PROBA botón para iniciar la medición.
  4. The loop resistance value will be displayed.

5.2. Medición da resistencia de illamento

  1. Turn the rotary selector switch to .
  2. Ensure the circuit is de-energized and safely isolated.
  3. Connect the test leads to the conductors to be tested.
  4. Preme o PROBA button. The device will apply a test voltage and display the insulation resistance.

5.3. RCD/FI Testing

The device supports RCD/FI testing for types A, AC, B, B+, F, and 6mA DC for EV charging stations.

  1. Turn the rotary selector switch to RCD.
  2. Use the navigation buttons to select the RCD type (A, AC, B, B+, F, 6mA DC) and desired test current/multiplier (e.g., x1, x5).
  3. Conecte os cables de proba ao circuíto RCD.
  4. Preme o PROBA button. The device will perform the test and display the tripping time and current.

5.4. Data Logging and Software

The Testboy TV 456 allows for saving test results. Press the MEM button to access memory functions. Saved data can be transferred to a computer using the COM button and the provided software (Excel platform) for generating standard-compliant test protocols.

6. Mantemento

6.1. Limpeza

Limpa o dispositivo regularmente cun pano suave eamp pano. Non empregue produtos de limpeza abrasivos nin disolventes. Asegúrese de que o dispositivo estea apagado e desconectado de calquera fonte de alimentación antes de limpalo.

6.2. Coidado da batería

To prolong battery life, avoid fully discharging the battery frequently. Store the device in a cool, dry place when not in use for extended periods. Recharge the battery periodically if stored for a long time.

6.3. Calibración

For accurate measurements, it is recommended to have the Testboy TV 456 calibrated by an authorized service center periodically, typically annually or as required by local regulations.

7 Solución de problemas

ProblemaCausa posibleSolución
O dispositivo non se acende.Batería baixa ou esgotada.Charge the device using the provided adapter.
Lecturas inexactas.Dirty test leads or probes; device needs calibration.Clean test leads; contact service center for calibration.
A pantalla está en branco ou conxelada.Software error; extreme temperature.Perform a hard reset (refer to specific reset procedure in full manual); move to a suitable operating temperature.
Non se poden gardar os resultados da proba.Memory full; incorrect operation.Delete old data from memory; refer to "Data Logging" section.

8. Especificacións

9. Garantía e soporte

9.1. Información da garantía

The Testboy TV 456 comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Testboy websitio web para obter termos e condicións detallados relativos á cobertura e duración da garantía.

9.2. Soporte técnico

For technical assistance, troubleshooting beyond this manual, or service inquiries, please contact Testboy customer support. Contact information can typically be found on the manufacturer's official websitio web ou na embalaxe do produto.

Documentos relacionados - TV 456

Preview Testboy® 15: Bedienungsanleitung und Sicherheitshinweise
Erfahren Sie mehr über das Testboy® 15 Magnetfeld-Messgerät. Diese Anleitung enthält wichtige Informationen zur Bedienung, Sicherheitshinweisen und technischen Daten des Geräts von Testboy GmbH.
Preview Testboy TV 510 PV Module Tester - User Manual and Specifications
Comprehensive user manual and technical specifications for the Testboy TV 510 PV module tester, covering safety instructions, operation, and disposal.
Preview Testboy 113: Bedienungsanleitung, Sicherheitshinweise und technische Daten
Die offizielle Bedienungsanleitung für das Testboy 113 Messgerät. Erfahren Sie mehr über berührungslose Spannungsprüfung, Sicherheitshinweise, technische Daten und die fachgerechte Anwendung dieses electricischen Prüfgeräts von Testboy GmbH.
Preview Testboy® 110: Bedienungsanleitung für berührungslosen Spannungsprüfer
Umfassende Bedienungsanleitung für den Testboy® 110, einen berührungslosen Spannungsprüfer. Enthält Sicherheitshinweise, Bedienung, Technische Daten und Anwendungsrichtlinien.
Preview Testboy 40 Simple Two-Pole Voltage Tester - Specifications and Features
Detailed information on the Testboy 40 Simple, a robust and user-friendly two-pole voltage tester with LED display, 12-690V AC/DC range, continuity testing up to 500 kΩ, and single-pole phase detection. Features CAT IV 300V / CAT III 600V rating and IP54 protection.
Preview Testboy® 15: Präziser Magnetfelddetektor - Bedienungsanleitung
Die Bedienungsanleitung for den Testboy® 15, un detector Magnetfelddetektor de Testboy GmbH. Erfahren Sie mehr über Funktionen, Sicherheitshinweise und technische Daten.